IFW is a mechanical switch for the detection and confirmation of liquid flow. The flow body houses a diaphragm responsive to flow rate. A connected rod and lever mechanism triggers a micro switch at a manually adjustable set point. An optiional light, either neon (VAC) or LED (VDC), can indicate operation. Compatible liquids must be non-corrosive to the brass and copper alloy wetted parts
Response time selections: 20ms, 160ms, 640ms, 1000ms, 2000ms 16-2-50 7 Series ISE70/75/75H Digital Pressure Switch For Air/For General Fluids Dimensions ISE70 75 75H / / 39 9 34 MPa ZSE ISE Lead wire with M12 connector (5m) straight OUT1 PSE U P DOWN 70 SET Z I SE3 14.5 PS Z I SE1 2 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588
N.O. q IFW50--75/76 e Color of lead wire Black Symbol Contact q w Power supply (Common) w Red Terminal (Relay terminal) 24 VDC Gray e Power supply (Light terminal) N.O. N.C. q IFW50--85/86 e Color of lead wire Black Symbol Contact q w Power supply (Common) White Terminal (Relay terminal) w 24 VDC Gray e Power supply (Light terminal) N.C. N.O.