Membrane air dryer series IDG is available in a single unit or combination unit style. IDG/M models combine a mist separator and micro mist separator with a single unit. IDG/V models combine a regulator with the IDG/M model. Options available include one-touch fitting exhaust of purge air. If purged air is not exhausted around membrane air dryer, air is exhausted with tubing away from its
Dew point checker (Option : S) Air inlet port * Outlet port in case of Option R Body Purge air outlet port Case Front Fig 2.1 Names of parts -3- 2. Installations and Operations 2. Installations and Operations: Piping Air Supply Warning a.
y y e u e r t u r i u Drain Drain Drain Component Parts No.
M5 Port size M5 x 0.8 R 1/8 R 1/4 R 3/8 R 1/2 10-32 UNF NPT 1/8 NPT 1/4 NPT 3/8 NPT 1/2 Type 01 02 03 04 U10/32 N01 N02 N03 N04 Elbow Universal 2 3 Universal type Applicable tubing O.D.
Metric sizes Inch sizes Model Port size 1/8 12 10 8 5/16 3/8 6 1/4 5/32 3/16 4 ASD230F-M5 ASD330F-01 ASD430F-02 ASD530F-02 ASD530F-03 ASD630F-04 M5 x 0.8 R 1/8 R 1/4 R 1/4 R 3/8 R 1/2 ASD230F-U10/32 ASD330F-N01 ASD430F-N02 ASD530F-N02 ASD530F-N03 ASD630F-N04 10-32UNF NPT1/8 NPT1/4 NPT1/4 NPT3/8 NPT1/2 Specifications Proof pressure JIS symbol 1.5MPa (218psi) 1MPa (145psi) 0.1MPa (14.5psi