The HRLE is a temperature control device featuring two independent cooling channels in one package. This thermo chiller is designed to cool the optical head and oscillator of a laser processing system. Considerabe space savings can be realized compared to a two chiller solution. All operation can be managed from a single touch panel. Compared to the HRL, the HRLE targets medium-sized 3-
Cooling Capacity: 090 (9.5 kW Air/ 11.0kW Water), Cooling Method: A (Air-cooled Refrigeration), Power Supply: 40 [3-phase 380 to 415VAC (50/60 Hz); 3-phase 460 to 480VAC (60 Hz)], Option: CMP (Compressor Inverter + Applicable to DI Water Piping + with Pump Inverter)
Thermo Chiller, HRS090 AND LARGER CAPACITIES, O88, 148.00000 lb
HRLE090-A-20/40 HRLE090-A-20/40 [50 Hz] [60 Hz] 12 12 Ambient temperature 32C Ambient temperature 32C 10 10 Cooling capacity [kW] Cooling capacity [kW] 8 8 Ambient temperature 40C 6 6 Ambient temperature 40C 4 4 Ambient temperature 45C 2 2 Ambient temperature 45C 0 0 15 20 25 Circulating fluid temperature [C] 15 20 25 Circulating fluid temperature [C] * The cooling capacity is the sum of
Cooling Capacity: 090 (9.5 kW Air/ 11.0kW Water), Cooling Method: A (Air-cooled Refrigeration), Power Supply: 40 [3-phase 380 to 415VAC (50/60 Hz); 3-phase 460 to 480VAC (60 Hz)]
Cooling Capacity: 9.5 kW Air/ 11.0kW Water, Cooling Method: Air-cooled Refrigeration, Power Supply: 40 [3-phase 380 to 415VAC (50/60 Hz); 3-phase 460 to 480VAC (60 Hz)], Option: -