Lead 3: LEY25C 30 Regeneration Option Models Area where the regeneration option is required.
Lead 3: LEY25C 30 Regeneration Option Models Area where the regeneration option is required.
Selection Example Operating conditions W Work load: 16 [kg] Speed: 300 [mm/s] 40 Acceleration/Deceleration: 5000 [mm/s2] Lead 3: LEY25C Stroke: 300 [mm] 30 Work load [kg] Workpiece mounting condition: Vertical upward downward transfer 20 Lead 6: LEY25B 16 Step 1 Check the work loadspeed.