PF2M7 is a digital flow sensor compatible with air, nitrogen, argon or carbon dioxide. PF2M7 refreshes the legacy PFM7 with several enhancements. The thermal sensor is protected in a bypass flow path to reduce contact with moisture and contaminants, avoiding accuracy deterioration and damage. Dimensions and weight have been reduced, especially beneficial when installed on moving tooling.
A fire or explosion can result. Only dry air, N2, CO2 and Ar are applicable. Do not use the product in a place where static electricity is a problem. Otherwise it can cause failure or malfunction of the system.
Similar items in stock.
A 2 to 200 L/min flow range option has been added. A rear ported type has been added. A flow adjustment valve (0.05 to 5 L/min) has been added.
Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: N2 (NPT1/4), Output Specification: E (Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V)
Rated Flow Range: 1 to 100 L/min, Flow Adjustment Valve: With Flow Adjustment Valve, Straight, Port Size: NPT1/4, Output Specification: Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V, Lead Wire: -, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -