Note 2) The data for l/min (ANR) refers to the conditions of 20C, 1 atm. pressure and relative humidity of 65%. Note 3) Install a circuit breaker with sensitivity of 30mA.
(Coil temperature: 20C, at rated voltage, without surge suppressor) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
(Coil temperature: 20C, at rated voltage, without surge voltage suppressor.) Made to Order Specifications (For details, refer to page 3-6-11.)
Membrane Dyer Series IDG Standard specifications/Single style (standard dew point 20C (4F)) Model Standard dew point 20C IDG5 IDG10 IDG20 IDG30 IDG50 Fluid Compressed air Macromolecular membrane dryers that act like filters Range of operating conditions Standard performance conditions Inlet air pressure MPa (psi) 0.3 to 0.85 (43 to 123) 0.3 to 1.0 (43 to 145) Inlet air temperature C (F) Note
Membrane Dyer Series IDG Standard specifications/Single style (standard dew point 20C) Model Standard dew point 20C IDG5 IDG10 IDG20 IDG30 IDG50 Fluid Compressed air Macromolecular membrane dryers that act like filters Range of operating conditions Standard performance conditions Inlet air pressure MPa 0.3 to 0.85 0.3 to 1.0 Inlet air temperature C Note 1) 5 to 55 Ambient temperature C 5
Flow rate conversion Normal condition: 0C, 101.3 kPa, dry air Standard condition: 20C, 101.3 kPa, 65%RH (ANR) Switchable between these conditions.
44.3 32.8 12 20.9 64 AS42 1FE-04-10SK 21 47.9 33.6 10 18.5 103 AS-FP 17 24 R 1/2 51.5 56.5 58.8 63.8 24.5 28.6 AS42 1FE-04-12SK 22 49.5 35.2 12 20.9 105 Note 1) Reference dimensions Note 2) Reference dimensions of R thread after installation.
Reach Vacuump. 11 Vacuum Break Flow Rate Characteristics p. 11 Constructionp. 12 How to Order Replacement Partsp. 13 Dimensionsp. 15 Multistage Ejector ZL3/ZL6 Series How to Orderp. 19 Ejector Specificationsp. 20 Supply Valve/Release Valve Specifications p. 20 Pressure Gauge Specificationsp. 20 Vacuum Pressure Switch Specificationsp. 21 Weightp. 21 Internal Circuits and Wiring Examplesp. 22
(mm) 2 x 1.2 Fluid Air, Water Max. operating pressure (at 20C) 0.8MPa Burst prssure Refer to pressure characteristics curve.
27 Refrigerated air dryer Body panel: White 1 (Munsell 10Y8/0.5) Base: Gray 2 (Munsell 10Y5/0.5) Coating color Auto drain Applicable air compressor output (Guide) In the case of a screw type (kW) 0.75 1.5 2.2 3.7 5.5 7.5 11 Note 1) The data for l/min (ANR) is under the conditions of 20C, 1 atmospheric pressure and relative humidity of 65%..
Number of arranged elements 4 7 9 18 22 Symbol Number of arranged elements 29 34 37 53 83 04 07 09 18 22 29 34 37 53 83 Symbol Nominal filtration accuracy (m) Note) Nominal filtration accuracy (m) 0.5 1 2 5 10 20 40 Symbol Nominal filtration accuracy (m) 50 70 74 75 100 105 120 X50 001 002 005 010 020 040 050 070 074 075 100 105 120 Symbol Element length Element length L250 L500 (L250 x 2
Note 2) The data for l/min (ANR) refers to the conditions of 20C, 1 atm. pressure and relative humidity of 65%. Note 3) Install a circuit breaker with sensitivity of 30mA.
Number of arranged elements 4 7 9 18 22 Symbol Number of arranged elements 29 34 37 53 83 04 07 09 18 22 29 34 37 53 83 Symbol Nominal filtration accuracy (m) Note) Nominal filtration accuracy (m) 0.5 1 2 5 10 20 40 Symbol Nominal filtration accuracy (m) 50 70 74 75 100 105 120 X50 001 002 005 010 020 040 050 070 074 075 100 105 120 Symbol Element length Element length L250 L500 (L250 x 2
Low temperature operation Unless otherwise indicated in each valve's specifications, the valve can be used at temperatures as low as 20C, but take measures to prevent freezing or solidification of drainage and moisture, etc. Selection Warning 1. Air quality 1) Use clean air.
28 33.5 29 28 39 35 46.0 8 19 12 44.5 22 60.0 10 22 10 12 (81) (96) 81 113 24 25.7 25 16 Reference dimensions after R thread installation.
13 31 100 214.5 22 53.5 75, 100 125.5 192.5 214.5 125.5 192.5 RR CW L B + Stroke CZ -0.1 -0.3 CL + Stroke Bore size (mm) Standard stroke CW CX CZ N RR A + Stroke 32 20 18 36 M6 x 1.0 10 Rod end male thread 40 22 18 36 M6 x 1.0 10 10, 15, 20, 25 50, 75, 100 50 28 22 44 M8 x 1.25 14 63 30 22 44 M10 x 1.5 14 80 38 28 56 M12 x 1.75 18 25, 50, 75, 100 100 45 32 64 M12 x 1.75 22 Rod end nut L1
Standard condition : Air in a temperature state of 20C, absolute pressure 0.1 MPa (= 100 kPa = 1 bar), relative humidity 65%. It is stipulated by adding the (ANR) after the unit depicting air volume.
23 27 28 46 (kg) AM Body panel: White 1 Base: Gray 2 Coating color Refrigerated air dryer AMD EC Directive (with CE marking) Compliant standards Auto drain Note 1) Air flow capacity under the standard condition (ANR) [atmospheric pressure at 20C, relative humidity at 65%] Note 2) Air flow capacity converted by the compressor intake condition [atmospheric pressure at 32C, relative humidity
H/DL L/LL Soft polyurethane tubing 2 cores X169 (Roll) 3 cores X170 (Roll) 4 cores X171 (Roll) 5 cores X172 (Roll) Fluid Air Max. operating pressure MPa KC Number of cores KK Inner sleeve 20C 0.6 40C 0.6 60C 0.4 Applicable fittings One-touch fitting Note 2), Insert fitting, Miniature fitting (Hose nipple type) Min. bending radius Note 1) (mm) 8 15 15 22 29 Operating temperature 20 to +60C