Piping: Standard, Bore Size: 10mm, Port Thread: (M5 Thread-6~15mm)(Rc-20~63mm), Stroke: 150mm
Piping: Standard, Bore Size: 10mm, Port Thread: (M5 Thread-6~15mm)(Rc-20~63mm), Stroke: 300mm
With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,
With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,
With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes, from
Bore Size: 16mm, Thread Type: Bore 8-16: M Thread, Bore 20-25: Rc, Stroke: 200mm, Option: Standard (w/Urethane Bumper), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Overall Length: Standard, Bore Size: 106 (1 1/16"), Stroke: 200 (2"), Body Option: Standard (Rod End Female Thread), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in Magnet), Mounting: L (Axial Foot), Bore Size: 50mm, Thread: Rc, Stroke: 200mm, Rod Boot: None, Cushion: Air Cushion, Pivot Bracket: No Bracket, Rod End Bracket: No Bracket, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)
Mounting: Tapped on Both Sides, Bore Size: 20mm, Stroke: 200mm, Cushion: 40~63 Bore-Cushion Both Sides; 12~32 Bore-No Cushion, Connector: Connector, Cable Length: 0.5m, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -
Mounting: Basic Type, Bore Size: 50mm, Port Thread: M5x0.8 (20), Rc (25~80), Coil Scraper: Without, Stroke: 200mm, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: D (Built-in Magnet), Series: A2, Mounting: L (Axial Foot), Tube Material: Aluminum Tube, Bore Size: 80mm, Port Thread: Rc, Stroke: 200mm, Rod Boot: w/o Rod Boot, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)
Cylinder (Tube) Inner Diameter(φ): 1 1/2", Stroke(mm): 2", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Built-in Magnet, Support bracket: Both Ends Tapped, Body Options: Female
Cylinder (Tube) Inner Diameter(φ): 1 1/2", Stroke(mm): 2", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Built-in Magnet, Support bracket: Both Ends Tapped, Body Options: Female
Cylinder (Tube) Inner Diameter(φ): 1 1/16", Stroke(mm): 2", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Built-in Magnet, Support bracket: Both Ends Tapped, Body Options: Female
Magnet: Built-in, Mounting: Front Flange, Bore Size: Ø50, Port Thread: Rc, Stroke: 200mm, Rod Boot and Cushion: w/o Rod Boot (w/Standard Air Cushion), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in, Mounting: Front Flange, Bore Size: Ø32, Port Thread: Rc, Stroke: 200mm, Rod Boot and Cushion: w/o Rod Boot (w/Standard Air Cushion), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in, Mounting: Center Trunnion, Bore Size: Ø50, Port Thread: Rc, Stroke: 200mm, Rod Boot and Cushion: w/o Rod Boot (w/Standard Air Cushion), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in, Mounting: Double Clevis, Bore Size: Ø40, Port Thread: Rc, Stroke: 200mm, Rod Boot and Cushion: w/o Rod Boot (w/Standard Air Cushion), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in, Mounting: Basic, Bore Size: 50mm, Stroke: 200mm, Option: w/o Rod Boot; Air Cushion on Both Sides, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: D (Built-in), Mounting: F (Rod Flange), Bore Size: 20mm, Stroke: 200mm, Rod End Thread: Male Thread, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)