The X5 option, available for the LEY series in sizes 25 and 32, is a dust and drip proof specification equivalent to IP65. For DC motor models, the spec is achieved by enclosing the motor in a sealed aluminum cover with a special cable connector, and pairing the rod with a scraper and lub-retainer. Additionally, the body extrusion includes a vent hole and fitting to balance internal pressure
Similar items in stock.
[mm] 100 1000 70 10 75 LEY u L = 50 mm Max. speed = Over 200 mm/s i L = 100 mm Max. speed = Over 200 mm/s LES 10 10 Load mass m [kg] Load mass m [kg] LEYG32M LEYG32M LEPY LEPS LEYG32M LEYG32M LEYG25M LEYG25M 1 1 LER LEYG25M LEYG25M LEH 0.1 0.1 LEY -X5 Stroke [mm] 100 1000 70 10 75 Stroke [mm] 100 1000 70 10 75 11LEFS Horizontal Mounting, Ball Bushing Bearing o L = 50 mm Max. speed = 200
0 300 200 400 100 500 600 Speed [mm/s] Speed [mm/s] LEPY LEPS LEY32m LEY32m for acceleration/deceleration: 2000 mm/s2 LER 90 50 80 Lead 4: LEY32C LEH 40 42 Horizontal work load [kg] Vertical work load [kg] 70 Lead 4: LEY32C LEY -X5 60 Lead 8: LEY32B 30 50 11LEFS 40 20 21 Lead 8: LEY32B 30 11LEJS Lead 16: LEY32A 20 10 Lead 16: LEY32A 10 25A0 0 0 300 200 400 100 500 600 0 300 200 400 100 500
: 2000 mm/s2 90 50 Lead 4: LEY32C 80 Lead 4: LEY32C 40 43 Horizontal work load [kg] 70 Vertical work load [kg] Lead 8: LEY32B 60 30 40 45 50 Lead 8: LEY32B 22 Lead 16: LEY32A 20 30 11 20 10 Lead 16: LEY32A 10 0 0 0 300 200 400 100 500 600 0 300 200 400 100 500 600 Speed [mm/s] Speed [mm/s] LEY40m LEY40m for acceleration/deceleration: 2000 mm/s2 100 60 Lead 4: LEY40C Lead 4: LEY40C 90 53 Horizontal
Lead 6: LEY25B 300 Force [N] LEH 200 LEY -X5 100 11LEFS Lead 12: LEY25A Step 2 Check the lateral load on the rod end.