SMC Corporation of America
Elite Part Number Search
Search Results "CDLSF160-200-D"

Magnet: Built-in, Mounting: Front Flange, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 160mm, Thread: Rc, Stroke: 700mm, Option: -, Cylinder Switch Type: -, Lead Wire or Pre-wired Connector: -, Number: -, Lock Unit Built-in Magnet: -, Lock Unit Switch Type: -

Magnet: Built-in, Mounting: Front Flange, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 160mm, Thread: Rc, Stroke: 1300mm, Option: -, Cylinder Switch Type: -, Lead Wire or Pre-wired Connector: -, Number: -, Lock Unit Built-in Magnet: -, Lock Unit Switch Type: -

Magnet: Built-in, Mounting: Front Flange, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 160mm, Thread: Rc, Stroke: 900mm, Option: -, Cylinder Switch Type: -, Lead Wire or Pre-wired Connector: -, Number: -, Lock Unit Built-in Magnet: -, Lock Unit Switch Type: -

Magnet: Built-in, Mounting: Front Flange, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 160mm, Thread: Rc, Stroke: 1600mm, Option: -, Cylinder Switch Type: -, Lead Wire or Pre-wired Connector: -, Number: -, Lock Unit Built-in Magnet: -, Lock Unit Switch Type: -

Magnet: Built-in, Mounting: Front Flange, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 160mm, Thread: Rc, Stroke: 1200mm, Option: -, Cylinder Switch Type: -, Lead Wire or Pre-wired Connector: -, Number: -, Lock Unit Built-in Magnet: -, Lock Unit Switch Type: -

Magnet: Built-in, Mounting: Front Flange, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 160mm, Thread: Rc, Stroke: 150mm, Option: Rear Cushion, Cylinder Switch Type: -, Lead Wire or Pre-wired Connector: -, Number: -, Lock Unit Built-in Magnet: -, Lock Unit Switch Type: -

Magnet: Built-in, Mounting: Front Flange, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 160mm, Thread: Rc, Stroke: 150mm, Option: Rear Cushion & Nylon Tarpaulin Rod Boot, Cylinder Switch Type: -, Lead Wire or Pre-wired Connector: -, Number: -, Lock Unit Built-in Magnet: -, Lock Unit Switch Type: -

Magnet: Built-in, Mounting: Front Flange, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 160mm, Thread: Rc, Stroke: 150mm, Option: Heat Resistant Tarpaulin Rod Boot & Cushion at Both Ends, Cylinder Switch Type: -, Lead Wire or Pre-wired Connector: -, Number: -, Lock Unit Built-in Magnet: -, Lock Unit Switch Type: -

It is already built-in to the rectifier circuit. 2 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] 3 Electrical entry 4 220 VAC 50/60 Hz [230 VAC 50/60 Hz] D With connector DIN terminal DO Without connector DC specifications of type D and DO is only available with 12 and 24 VDC. Power saving circuit is not available in the case of D or DO type.

Example) S2S2: Standard cable (2 m) + Driver (LECSS2) S2 : Standard cable (2 m) Nil : Without cable and driver Stroke (mm) Model 200 300 400 500 700 600 800 900 1000 1200 1500 2000 3000 LEJB40 LEJB63 D ) D D D ) ) D D D D ) ) D D ) ) D ) D D D D D 3: Strokes other than those shown above are produced as special order (1 mm increments). For auto switches, refer to pages 19, 20.

(kg) Applicable dryer Port size NPT A B C D E D E Part no.

Switch Mounting Height CA2 D-Y69 D-Y7PV D-Y7WV D-A3, D-G39 D-K39 D-A44 D-Z7, D-Y59 D-Z80, D-Y7P D-Y7W D-F5, D-F5W, D-F5NTL D-J5, D-J59W D-F59F, D-F5BAL D-A5 D-A6 D-A59W Bore size (mm) D-Y7BAL CS1 Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht 125 160 200 250 68.5 84.5 100.5 67.5 84.5 100.5 66.5 86 104 128 116 134.5 154 72 89.5 103 65 83 100.5 65 83 100.5 65 83 100.5 126 144.5 164 71.5 90

D-H7C D-B5, D-B6, D-B59W Auto switch Hs Hs Auto switch Single Acting, Spring Return Single Acting, Spring Extend Bore size (mm) A B All stroke A Bore size (mm) B Auto switch model Auto switch model Hs 150 200 Hs All stroke 25 75 25 75 50 100 50 100 125 125 150 200 20 20 30 24.5(27) 24.5(27) 55 80 45.5 70.5 55 80 45.5 70.5 105 95.5 20.5 D-C7 D-C8 D-C73C D-C80C D-C7 D-C8 D-C73C D-C80C 25 25

Top entry Side entry U S 2-4-12 Body Ported Series VQ1000 Plug-in Unit: Flip Type (Conforming to MIL-C-24308) Applicable connector: D-sub connector (25P) (Latching 200/220 VAC) P = 11 Indicator light Manual override 2-M4 mounting hole (Mounting hole dimension) VQC SQ VQ0 VQ4 VQ5 (5.2) VQZ 6 VQD D side U side Stations The broken lines indicate the DIN rail mounting style [-D] and the top entry

Switch Internal Circuit D-Y7GL Motor model Compatible driver model Power supply voltage (VAC) Motor output (W) + Brown lead wire 100/115 200/230 100/115 200/230 100/115 200/230 MSD5A1P1E MSD5A3P1E MR-C10A1 MR-C10A SGDE-A5BP SGDE-A5AP Main circuit of switch Matsushita Electric Industrial Co., Ltd.

10 248 237.5 216 16 Stations L1 L2 L3 L4 VV4Z1-25Station U-00C L plug connector (L) M plug connector (M) DIN terminal (D) (Pitch) D side U side (Station n)(Station 1) Applicable cable O.D. 3.5 to 7 (mm) 2 110.5 100 88 11.5 3 135.5 125 104 16 4 148 137.5 120 14 5 160.5 150 136 12.5 6 185.5 175 152 17 7 198 187.5 168 15 8 210.5 200 184 13.5 9 223 212.5 200 11.5 10 248 237.5 216 16 Stations

97.5 96 97.5 144 154 10 8 15 13 3.5 1.5 5.5 200 200 10 107.0 108.0 107.5 108.0 154 164 12.5 10.5 17.5 15.5 6 4 8 D-Y7/Z80 D-Y59/Y69/Y7P/Y7PV D-Y7W/Y7WV D-Y7BAL Operating Range Auto switch model Bore size (mm) 125 140 160 180 200 D-Z7/Z80 14.5 14 13 14 14.5 Hs D-A3/A44 D-A5/A6 A 10 10 10 10 10 D-A59W Ht 17 17 17 17 17 D-Y59/Y69 D-Y7P/Y7PV D-Y7W/Y7WV 8 7.5 7 12 13 D-Y7BAL