Magnet: Built-in Magnet, Series: J2RKA, Bore Size: 16mm, Stroke: 175mm, Head Cover Port Location: Perpendicular to Axis, Rod End Bracket: Single Knuckle Joint, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: Band Mounting
Magnet: Built-in Magnet, Series: J2RKA, Bore Size: 16mm, Stroke: 150mm, Action: Single Acting, Spring Return, Head Cover Port Location: Axial, Rod End Bracket: Rod End Cap, Round Type, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 1 pc., Auto Switch Mounting Type: Band Mounting
Magnet: D (Built-in Magnet), Series: J2RKA, Bore Size: 16mm, Stroke: 150mm, Action: S (Single Acting, Spring Return), Head Cover Port Location: R (Axial), Rod End Bracket: U (Rod End Cap, Round Type), Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.), Auto Switch Mounting Type: B
(Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting)
Symbol Nil A B C D-M9N(M)(L)(Z) D-M9P(M)(L)(Z) D-M9B(M)(L)(Z) D-A90(L) D-A93(M)(L)(Z) M9N(M)(L)(Z) M9P(M)(L)(Z) M9B(M)(L)(Z) A90(L) A93(M)(L)(Z) M9// Solid state auto switch Reed auto switch (Not applicable to flange size 16) Without auto switch (with built-in magnet) Standard lead wire length is 0.5 m.
MY1CW16/20 MY1MW16/20 MX B A MTS Reed Switch Solid State Switch D-A90(V), D-A93(V), D-A96(V) (mm) D-M9N(V), D-M9P(V), D-M9B(V) D-F9NW(V), D-F9PW(V), D-F9BW(V) MY 16 20 Mounting position 16 20 Mounting position Mounting position 16 20 93 94 A A A 73 74 70 90 CY 107 106 B B B 87 86 90 110 6.5 7 8.5 6.5 Operating range Note) Operating range Note) Operating range Note) 11 7.5 MG Courtesy of Steven
D-M9P D-M9NV D-M9B D-M9N D-M9PV D-M9BV Auto switch part no.
A B Hs Hs Hs Hs Hs Hs Hs Hs Hs Hs D-M9lV D-M9lWV D-M9lAV D-A9lV D-M9lV D-M9lWV D-M9lAV D-A9lV 17 B A A B D-H7l D-H7lW D-H7BA D-H7NF D-C7l D-C80 D-F7l D-F7lW D-J79 D-J79W D-F7BA D-F79F D-A7lH D-A80H 17 A B A B D-F7lV D-F7lWV D-F7BAV D-A7l D-A80 D-A79W D-H7C 17 A B A B D-C73C D-C80C D-J79C D-A73C D-A80C 17 Auto Switch Made to Order B A B A 102 C85/C75 Series Auto Switch Proper Mounting
1-C 2-A 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 2-B 2-B 1-A 1-B 1-C 2-A 2-B 1-C 2-A 2-B 2-B 2-B 2-B 2-B 1-A 1-B 1-C 2-A 2-B 2-B 2-B 2-B 2-B 2-B Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 6 1/8, 1/4 500 1.5 0 1,000 2,000 3,000
Slide Bearing Felt Holder Ball bushing Spacer Aluminum alloy Replacement Parts: Seal Kit Bore size (mm) Contents Kit no. 20 25 32 40 50 MGP20-B-PS MGP25-B-PS MGP32-B-PS MGP40-B-PS MGP50-B-PS Set of nos. above @1, @2, @3, @4, #2, #3, $1, $2 Seal kit includes @1 to @4, #2, #3, $1, $2.
S E 20 180 S Z CRB2 u CDRB2 B W 20 180 S Z L M9B With auto switch q r e !
A B A B B A B A B A B B A B A B A 10 16 2 2 6 6 2.5 2.5 1.5 1.5 0.5 0.5 4.5 4.5 3 3 3.5 3.5 8.5 8.5 0.5 0.5 2.5 2.5 6.5 6.5 3 3 2 2 1 1 5 5 3.5 3.5 4 4 9 9 1 1 Note) Adjust the auto switch after confirming the operating conditions in the actual setting.
Inrush Current Flow Time (Reference) 200 V Current 100 V 0 5 15 10 20 25 30 Time [Second] 2 Mounting position of the heater Heater symbol XL-25-2 XL-40-2 XL-50-2 XL-63-2 XL-80-2 H4 (100C) (a) (a) (b), (c) (a), (b), (c) H5 (120C) (a) (b), (c) (b), (c) (a), (b), (c) (b), (c) (b) (a) (c) Heater (Option) 17 Aluminum High Vacuum Angle Valve: With Heat-resistant Auto Switch XLm Series Made to
A B A HS 056 HS B A B A 075, 106 HS B A B A 150, 200, 250 Note 1) Figures in the table below are references for auto switch mounting positions in the stroke end detection.
3.2 D-M9B (2-wire) OUT Black Most sensitive position 6 DC(-) Blue 22 D-M9B OUT(+) Brown OUT(-) Blue 18
CM3 Auto Switch Proper Mounting Position (Centralized piping type, With end lock) CG1 (mm) Auto switch model D-H7l D-H7C D-H7lW D-H7BA D-H7NF CG3 D-C7l D-C80 D-C73C D-C80C D-G39A D-K39A D-A3lA D-A44A D-M9l(V) D-M9lW(V) D-M9lA(V) D-A9l(V) D-G5NT D-B5l D-B64 D-B59W JMB MB A B A B A B A B A B A B A B A B Bore size MB1 20 10.5 (8) 9.5 (7) 6.5 (4) 5.5 (3) 0.5 () 0 () 6 (4) 5 (3) 2.5 (0.5) 1.5
Double clevis type Lock location Port (A) (A) (A) (A) (A) (A) (A) (B) (D) (B) (D) (B) (B) (D) (D) (B) (B) (B) (D) (D) (D) CLS (C) (C) (C) (C) (C) (C) (C) Cushion valve 1.
5 A-A t y @2 C B e @1 !0 C B r w C-C B-B !4 !2 Body Table !3 Component Parts No. Description Material Note No.
Next, B is entered to find A the inertial moment for the rotation of shaft (A) as 5 b a A = ( ) 2 B Number of teeth = b Kinetic Energy/Rotation Time Even in cases where the torque required for rotation of the load is small, damage to internal parts may result from the inertial force of the load.
Be careful not to exchange the power cable (brown) with the output cable (black). 10-20-37 38 Solid State Switch Direct Mounting Style D-Y59 /D-Y69 /D-Y7P(V) A B A B For details about certified products conforming to international standards, visit us at www.smcworld.com.