Note 2) Determination of pressure (P) when making intermediate stop P Ps P > Ps (Refer to page 1529.) (For intermediate stops, refer to page 1527.)
Type 2-Port Solenoid Valve JSXM Series p. 39 JSX20U, 30U Port Size 1/8, 1/4, 3/8 Body Material Brass p. 19 JSX20U, 30U Port Size 1/8, 1/4, 3/8 Body Material Aluminum p. 21 Glossary of Terms Bracket Options p. 23 How to Order p. 39 Flow Rate Characteristics, Common Specifications p. 40 Construction p. 41 Dimensions p. 42 Modular Connection Examples p. 44 Spacer / Spacer with Bracket
V: Power supply voltage Power consumption P: 7 [kW] Q = P = 7 [kW] P Cooling capacity = Considering a safety factor of 20%, 7 [kW] x 1.2 = 8.4 [kW] Power consumption w Derive the heat generation amount from the power e Derive the heat generation amount from the output. supply output. Output (shaft power etc.)
IPX4 (400 V as standard) HRS100/150 Standard type 1.0 5 to 35 V V (400 V as standard, 200 V as an option) HRSH090 Inverter type 0.1 5 to 40 V Indoor use (Only 200 V as an option) (400 V as standard, 200 V as an option) Outdoor installation IPX4 HRSH Inverter type 0.1 5 to 35 V V V V V (Only 200 V as an option.
CNS CLS CLQ MLGP RLQ MLU Selection Conditions/Table (1) ML1C DVertical Upward facing Downward facing Horizontal -X l1 = Eccentric distance 20l2 = Distance between the plate and load center of gravity m Data Mounting orientation m m l1 = Eccentric distance Maximum load speed V 201 to 400 mm/s 50 to 200 mm/s 50 to 200 mm/s 201 to 400 mm/s 50 to 200 mm/s 201 to 400 mm/s Graph (Slide bearing
CNS CLS CLQ MLGP RLQ MLU Selection Conditions/Table (1) ML1C DVertical Upward facing Downward facing Horizontal -X l1 = Eccentric distance 20l2 = Distance between the plate and load center of gravity m Data Mounting orientation m m l1 = Eccentric distance Maximum load speed V 201 to 400 mm/s 50 to 200 mm/s 50 to 200 mm/s 201 to 400 mm/s 50 to 200 mm/s 201 to 400 mm/s Graph (Slide bearing
Note 2) 400 V type is provided with an earth leakage breaker -B as standard.
Refer to p.3.4-14. Auto Switch Mounting Bracket Part No.
Magnet: None, Mounting: B (Basic Style), Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 25mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: P (Air Pressure Lock-up)
Magnet: None, Mounting: B (Basic Style), Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 50mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: P (Air Pressure Lock-up)
Magnet: None, Mounting: B (Basic Style), Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 125mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: P (Air Pressure Lock-up)
Magnet: None, Mounting: B (Basic Style), Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 250mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: P (Air Pressure Lock-up)
Magnet: None, Mounting: B (Basic Style), Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 75mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: P (Air Pressure Lock-up)
Magnet: None, Mounting: B (Basic Style), Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 450mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: P (Air Pressure Lock-up)
Magnet: None, Mounting: B (Basic Style), Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 100mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: P (Air Pressure Lock-up)
Magnet: None, Mounting: B (Basic Style), Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 150mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: P (Air Pressure Lock-up)
Magnet: None, Mounting: B (Basic Style), Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 200mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: P (Air Pressure Lock-up)
Magnet: None, Mounting: B (Basic Style), Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 500mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: P (Air Pressure Lock-up)
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification