SMC Corporation of America
Elite Part Number Search
Search Results "CDRQ2BS40-90C-A93L"

Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for high temperature fluids , Integrated display type , Temperature range: 0 to 90C , Flow rate range: 0.5-4(l/min) ~ 5-40(l/min) , PNP/NPN open collector 2 outputs , Port sizes: 3/8, 1/2, 3/4, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, EB, IFW/PFW 3/8INCH NPT VERSION, 1.79897

Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for high temperature fluids , Integrated display type , Temperature range: 0 to 90C , Flow rate range: 0.5-4(l/min) ~ 5-40(l/min) , PNP/NPN open collector 2 outputs , Port sizes: 3/8, 1/2, 3/4, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, FB, IFW/PFW 1/2INCH NPT VERSION, 1.94006

Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for high temperature fluids , Integrated display type , Temperature range: 0 to 90C , Flow rate range: 0.5-4(l/min) ~ 5-40(l/min) , PNP/NPN open collector 2 outputs , Port sizes: 3/8, 1/2, 3/4, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, FB, IFW/PFW 1/2INCH NPT VERSION, 2.13114

Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for high temperature fluids , Integrated display type , Temperature range: 0 to 90C , Flow rate range: 0.5-4(l/min) ~ 5-40(l/min) , PNP/NPN open collector 2 outputs , Port sizes: 3/8, 1/2, 3/4, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, FB, IFW/PFW 1/2INCH NPT VERSION, 1.98416

Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for high temperature fluids , Integrated display type , Temperature range: 0 to 90C , Flow rate range: 0.5-4(l/min) ~ 5-40(l/min) , PNP/NPN open collector 2 outputs , Port sizes: 3/8, 1/2, 3/4, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, FA, IFW/PFW 1/2INCH PT VERSION, 1.98438

Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for high temperature fluids , Integrated display type , Temperature range: 0 to 90C , Flow rate range: 0.5-4(l/min) ~ 5-40(l/min) , PNP/NPN open collector 2 outputs , Port sizes: 3/8, 1/2, 3/4, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, FA, IFW/PFW 1/2INCH PT VERSION, 1.70011

Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for high temperature fluids , Integrated display type , Temperature range: 0 to 90C , Flow rate range: 0.5-4(l/min) ~ 5-40(l/min) , PNP/NPN open collector 2 outputs , Port sizes: 3/8, 1/2, 3/4, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, FA, IFW/PFW 1/2INCH PT VERSION, 2.20462

Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for high temperature fluids , Integrated display type , Temperature range: 0 to 90C , Flow rate range: 0.5-4(l/min) ~ 5-40(l/min) , PNP/NPN open collector 2 outputs , Port sizes: 3/8, 1/2, 3/4, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, GA, IFW/PFW 3/4INCH PT VERSION, 1.75767

Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for high temperature fluids , Integrated display type , Temperature range: 0 to 90C , Flow rate range: 0.5-4(l/min) ~ 5-40(l/min) , PNP/NPN open collector 2 outputs , Port sizes: 3/8, 1/2, 3/4, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, GA, IFW/PFW 3/4INCH PT VERSION, 1.76396

Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for high temperature fluids , Integrated display type , Temperature range: 0 to 90C , Flow rate range: 0.5-4(l/min) ~ 5-40(l/min) , PNP/NPN open collector 2 outputs , Port sizes: 3/8, 1/2, 3/4, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, GA, IFW/PFW 3/4INCH PT VERSION, 1.85818

Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for high temperature fluids , Integrated display type , Temperature range: 0 to 90C , Flow rate range: 0.5-4(l/min) ~ 5-40(l/min) , PNP/NPN open collector 2 outputs , Port sizes: 3/8, 1/2, 3/4, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, GX, IFW/PFW 3/4INCH ALL OTHERS, 1.25663

Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for high temperature fluids , Integrated display type , Temperature range: 0 to 90C , Flow rate range: 0.5-4(l/min) ~ 5-40(l/min) , PNP/NPN open collector 2 outputs , Port sizes: 3/8, 1/2, 3/4, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, FB, IFW/PFW 1/2INCH NPT VERSION, 1.80779

Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for high temperature fluids , Integrated display type , Temperature range: 0 to 90C , Flow rate range: 0.5-4(l/min) ~ 5-40(l/min) , PNP/NPN open collector 2 outputs , Port sizes: 3/8, 1/2, 3/4, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, FB, IFW/PFW 1/2INCH NPT VERSION, 1.80779

Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for high temperature fluids , Integrated display type , Temperature range: 0 to 90C , Flow rate range: 0.5-4(l/min) ~ 5-40(l/min) , PNP/NPN open collector 2 outputs , Port sizes: 3/8, 1/2, 3/4, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, GB, IFW/PFW 3/4INCH NPT VERSION, 1.88967

Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for high temperature fluids , Integrated display type , Temperature range: 0 to 90C , Flow rate range: 0.5-4(l/min) ~ 5-40(l/min) , PNP/NPN open collector 2 outputs , Port sizes: 3/8, 1/2, 3/4, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, GB, IFW/PFW 3/4INCH NPT VERSION, 1.45505

Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for high temperature fluids , Integrated display type , Temperature range: 0 to 90C , Flow rate range: 0.5-4(l/min) ~ 5-40(l/min) , PNP/NPN open collector 2 outputs , Port sizes: 3/8, 1/2, 3/4, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, GB, IFW/PFW 3/4INCH NPT VERSION, 1.61671

Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for high temperature fluids , Integrated display type , Temperature range: 0 to 90C , Flow rate range: 0.5-4(l/min) ~ 5-40(l/min) , PNP/NPN open collector 2 outputs , Port sizes: 3/8, 1/2, 3/4, DIGITAL FLOW SWITCH,COMBO UNIT, INSTRUMENTATION, IFW/PFW FLOW SWITCH, 2X, IFW/PFW NO SIZE ALL OTHER, 2.14500

(110 MPa) 24000 psig (165 MPa) 40 psig (276 MPa) Proof pressure Burst pressure 40 to 160F (40 to 71C) (No freezing) 3) 0.06 Bubble tight NPT 1/4 inch, MS33649 Option: Panel mount 5.07 lbs (2.3 kg) 4) Ambient and operating temperature Cv Leak rate Connections Installation Mass 1) Not available for material code B 2) Source pressure 6000 psig (41.4 MPa) for PEEK seat. 3) 14 to 194F (10 to 90C

sResponse timeHysteresisPower supply voltageResistance--Real-time flow rateAccumulated flowSwitch outputAccumulated pulse outputEnclosureOperating temperature rangeWithstand voltageInsulation resistanceVibration resistanceImpact resistanceNoise resistancePF2W720TWater, Mixture of water (50%) and ethylene glycol (50%)1.7 to 17.0 l/min1.7 to 17.0 l/min2 to 16 l/min0.1 l/min0.1 l/pulse0 to 90C

sResponse timeHysteresisPower supply voltageResistance--Real-time flow rateAccumulated flowSwitch outputAccumulated pulse outputEnclosureOperating temperature rangeWithstand voltageInsulation resistanceVibration resistanceImpact resistanceNoise resistancePF2W704TWater, Mixture of water (50%) and ethylene glycol (50%)0.35 to 4.5 l/min0.35 to 4.5 l/min0.5 to 4 l/min0.05 l/min0.05 l/pulse0 to 90C