Determination of kinetic energy of load (E) E > Es E Es Bore size determination Tentative determination of L type W V 2 E = () 2 1000 Note 2) E > Es Determination of pressure (P) when making intermediate stop P > Ps P Ps Consider made-to-order products, depending on an operating condition. Tentative determination of L type (For intermediate stops, refer to page 1515.)

800 1000 1200 1400 1600 0 200 400 600 800 1000 1200 1400 1600 0 0 0 0 Installation distance [mm] 0 200 400 600 800 1000 1200 1400 1600 0 200 400 600 800 1000 1200 1400 1600 Installation distance [mm] 0 200 400 600 800 1000 1200 1400 1600 0 200 400 600 800 1000 1200 1400 1600 Installation distance [mm] Installation distance [mm] Installation distance [mm] Installation distance [mm] IZF10R

OUT IN OUT IN e q r r w w AR50, 60 AR30, 40 t q t q e e IN OUT IN OUT r w w r Parts list Material Color No.

Without lead wire Nil 6 10 15 20 25 30 300 600 1 2 3 Blue (2) For 100 VAC For 200 VAC Another VAC 1000 1500 2000 2500 3000 Socket Hook Red (2) Gray (2) 4 Red: +, Black: For DC Note) When ordering a valve in which the length of the wire is more than 600 mm, be sure to indicate the model number of valve without connector and connector assembly. Ex.)

F E E F B C Cross interface E: 4-Rc E A F: Without thread D Model Port size A B C D Applicable model Y14-M5 M5 23 16 14 25 AC10 Y24-01 1/8 40 40 22 40 AC20 Y24-02 1/4 Y34-01 1/8 49 43 28 48 AC25, AC30 Y34-02 1/4 Y44-02 1/4 60 48 36 54 AC40 Y44-03 3/8 Cautions in Mounting When mounting a cross interface directly on the IN side of the lubricator, be sure to use a series AKM check valve between

Unit psig/bar MPa Code r e No code MPA Sample Order Number Port qIN wOUT eGauge port (Inlet) rGauge port (Outlet) w q AZ1402TS e q FV4 FV4 FV4 FV4 w FV4 FV4 FV4 FV4 r 3) Pressure gauge unit MPa or psig/bar selectable.

900 1000 700 600 500 400 300 200 100 0 E 800 900 1000 700 600 500 400 300 200 100 0 F 800 900 1000 700 600 500 400 300 200 100 0 G When the cylinder is extended, the speed controller is metered-out, is connected with the cylinder directly, and its needle is fully open.

Magnet: D (Built-in), Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 40mm, Thread: TN (NPT), Stroke: 125mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: M9BAV--Solid State, Water Resist., 2 Wire, Vertical, Lead Wire or Prewied Connector: L (3m)

Magnet: D (Built-in), Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 40mm, Thread: TN (NPT), Stroke: 150mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewied Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)

Magnet: D (Built-in), Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 40mm, Thread: TN (NPT), Stroke: 250mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewied Connector: L (3m), Number: 3 pcs.

Magnet: D (Built-in), Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 40mm, Thread: TN (NPT), Stroke: 500mm, Option: N [w/o Rod Boot, w/o Cushion (Not Valid for Air-hydro), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: M9PV--Solid State, Gen. Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewied Connector: MAPC (1.0m Cord Length, M8-3 Pin Connector)

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.08 to 1.0, Specification: Built-in magnet

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 40mm, Thread: NPT, Stroke: 125mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: M9BAV--Solid State, Water Resist., 2 Wire, Vertical, Lead Wire or Prewied Connector: 3m, Number: -

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 40mm, Thread: NPT, Stroke: 150mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewied Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 40mm, Thread: NPT, Stroke: 250mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewied Connector: 3m, Number: 3 pcs.

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 40mm, Thread: NPT, Stroke: 100mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewied Connector: 3m, Number: -

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 40mm, Thread: NPT, Stroke: 200mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewied Connector: 3m, Number: -

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 40mm, Thread: NPT, Stroke: 200mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: F5PW--Solid State, 2-color Indication, 3 Wire PNP, Lead Wire or Prewied Connector: 3m, Number: -

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 40mm, Thread: NPT, Stroke: 250mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewied Connector: 3m, Number: -