SMC Corporation of America
Elite Part Number Search
Search Results "CDLA2L80-700-D"

Magnet: D (Built-in), Mounting: L (Axial Foot), Style: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 300mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: D (Spring/Air Pressure Lock), Auto Switch: M9PWV--Solid State, 2-color Indication, 3 Wire PNP, Vertical, Lead Wire or Prewied Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector)

Magnet: D (Built-in), Mounting: L (Axial Foot), Style: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 125mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: D (Spring/Air Pressure Lock), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewied Connector: L (3m)

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification

Magnet: Built-in, Mounting: Axial Foot, Style: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 300mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: M9BV--Solid State, Gen. Purpose, 2 Wire, Vertical, Lead Wire or Prewied Connector: 0.5m Cord Length, M12-4 Pin Connector, Number: -

Magnet: Built-in, Mounting: Axial Foot, Style: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 300mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewied Connector: 0.5m Cord Length, M12-4 Pin Connector, Number: -

Magnet: Built-in, Mounting: Axial Foot, Style: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 300mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: M9PWV--Solid State, 2-color Indication, 3 Wire PNP, Vertical, Lead Wire or Prewied Connector: 0.5m Cord Length, M12-4 Pin Connector, Number: -

Magnet: Built-in, Mounting: Axial Foot, Style: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 125mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewied Connector: 3m, Number: -

Magnet: Built-in, Mounting: Axial Foot, Style: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 450mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: J59--Solid State, Gen. Purpose, 2 Wire, Lead Wire or Prewied Connector: 3m, Number: -

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification

Auto Switch Proper Mounting Position (mm) A B C D Auto switch model D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV D-A9 D-A9V D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV 36.5 41.5 56.5 67 67 83.5 92.5 D-A9 D-A9V D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV 17.5 17.5 17.5 18 18 19.5 18.5 D-A9 D-A9V D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV 24.5 29.5 44.5 55 55 71.5 80.5 D-A9 D-A9V K dimension (Switch rail height) Bore

It is already built into the rectifier circuit. 2 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] 3 4 220 VAC 50/60 Hz [230 VAC 50/60 Hz] Electrical entry D With connector DIN terminal (Type D) DC specifications of type D and DO are only available with 12 and 24 VDC. Power saving circuit is not available for D or DO types.

3 Port Solenoid Valve Rubber Seal Series SYJ300/500/700 SY SYJ Low power consumption: 0.5W (Without light) (Current draw: 21mA at 24V DC) VK VZ Completely interchangeable with the previous series VJ300/500/700 and VZ300/500. VT Pilot exhaust VT VP Mounts on the same subplates and manifolds as the VJ300/500/700 and the VZ300/500.

H H H H G E G X E X Note ) E X RG RT RS B 600 740 C R310 R445 D 296 302 E 620 890 F 93 129 G 60 87 B 680 790 C R390 R495 D 296 302 E 780 990 F 93 129 G 60 87 B 640 740 C R350 R440 D 296 307 E 634 800 F 93 129 H 10 15 A 700 1000 A 700 880 A 700 880 15 32 15 32 15 32 I 6 7 X 740 1064 Y Note 2) I 6 7 X 660 816 Y Note 2) X 700 880 Y Note 2) H 10 15 H 10 15 I 6 7 15 32 15 32 15 32 558 to 573

Data (A) Volume of Cylinder/Capacity of Converter 160 140 180 125 300 250 800 700 600 200 Selection Step 100 10,000 8,000 6,000 5,000 4,000 500 400 Step (1) Select the bore size of air-hydro cylinder 80 300 First of all, select a bore size from data (D) .

64 (102) 3H9 (+0.025 0 ) depth 3 4 x M5 x 0.8 thread depth 8.5 38 50 3.5 3H9 (+0.025 0 ) depth 3 A (Table traveling distance) L 51 (52) 10 10 58 38 48 38.5 (48) 26 24 n x 4.5 Vacuum port Rc1/8 48 120 F D x 120 (= E) B Dimensions [mm] Dimensions [mm] Model L A B n D E F 11-LEFG25-S-50 180 57 160 4 20 11-LEFG25-S-100 230 107 210 Model L A B n D E F 11-LEFG25-S-450 580 457 560 10 4 480 35

D D D D D D 3 2 1 Stations D side How to Order Solenoid Valves SV 1 1 0 0 F 5 Note) Available with manifold block for station additions. Refer to pages 77 and 81.

side D D D D D D SS5V1-16S3AD-06B-C61 set (manifold part no.)