10(S)A 10 15.9 17.4 23 41.2 26.1 62.5 15.6 46 (46) AS33l1FG-02-12(S)A 12 18.5 42.5 28.3 64.7 17 48 (48) AS33l1FG-03-06(S)A 6 11.2 12.9 16.6 20.2 36 21.4 57.8 AK 1/4 19 50 48.4 44.5 42.9 VCHC 13.3 32 (33) AS33l1FG-03-08(S)A 8 13.2 37.1 23.5 52.2 14.2 33 (34) AS33l1FG-03-10(S)A 10 15.9 17.4 23 41.2 26.1 54.8 15.6 37 (38) AS33l1FG-03-12(S)A 12 18.5 42.5 28.3 57 17 38 (39) AS43l1FG-04-10(S)A
L1 L2 L3 L4 M d Effective orifice (mm 2) Weight (g) A O.D.
D Plug-in Reducer: KPQR, KPGR Applicable tubing D Effective area mm Note 1) D Model L TPH TPS Applicable fitting size d Applicable tubing O.D. mm Weight g M A 39.4 20.1 3 KPQR04-06 KPGR04-06 6 4 10.4 18 4 4 M A L 41.9 20.2 4 KPQR04-08 KPGR04-08 8 42.5 20.8 4 KPQR06-08 KPGR06-08 6 12.8 19.5 10 10 45 21.2 5 KPQR06-10 KPGR06-10 Applicable fitting size d 10 47 23.2 5 KPQR08-10 KPGR08-10 8 15.2
D Plug-in Reducer: KPQR, KPGR Applicable tubing D Effective area mm Note 1) D Model L TPH TPS Applicable fitting size d Applicable tubing O.D. mm Weight g M A 39.4 20.1 3 KPQR04-06 KPGR04-06 6 4 10.4 18 4 4 M A L 41.9 20.2 4 KPQR04-08 KPGR04-08 8 42.5 20.8 4 KPQR06-08 KPGR06-08 6 12.8 19.5 10 10 45 21.2 5 KPQR06-10 KPGR06-10 Applicable fitting size d 10 47 23.2 5 KPQR08-10 KPGR08-10 8 15.2
D Plug-in Reducer: KPQR, KPGR Applicable tubing D Effective area mm Note 1) D Model L TPH TPS Applicable fitting size d Applicable tubing O.D. mm Weight g M A KPGR04-06 KPQR04-06 3 39.4 20.1 6 4 M A L 10.4 18 4 4 KPGR04-08 KPQR04-08 41.9 20.2 4 8 KPQR06-08 KPGR06-08 20.8 4 42.5 6 12.8 19.5 10 10 KPQR06-10 KPGR06-10 5 21.2 45 Applicable fitting size d 10 KPGR08-10 KPQR08-10 5 47 23.2 8 15.2
Plug: KPP Applicable fitting size d Weight g D Model L A L A 4 0.4 6 32 13.8 KPP-04 D d 6 15.7 0.7 8 35 KPP-06 8 10 39 17.3 1.1 KPP-08 Applicable fitting size d 10 12 19.2 1.7 43 KPP-10 12 2.5 14 45.5 20.7 KPP-12 The plug is commom for series KPQ, KPG and KP. 9
L 310.5 23 298 22 335.5 25 323 24 360.5 27 348 26 385.5 29 373 28 410.5 31 398 30 435.5 33 423 32 460.5 35 448 34 485.5 37 473 36 39 498 38 40 510.5 VP4 Fitting blank plug KQP-23-X19 KQP-04-X19 KQP-06-X19 KQP-08-X19 KQP-10-X19 VQ L A Dimensions VQ4 Applicable fitting d Part No.
L4 Note) Weight (g) 3 5 5.5 6.5 8.5 9.5 19 22 36 38 42 44 76 82 Model D1 Applicable tube O.D. d AS1002F-02 AS1002F-23 AS1002F-04 AS1002F-06 AS2002F-04 AS2002F-06 AS2052F-06 AS2052F-08 AS3002F-06 AS3002F-08 AS3002F-10 AS3002F-12 AS4002F-10 AS4002F-12 D2 D3 D4 L1 L2 L3 L5 L6 L7 L8 M1 MIN. 18.4 21 21.7 22.7 25.4 26.5 28.2 29.5 33.6 34.4 36 37.1 44.1 45.1 6 8.4 9.3 11.6 9.3 11.6 12.8 15.2 13.2
How to Order 1F 06 T 200 AS Flow direction symbol on body Tamper proof type Body size Note) A special tool necessary for flow rate adjustment should be ordered separately.
ANSI symbol shows the valve as a single inlel 4.way, bul valve may be used, withoul modilica. tion, as a dual inlet 4.way, a 3.way, or a 2-way, by piping and/or plugging lhe appropriate ports.
Facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air vent on a wall at a low level.
Facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air vent on a wall at a low level.
Facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air vent on a wall at a low level.
Facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air vent on a wall at a low level.
SY SYJ VK Blank plug KQP-23-X19 KQP-04-X19 KQP-06-X19 KQP-08-X19 KQP-10-X19 VZ L Dimensions VT (mm) A One-touch fitting d Part No.
Using a regulator in the outlet side When mounting a regulator in the outlet side (A port side), use a residual pressure relief regulator (AR25K to 40K) or a check type regulator. With a standard regulator (AR10 to 60), the outlet side pressure may not be released when this valve is exhausted. 5.
1 1 1 1 2 (a) (a) (b) (c) (a) (b) (c) (b) (c) (a) (b) (c) (a) (b) (c) (b) (c) (a) (b) (c) (b) (c) (a) (b) (c) Note 1) The above (a), (b), (c) indicate heater mounting positions.
B-1 2 L A A-1 1 B (B-2) 6 1 1.5m B (A-2) 5 COM-A/COM B-3 3 3 3m COM-B/ A-3 4 5 5m (3) Shiel d Vcc (B-4) 12 GND (A-4) 13 A (B-5) 7 A (A-5) 6 S B (B-6) 9 B (A-6) 8 3 (14.2) (2 ) 2 1 (8) (1 ) B1 A1 (14) (18) (17.7) 6 5 (3 ) 2 1 B6 A6 15 16 (11) (30.7) 15.2 [820m] (1) (2) -L A B-1 2 A A-1 1 B (B-2) 6 8 8m* B (A-2) 5 COM-A/COM B-3 3 A 10m* COM-B/ A-3 4 B 15m* (3) Shield