Series MHM is a magnetic gripper that can be used in place of vacuum cups or grippers when holding a metallic workpiece. Auto switches can be mounted on 2 surfaces. Expanded mounting options include body tapped, lateral, and central.
&WEB -14- 3. 5mm B B B A A () A B 0 A B A mm B Nm A B MHM-16D1 2 10 6 1.5 5 MHM-25D1 3 14 8 5.2 5 MHM-32D1 3 14 8 5.2 5 MHM-50D1 5 24 17 42 5 -15- D(mm) L(mm) MHM-16D1 14 25 MHM-25D1 19 37 MHM-32D1 19 43 MHM-50D1 30 63 4. 2 1 n /WEB Best Pneumatics m () 0.5 ( ) 3 (NPN) 3 (PNP) IC 2 3 (NPN) IC 3 (PNP) 2 PLC 2 3 (PNP) 3 (NPN) IC (2 ) 2 1 0.5mM9NW 1m M M9NWM 3m L M9NWL 5m
Action Double acting Fluid Air Operating pressure 0.25 to 0.6 MPa Ambient and fluid temperature 10 to 60C (No freezing) Holding force (Workpiece thickness: 0.6 mm) Symbol Holding force Model 1 80 N MHM-A3201-1-X6400 2 50 N MHM-A3201-2-X6400 3 30 N MHM-A3201-3-X6400 MHM-32D1-X6400 80 N MHM-32D2-X6400 50 N MHM-32D3-X6400 30 N Residual holding force 0.3 N or less Lubrication Non-lube Weight
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ DNote 1) When using the 2-color indicator type, please make the setting so that the indicator is lit in red to ensure the detection at the proper position of the air gripper.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model MHS MHL2-10D MHL2-10D1 MHL2-10D2 MHL2-16D MHL2-16D1 MHL2-16D2 MHL2-20D MHL2-20D1 MHL2-20D2 MHL2-25D MHL2-25D1 MHL2-25D2 MHL2-32D MHL2-32D1 MHL2-32D2 MHL2-40D MHL2-40D1 MHL2-40D2 280 345 425 585 795 935 1025 1495 1690 1690 2560 2775 2905 3820 4655