The X8 option is a dust-proof and water-jet-proof specification equivalent to IP67. This spec is achieved with the addition of several unique features above the standard LEY. The motor is sealed within an aluminum cover, fitted with M-type metal cable connectors. The rod passes through a scraper and employs a lubrication retainer to prevent oil film washout. Futher, grease supply holes
Similar items in stock.
Symbol 1 Piping connection parts: Stainless steel 304 -X8 Specifications Model LFE1-X8 LFE2-X8 LFE3-X8 Fluid contact materials PPS, FKM, Stainless steel 304 Weight (Body)*1 Integrated display type Approx. 380 g Approx. 430 g Approx. 620 g Approx. 800 g Remote type sensor unit Approx. 375 g Approx. 425 g Approx. 615 g Approx. 795 g *1 When options are used, add the weight of the optional parts
Setting range: 1-8 CC-Link setting Occupied area Number of registrable Operation Number of Bit area Word area RWr/RWw Mode CC-Link Ver Extended cyclic occupied units RX/RY stations 1 15 1.10 x1 2 64/64 8/8 2 15 1.10 x1 4 128/128 16/16 3 15 2.00 x8 2 384/384 64/64 4 15 2.00 x8 4 896/896 128/128 5 31 2.00 x8 2 384/384 64/64 6 31 2.00 x8 4 896/896 128/128 7 63 2.00 x8 4 896/896 128/128 8 127
Extended cyclic occupied units RX/RY stations 1 15 1.10 x1 2 64/64 8/8 2 15 1.10 x1 4 128/128 16/16 3 15 2.00 x8 2 384/384 64/64 4 15 2.00 x8 4 896/896 128/128 5 31 2.00 x8 2 384/384 64/64 6 31 2.00 x8 4 896/896 128/128 7 63 2.00 x8 4 896/896 128/128 8 127 2.00 x8 4 896/896 128/128 * The last register of the bit area (16 bits) cannot be used as it is allocated for the system area.