SMC Corporation of America
Elite Part Number Search
Search Results "CLSB160-400-D"

Foundation bolt L1 (mm) Nominal thread size d M16 L1 R Applicable model d1 S L Part No. (Approx.) (Approx.) FGF-OP05 Hexagon nut d FGF1-20 16 40 71 31.5 400 R d1 FGF3-40 AI-3S M20 20 50 90 40 500 FGF5-60 S Note) 3 foundation bolts are required per filter unit. If ordering only foundation bolts, order 3 bolts using the above part number.

Total stroke time t Stroke L Stroke mm Speed d% d% Speed at the end Stroke Speed at the end u Time s SOL: ON (OFF) IV Air Cylinder Drive Systems Total Stroke Time and Speed at the End Series SV Series SV3000 Applicable bore size: 50, 63, 80, 100 Applicable related components Total stroke time s Tubing Speed controller Solenoid valve Silencer 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 400

C D 15 (mm) Auto switch model A D-F9 B C D D-A9 D-F9 D-A9 D-F9 D-A9 D-F9 Bore size (mm) 17.5 15 D-A9 21.5 76.5 72.5 56.5 60.5 Note) Auto switches cannot be installed in Area C in the case of 15. 25, 32 (mm) A D-Y5 D-Y7 D-Y7W B C D Auto switch model D-Y5 D-Y7 D-Y7W D-Y5 D-Y7 D-Y7W D-Y5 D-Y7 D-Y7W D-Z7 D-Z8 D-Z7 D-Z8 D-Z7 D-Z8 D-Z7 D-Z8 Bore size (mm) 25 22 101 103 47 47 78 78 22 32 30.5

The CLS series cylinder with lock is ideal for applications requiring intermediate and emergency stop and drop prevention. The compact lock unit is lightweight and saves space. A switch is optional on the brake cylinder so the operating state of the lock unit (brake piston) can be detected using the switch signal. By separating the lock mechanism and the brake cylinder, SMC has minimized

Magnet: None, Mounting: B (Standard), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 160mm, Thread: Rc, Stroke: 300mm

Magnet: None, Mounting: B (Standard), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 160mm, Thread: Rc, Stroke: 900mm

Magnet: None, Mounting: B (Standard), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 160mm, Thread: Rc, Stroke: 1000mm

Magnet: None, Mounting: B (Standard), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 160mm, Thread: Rc, Stroke: 100mm

Magnet: None, Mounting: B (Standard), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 160mm, Thread: Rc, Stroke: 200mm

Cylinder (Tube) Inner Diameter(φ): 160, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Magnet: None, Mounting: Standard, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 160mm, Thread: Rc, Stroke: 300mm, Option: -, Cylinder Switch Type: -, Lead Wire or Pre-wired Connector: -, Number: -, Lock Unit Built-in Magnet: -, Lock Unit Switch Type: -

Magnet: None, Mounting: Standard, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 160mm, Thread: Rc, Stroke: 900mm, Option: -, Cylinder Switch Type: -, Lead Wire or Pre-wired Connector: -, Number: -, Lock Unit Built-in Magnet: -, Lock Unit Switch Type: -

Magnet: None, Mounting: Standard, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 160mm, Thread: Rc, Stroke: 1000mm, Option: -, Cylinder Switch Type: -, Lead Wire or Pre-wired Connector: -, Number: -, Lock Unit Built-in Magnet: -, Lock Unit Switch Type: -

Magnet: None, Mounting: Standard, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 160mm, Thread: Rc, Stroke: 100mm, Option: -, Cylinder Switch Type: -, Lead Wire or Pre-wired Connector: -, Number: -, Lock Unit Built-in Magnet: -, Lock Unit Switch Type: -

Magnet: None, Mounting: Standard, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 160mm, Thread: Rc, Stroke: 200mm, Option: -, Cylinder Switch Type: -, Lead Wire or Pre-wired Connector: -, Number: -, Lock Unit Built-in Magnet: -, Lock Unit Switch Type: -

Cylinder (Tube) Inner Diameter(φ): 160, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

See the table below Belt tension Size Belt N Part number Bolts LEF25 LE-D-6-2 19.6 pull LEF32 LE-D-6-3 49.0 LEF40 LE-D-6-4 98.1 4. "Pulley plate" is installed. Bolts Size Tightening torque (Nm) M3 0.6310% M4 1.510% M5 310% 8.Troubleshooting When a fault occurs during the operation, the corresponding alarm or warning is displayed.

0 0 0 100 200 500 400 300 600 0 150 100 50 200 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] AFM40-D AFD40-D 0.02 0.02 Pressure drop [MPa] Pressure drop [MPa] P1 = 0.5 MPa P1 = 0.3 MPa P1 = 0.5 MPa P1 = 0.3 MPa P1 = 0.7 MPa P1 = 0.7 MPa 0.01 0.01 0 0 0 600 400 200 800 1000 0 100 200 500 400 300 600 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] 72 AFM20-D to AFM40-D Series AFD20-D to

IPX4 (400 V as standard) HRS100/150 Standard type 1.0 5 to 35 V V (400 V as standard, 200 V as an option) HRSH090 Inverter type 0.1 5 to 40 V Indoor use (Only 200 V as an option) (400 V as standard, 200 V as an option) Outdoor installation IPX4 HRSH Inverter type 0.1 5 to 35 V V V V V (Only 200 V as an option.

/C8 D-C73C/C80C D-B5/B6 D-B59W D-A3/A4 D-A3A/A44A D-A3C/A44C D-A7/A8 D-A7H/A80H D-A73C/A80C D-A79W D-A5/A6 D-A59W D-A9 D-A9V D-Z7/Z8 D-H7 D-H7C D-H7BAL D-H7F D-H7W D-G5/K5 D-G5BAL D-G59F D-G5NTL D-G5W/K59W D-G39/K39 D-G39A/K39A D-F7/J7 D-J79C D-F7F D-F7BAL D-F7BAVL D-F7V D-F7NTL D-F7W (V) D-F5/J5 D-F5BAL D-F5W/J59W D-F5F D-F5NTL D-G39C/K39C D-M9 D-M9V D-F9W D-F9WV D-F9BAL D-Y59A/Y7P/Y59B