SMC Corporation of America
Elite Part Number Search
Search Results "25A-MXP10-20C"

65 or less Gray 23 Red 1000 Withstand voltage VAC, 1 minute Black 24 White Insulation resistance Mkm, 20C 5 or less White 25 None Note) The minimum bending radius of each cable is 20 mm.

Property 65 or less Cable length (L) Conductor resistance /km, 20C AXT100-MC26-015 AXT100-MC26-030 AXT100-MC26-050 1.5 m 3 m 5 m Cable 25-core x 24AWG 10 Voltage limit V, 1 minute, AC 1000 Cannot be used for transfer wiring.

Furthermore, abnormal temperature rises caused by adiabatic compression may result in the burst of the tube. 3.The value of the minimum bending radius is measured at the temperature of 20C as shown in the figure on the right. Bend the tube into U-form at a temperature of 20C. Fix one end and close loop gradually. Measure 2R when the tube breaks or is crushed. Fixed end 1232

. *5 Inlet pressure: 0.7 MPa Flow at 20C, atmospheric pressure, and 65% of the relative humidity 7 Compressed Air Preparation Filter AFF/AM/AMD Series Line Filter AFF Series Flow Rate Characteristics (Representative values) AFF/AM/AMD AMK Modular Connection Example Compressed air over the max. flow capacity line in the table below may not meet the specifications of the product.

Approx.1200W(water), 800W(Fluorinert FC-77) Cooling capacity Conditions: set temp. 25C, ambient temp. 25C, radiating water temp. 20C, radiating water flow rate 10 L/min Approx.2200W(water), 1500W(Fluorinert FC-77) Heating capacity Conditions: set temp. 25C, ambient temp. 25C, radiating water temp. 20C, radiating water flow rate 10 L/min Recirculating fluid : Water, Fluorine solvent(GALDEN

MHK2-12S 120 12 9 4 9 13 76 Normally open Normally closed MHK2-16S 16 23 6 14.6 20.6 114 DL1 MHK2-20S 20 34 10 16 26 237 L2 MHK2-25S 25 58 14 19 33 443 20MHK2-12C 12 12 4 9 13 76 MHK2-16C 16 25 6 14.6 20.6 115 MHK2-20C 20 44 10 16 26 237 MHK2-25C 25 73 14 19 33 443 Series MHKL2/Long Stroke Type Note) Width at opening (mm) L2 Width at closing (mm) L1 Effective gripping force per finger (N)

Material Case Note 1 Stainless steel 316 Electrolytic polishing (Interior/Exterior) V-clamp 2 Stainless steel 304 Holder 1 3 Polyester Holder 2 4 Filter medium 5 Element PTFE Seal 6 FKM V-seal 7 300 SFA100/200/300 Series Clean Gas Filter: Cartridge Type/Disc Type Flow Rate Characteristics Fluid: Compressed air Inlet temperature: 20C Dimensions SFA100/101, SFA200/201, SFA300/301 SFA10 Inlet

) Max. operating pressure (at 20C) 0.8MPa 1.5MPa Refer to series TU burst pressure characteristics curve.

size 3.2, 4, 6 3.2, 4 6, 8, 10 8, 10 4 6 6 8 10 12 10, 12 Tubing O.D. 1/8", 5/32" 1/8" 3/16", 1/4" 1/4", 5/16" 3/8" 1/4" Inch size 5/32" 3/16" 5/16" 3/8" 1/2" 5/32" 5/16" 3/8" 3/16", 1/4" Controlled flow (Free flow) Flow rate (l/min (ANR)) 100 180 230 260 390 660 790 1580 1710 460 920 Effective area (mm 2) 1.5 2.7 3.5 4 6 7 10 12 14 24 26 Note) Flow rate values are measured at 0.5 MPa and 20C

AK ASS ASR ASF Flow Rate and Effective Area JIS Symbol ASD230FM ASD330FM ASD430FM Model 6, 8 8, 10 6 Metric size 4, 6 Tubing O.D. 1/8", 5/32" 3/16", 1/4" 1/4", 5/16" 3/8" 3/16", 1/4" Inch size Flow rate (l/min(ANR)) Controlled flow (Free flow) 7 12 38 0.1 0.6 0.2 Effective area (mm 2) Note) Flow rate values are measured at 0.5 MPa and 20C.

8, 10 3.2, 4 4 6 6 8 10, 12 10 12 Tubing O.D. 1/8", 5/32" 3/16", 1/4" 3/16", 1/4" 5/16" 1/4", 5/16" 3/8" 1/8" 5/32" 1/4" Inch size 5/32" 3/16" 5/16" 3/8" 3/8" 1/2" Flow rate (l/min (ANR)) 100 230 180 260 390 460 660 790 920 1580 1710 Controlled flow (Free flow) 1.5 3.5 2.7 4 6 7 10 12 14 24 26 Effective area (mm2) Note) Flow rate values are at a pressure of 0.5 MPa and a temperature of 20C

MHK2-12S 120 12 9 4 9 13 76 Normally open Normally closed MHK2-16S 16 23 6 14.6 20.6 114 DL1 MHK2-20S 20 34 10 16 26 237 L2 MHK2-25S 25 58 14 19 33 443 20MHK2-12C 12 12 4 9 13 76 MHK2-16C 16 25 6 14.6 20.6 115 MHK2-20C 20 44 10 16 26 237 MHK2-25C 25 73 14 19 33 443 Series MHKL2/Long Stroke Type Note) Width at opening (mm) L2 Width at closing (mm) L1 Effective gripping force per finger (N)

Speed controller Cylinder Solenoid valve Tube Silencer Maximum return speed mm/s 100 200 300 6 ASD230FG CJ2 VJ500 TU0604 1m AN11001 10 16 Cylinder size 20 ASD330FG CM2 VZ500 TU0604 1m AN11001 25 Cylinder size 32 Values for pressure of 0.5MPa and temperature of 20C.

Note2) The value at temperature of 20C and O.D. variable rate 10% max.

53 External hold: 79 Internal hold: 90 MHKL2-16D 16 14 14.6 28.6 164 Double acting MRHQ MHKL2-20D 20 18 16 34 312 Auto switch MHKL2-25D 25 22 19 41 562 MHKL2-12S 90 105 20 9 11 12 9 Normally open Normally closed MHKL2-16S 165 28.6 14.6 14 16 17 MHKL2-20S 314 34 16 18 20 32 MHKL2-25S 565 41 19 22 25 53 L1 Single acting MHKL2-12C 105 20 9 11 12 11 L2 MHKL2-16C 166 28.6 14.6 14 16 22 MHKL2-20C

16" 3/8" 3/16", 1/4" l/min (ANR) (CFM) 7 (0.25) 12 (0.42) 38 (1.33) Flow rate Controlled flow 0.1 (0.006) 0.6 (0.03) 0.2 (0.01) Effective area mm (cv) Free flow l/min (ANR) (CFM) Flow rate 175 (6.1) 350 (12.3) 75 (2.6) 295 (10.3) 5.3 (5.3) 2.7 (0.15) 1.1 (0.06) Effective area mm (cv) 4.5 (0.25) Note 1) Flow rates are the values measured with pressure at 0.5MPa (72psi) and temperature at 20C

46) I.D.holding :12.6 (56) MHK2-20D 20 10 16 26 8.3 O.D. holding:18.0 (80) I.D. holding :19.3 (86) MHK2-25D 25 14 19 33 15.5 MHK2-12S 120 12 2.0 (9) 4 9 13 2.7 Normally open Normally closed MHK2-16S 16 5.2 (23) 6 14.6 20.6 4.0 MHK2-20S 20 7.6 (34) 10 16 26 8.4 L1 MHK2-25S 25 13.0 (58) 14 19 33 15.6 Single acting L2 MHK2-12C 12 2.7 (12) 4 9 13 2.7 MHK2-16C 16 5.6 (25) 6 14.6 20.6 4.1 MHK2-20C

3/16" 1/4" 3/16", 1/4" 5/16" Tube O.D. 1/4", 5/16" 3/8" 1/8", 5/32" 5/32" 3/16" Inch size 12 7 38 Flow rate l/min (ANR) Controlled flow 0.2 0.1 0.6 Effective area mm Flow direction symbols on body 230 180 100 460 260 390 Flow rate l/min (ANR) Meter-out type Meter-in type Free flow 3.5 2.7 1.5 7 4 6 Effective area mm Note) The flow rate value is at a pressure of 0.5MPa and temperature of 20C

Inch sizes 1/4", 5/16" 3/16" 5/32" 3/16", 1/4" 1/8", 5/32", 3/16", 1/4" l/min (ANR) {Nl/min} Flow rate 12 38 7 Controlled flow Effective area mm 0.2 0.6 0.1 l/min (ANR) {Nl/min} Flow rate 460 100 290 130 230 Free flow Effective area mm 7 1.5 4.5 2 3.5 Note) Flow rates are values measured with pressure at 0.5MPa and temperature at 20C.

Note) l/min (ANR) is for reference conditions of 20C, 1 ATM and 65% relative humidity. Features 3 Model Selection Data A Correction factor for temperature/Series IDU Inlet air temp.