Bore Size: 15mm, Stroke: 300mm, Piping Port Position: Port Location a, b Operating Direction Right Left, Auto Switch: Y59AL--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, 3M, Number: -
Bore Size: 15mm, Stroke: 400mm, Piping Port Position: Port Location a, b Operating Direction Right Left, Auto Switch: Y59AL--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, 3M, Number: -
Bore Size: 32mm, Stroke: 150mm, Piping Port Position: Port Location a, b Operating Direction Right Left, Auto Switch: Y59AL--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, 3M, Number: -
Bore Size: 15mm, Stroke: 200mm, Piping Port Position: Port Location a, b Operating Direction Right Left, Auto Switch: Y59AL--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, 3M, Number: -
This is a legacy product, and replaced byMGQL20TN-20-Y59AL
Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz External pilot Nil VT N.C.
Standard external (B) 17 25 35 36 46 60 70 86 100 Dimensions except mentioned above are the same as standard type.
30 45 60 Horizontal (2000 [mm/s2]) 30 60 70 40 60 80 Work load [kg] Note 2) For LECPA (3000 [mm/s2]) 12 30 30 20 40 40 (2000 [mm/s2]) 18 50 50 30 60 60 Actuator specifications Vertical Note 15) (3000 [mm/s2]) 7 15 29 10 21 42 Pushing force [N] Note 3) Note 4) Note 5) 63 to 122 126 to 238 232 to 452 80 to 189 156 to 370 296 to 707 Speed [mm/s] Note 5) 18 to 400 9 to 200 5 to 100 24 to 400
1200 60 1200 60 1200 60 1200 12 65 1400 65 1400 70 1400 70 1400 13 70 1600 70 1600 80 1600 80 1600 14 75 1800 75 1800 90 1800 90 1800 15 80 2000 80 2000 100 2000 100 2000 LEHZ32 LEHZ40 2] 2] [mm/s] [mm/s [mm/s] [mm/s 0 5 100 5 100 1 10 150 10 150 2 15 200 15 200 3 20 300 20 300 4 25 400 25 400 5 30 500 30 500 6 35 600 35 600 7 40 700 40 700 8 50 800 50 800 9 60 900 60 900 10 70 1000 70 1000
The load factor for each direction can be obtained as follows. x = 0/400 = 0 y = 50/250 = 0.2 z = 200/1500 = 0.13 5. x + y + z = 0.33 1 2000 1000 2000 800 1500 1500 Lz 600 L1 [mm] L3 [mm] L2 [mm] 1000 1000 400 Ly 500 500 200 Lx 0 0 0 0 10 20 30 40 50 60 0 10 20 30 40 50 60 0 10 20 30 40 50 60 Work load [kg] Work load [kg] Work load [kg] 44 Model Selection LEF Series Step Motor (Servo/24
) 1 VQZ 04 06 10 12 14 20 VZ Option (32A) 1 4 1 (40A) 1 2 1 Coil rated voltage VS 1 2 3 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz JIS Symbol Internal pilot
N.O. 1 2 3 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz 24 VDC 12 VDC 240 VAC, 50/60 Hz Note) N.O. valve operates properly only when appropriate pressure is applied to the pilot.
Nil E Yes Without light, with surge voltage suppressor Seal Metal seal Rubber seal 0 1 Coil voltage Function 1 2 3 Stations 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC D side U side Standard type (1 W) Low wattage type (0.5 W) External pilot Nil Y R (1) (2) Applicable to DC sepecifications.
Applicable model D7 L26 L28 AS-10A AS1002FS 9.2 4 18.7 AS-20A AS2002FS 9.4 8.8 20.4 AS-25A AS2052FS 11.4 6.3 27 AS-30A AS3002FS 11.8 5.9 32.1 Part no. Applicable model D7 L27 L28 AS-10A1 AS1002FS 9.2 4.5 18.7 AS-20A1 AS2002FS 9.4 9.3 20.4 AS-25A1 AS2052FS 11.4 7.1 27 AS-30A1 AS3002FS 11.8 6.4 32.1 2 x D7 2 x D7 L26 L27 L28 L28 The AS4002FS can be mounted without the adapter.
Example; it takes approximately 8.8 seconds when the ullimate vacuum pressure is -89.kPa (25.9 in-Hg) -60 (23.21 6 -zo tzo et ,9 -oo 1rz r; 9.
Example; it takes approximately 8.8 seconds when the ullimate vacuum pressure is -89.kPa (25.9 in-Hg). -60 (23.21 6 -zo tzo et ,9 -oo 1rz r; 9.
Hz Symbol Option Without sub-plate VP454 2 200 VAC, 50/60 Hz 00 3 110 VAC, 50/60 Hz VP474 4 220 VAC, 50/60 Hz (10A) 3 8 (15A) 1 2 03 04 5 24 VDC VP450 6 12 VDC 06 (20A) 3 4 10 (25A) 1 7 240 VAC, 50/60 Hz 9 Other 12 (32A) 1 4 1 14 (40A) 1 2 1 VP470 Option Note) There is no 3 position type for Series VP470.
81.5 83.5 2-M6 X 1 X Depth 9 1 2 3 4 60 143.5 62.5 156.5 36.5 16.5 20 Center 116.5 70 25 VEX5700 VEX5701 1 4 1 4 160.5 150.5 62.5 90 60 30 15 7 173.5 37.5 100 13 88.5 86.5 18 4-M6 X 1 X Depth 6 136.5 60 17 82 c Bracket mounting dimensions g Grommet h Grommet terminal i Conduit terminal j DIN connector a Model b d e f VEX5500 VEX5501 19 130 110 9 12 2.3 187 187.5 205.5 205 32 VEX5700 VEX5701
VEX5511-062EZ-BG Body size 5, Select, External pilot solenoid Port size 3/4 200 VAC, Grommet terminal, with light/surge voltage suppressor OptionBracket, with pressure gauge 5 3 4 200 VAC 50/60 Hz 1 1 1 110 VAC 50/60 Hz 4 7 220 VAC 50/60 Hz 24 VDC 12 VDC 11 4 11 4 5 6 11 2 9 2 2 7 240 VAC 50/60 Hz Other 9 Option Thread type Nil F N T Rc G(1) NPT NPTF Note 1) Not conforming to ISO1179-1.
Plug-in Common Dimensions Made to Order Manifold Exploded View