SMC Corporation of America
Elite Part Number Search
Search Results "CY3RG15-400-A93"

Lead wire length (m) Load voltage Rail mounting Direct mounting Indicator light Special function Type Electrical entry Wiring (Output) Pre-wire connector Applicable load 12 to 40 32, 40 0.5 (Nil) 3 (L) 5 (Z) None (N) AC DC In-line In-line Perpendicular Perpendicular 3-wire (NPN equivalent) IC circuit 5 V A76H A96V A96 A93V A93 A72H A73H A72 A73 A73C 200 V Grommet Reed switch Solid

IC circuit A96 A96V 5 V Yes 24 V Grommet A93V2 A93 A90 Relay, PLC 100 V 2-wire 12 V A90V IC circuit No 100 V or less 1 Although it is possible to mount water resistant type auto switches, note that the rotary actuator itself is not of water resistant construction. 2 1 m type lead wire is only applicable to D-A93. Auto switches marked with a are produced upon receipt of orders.

A93 3m . L (Ex.) A93L 5m . Z (Ex.) F9NWZ Solid state auto switches marked with a "" are produced upon receipt of order.

Operating temperature range (C) 5 to 60 Standard Strokes Bore sizes (mm) Standard strokes (mm) Max. manufacturable stroke (mm) 16 100, 200, 300, 400, 500, 600, 700 800, 900, 1000, 1200, 1400, 1600 1800, 2000 3000 20, 25, 32, 40, 50, 63 Strokes can be manufactured in 1mm increments, up to the maximum stroke.

Bearing Type: L (Ball Bushing), Bore Size: Ø40 mm, Port Thread Type: Bore 16: M5 x 0.8; Bore 20-100: Rc, Stroke: 400 mm, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L [3m]

Bearing Type: L (Ball Bushing), Bore Size: Ø40 mm, Port Thread Type: Bore 16: M5 x 0.8; Bore 20-100: Rc, Stroke: 400 mm, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L [3m], Number: 3 pcs.

Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Overall Length: Standard, Bore Size: 106 (1 1/16"), Stroke: 400 (4"), Body Option: Standard (Rod End Female Thread), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal

Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Overall Length: Z (Super Compact), Bore Size: 150 (1 1/2"), Stroke: 400 (4"), Body Option: Standard (Rod End Female Thread), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Overall Length: Standard, Bore Size: 200 (2"), Stroke: 400 (4"), Body Option: Standard (Rod End Female Thread), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Overall Length: Standard, Bore Size: 106 (1 1/16"), Stroke: 400 (4"), Body Option: Standard (Rod End Female Thread), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)

: Built-in magnet, Port thread type: Rc, Auto Switches: A93, Lead Wire Length(m): 3, The number of the switches: 2, Type of Auto Switch Mounting: Standard, Type of Mount Support: Basic type, Rod Boot: None, Custom-made Specifications: None, Locking Direction: Bidirectional

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port thread

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port thread

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port thread

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.08~0.97, Cushion: With

Auto Switches: A93, Lead Wire Length(m): 3, The number of the switches: 1, Type of Auto Switch Mounting: Standard, Lock Position: With head-end lock, Type of Mount Support: Basic type, Rod Boot: None, Custom-made Specifications: None, Lock actuation system: Non-locking type

Auto Switches: A93, Lead Wire Length(m): 3, The number of the switches: 2, Type of Auto Switch Mounting: Standard, Lock Position: With head-end lock, Type of Mount Support: Rod-end flange type, Rod Boot: None, Custom-made Specifications: None, Lock actuation system: Non-locking type