Standard double acting, single rod version of the CQ2 compact cylinder. The CQ2 is available in bore sizes from 4mm to 100mm. It comes standard with male or female piston rod threads. It is possible to mount auto switches on any of the 4 surfaces.
Double Acting, Single Rod Series (N)CQ2 Ordering Information How to Order Port thread type Mounting threads Switch 12 to 25 M thread Rc NPT G One Touch Notes 4,5) Nil Metric North American Nil N Solid state switch (see page 181 for details) M9 TN TF F 32 to 100 A9 Reed switch Magnet Note 4) Bore sizes available for air-hydro type are 20 to 100. Note 5) TF is not available for air-hydro type
SB, counterbore depth SC P .C.D.R (Mounting hole) Auto switch mounting groove positions (4 locations) MHS3-100D MHS3-125D 10 10 10 10 40 40 40 40 5 6.4 5 10 6.4 13 90 12 5 15 7 90 (mm) I G 63 84 FZ 10 12 FX 59 74 FY 54 68 CA 18 23.5 EC 28 30 EO 40 46 DC 66 82 DO 78 98 M 4 6 B 134 166 K 15 21 AC 6 8 J 38 52 AA 96 122 AB 90 114 NA 34 40 L +0.036 0 +0.036 0 NB Model MHS3-100D MHS3-125D CB 30.6
Description Stroke range Bore size Stroke range 32 to 100 101 to 299 Part no.: CDQ2A50-166DCZ-XC89 CDQ2A50-175DCZ-XC89 with 9 mm width spacer inside The B dimension is 235.5 mm.
0 Finger assembly MH-TA3201 MH-TA4001 MH-TA5001 MH-TA6301 Lever assembly MH-TA3202 MH-TA4002 MH-TA5002 MH-TA6302 32, 50 Link parts assembly MH-TA3203 MH-TA4003 MH-TA5003 MH-TA6303 40, 63 Compact cylinder CDQ2A32-15DZ CDQ2A40-15DZ CDQ2A50-20DZ CDQ2A63-20DZ For finger assembly, lever assembly, order 2 pieces per one unit. Replacement part/Grease pack part no.