Pressure 0.7 MPa PM: Raised up to 0.43 MPa 6 x 6 pcs. 6 x 10 pcs. 6 x 8 pcs. 6 x 10 pcs. 6 x 8 pcs. 6 x 10 pcs. 6 x 10 pcs. Flow rate Q (Nl) Flow rate Q (Nl) Tube 2,000 Tube 2,000 mm 500 mm 6 x 8 pcs. 6 x 8 pcs. 500 mm 500 mm mm 6 x 6 pcs. 6 x 6 pcs. 6 x 6 pcs. 6 x 6 pcs.
Max. 3.5 151 (3 position: 159) Light Applicable heavy-duty cord 187.5 (3 position: 195) O.D. 6 to 8 (Y: 4.7 to 7) With light/surge voltage suppressor (DZ) Light Conduit terminal: Double VFS2210-T-01 02 Closed center VFS2310-T-01 02 Exhaust center VFS2410-T-01 02 Pressure center VFS2510-T-01 02 Applicable heavy-duty cord 187.5 (3 position: 195) ( ): Y, YZ O.D. 6 to 8 With light/surge voltage
01 DIN Terminal (D): 10-SYJ5143-D-01 M8 connector (WO): 10-SYJ5143-WO-01 Approx. 300 (Lead wire length) Applicable cable O.D. 3.5 to 7 82.9 82.6 MAX.10 75.4 50.1[57.1] 64.1 34.7 54.6 M8 x 1 49 37.1 61.2[68.2] Approx. 300 (Lead wire length) 6 Pg7 6 6 6 73.5[75.7] 63.7[65.9] 83.5 65.2 72.6 58.7 0.5 45.5 45.5 45.5 45.5 17 17 17 17 17 17 17 17 42.7 0.5 0.5 6 6 6 6 0.5 8.5 8.5 8.5 8.5 21.5 21.5
Y300 Y400 Y500 Spacer (5) (6) 01 (02) AKM2000(01) 02 AKM4000(02) 03 AKM3000Check valve (6) IS1000M-20 IS1000M-30 IS1000M-40 IS1000M-50 Pressure switch 01 (02) Y210(01) 02 Y410(02) 03 Y510Y310(02) 03 Y110-M5 (5) (6) T-interface Attachment 02 03 04 (6) VHS40-06 01 02 VHS20VHS30VHS4002 03 Residual pressure relief 3 port valve 02 03 04 06 E500-06 02 03 04 E200E30001 02 03 (6) E400Piping adapter
VHS3003 VHS2002 VHS30-03 VHS4002 Note 6) 01 02 02 03 06 Piping adapter E100-M5 E200-02 E300-03 E300-03 E400-04 E500-06 E60010 E60006 E60006 10 10 03 04 04 06 Note 6) 02 01 02 02 Pressure switch 03 IS1000E-20 02 IS1000E-30 03 IS1000E-30 03 IS1000E-40 04 with piping adapter 03 04 04 06 Note 6) 01 01 01 02 03 Y14-M5 Cross interface Y24-02 Y34-02 Y34-02 Y44-03 Y54-04 Note 1) in part numbers
1.94) 6 x 1m 6 x 1m 8 x 1m AS3001F-08 (Cv = 0.56) 8 x 1m AS3001F-08 (Cv = 0.56) AS3001F-06 (Cv = 0.36) AS3001F-06 (Cv = 0.36) AN101-01 (Cv = 1.11) AN110-01 (Cv = 1.94) 10 x 1m AS4001F-10 (Cv = 0.89) 10 x 1m AS3001F-08 (Cv = 0.56) 12 x 1m AS4001F-10 (Cv = 1.17) 6 x 1m 6 x 1m AS3001F-06 (Cv = 0.36) AS3001F-06 (Cv = 0.36) AN200-02 (Cv = 1.94) AN110-01 (Cv = 1.94) 10 x 1m AS4001F-10 (Cv = 0.89
-M-01 DIN terminal (D, Y): 10-SYJ5143-01 M8 connector (WO): 10-SYJ5143-WO-01 D Y Applicable cable O.D. 3.5 to 7 Approx. 300 (Lead wire length) 82.9 Max. 10 50.1 [57.1] 75.4 64.1 34.7 M8 x 1 54.6 49 37.1 61.2 [68.2] Approx. 300 (Lead wire length) 6 Pg7 6 6 6 73.5 [75.7] 63.7 [65.9] 83.5 82.6 65.2 72.6 58.7 0.5 45.5 45.5 45.5 45.5 17 17 17 17 17 17 17 17 42.7 0.5 0.5 6 6 6 6 0.5 8.5 8.5 8.5
Note 4) Float type auto drain AD37 Y300 AD47 Y400 Spacer Note 5) Note 6) AKM2000AKM3000(01) 02 AKM4000(02) 03 01 (02) Check valve IS1000M-30 IS1000M-40 IS1000M-50 IS1000M-20 Note 6) Pressure switch Y210Y310(01) 02 Y410(02) 03 Y510Y110-M5 01 (02) Note 5) Note 6) (02) 03 T-interface Attachment 3-port valve for residual pressure release 02 03 04 Note 6) VHS2000VHS3000VHS401 02 02 03 02 03
SYJ5 40-M-01 3 4 5 DIN terminal (D): SYJ5 40-D-01 3 4 5 M8 connector (WO): SYJ5 40-WO-01 3 4 5 Applicable cable O.D. 3.5 to 7 Approx. 300 (Lead wire length) 82.9 Max. 10 75.4 50.1 [57.1] 64.1 34.7 49 M8 x 1 54.6 37.1 61.2 [68.2] Approx. 300 (Lead wire length) 6 Pg7 6 6 6 65.8 103.4 [107.8] 59.3 123 [127.4] 45.5 45.5 45.5 45.5 18.1 43.3 17 17 17 17 17 17 17 17 141.2 121.2 143 6 8.5 6 6 6 48.9
FF00 5 01 02 004B 0001 01 02 01 Acquires the INP signal information. Acquires the information repeatedly until the received information shows that the INP is "1". 6 Repeat steps 5-6 When INP becomes "1", the Return to Origin operation is completed.
02 01 02 01 02 01 02 01 02 Light/Surge voltage suppressor (At TZ) Applicable cable O.D. 6 to 8 Applicable cable O.D. 2.3 to 2.8 Light/Surge voltage suppressor (At EZ) Light Light Max. 10 Max. 10 Other dimensions are the same as the grommet type.
13 (13) AS221FS-01-04 (S) 4 8.2 AS221FS-01-06 (S) 6 10.4 14 (13) AS221FS-01-08 (S) 8 13.2 22.4 29.5 14.2 15 (14) AS221FS-01-10 (S) 10 15.9 25.3 32.4 15.6 16 (15) AS221FS-02-23 (S) 3.2 12 19.1 26.2 19.1 43.9 42.4 40.8 39.3 13.3 20 21.5 6.5 15 1/8 13 (12.7) 7.2 20.9 30.2 (30.3) 22.6 49.7 48.3 44.2 42.8 13.3 21.5 24 7.8 16.2 23 (24) AS221FS-02-04 (S) 4 8.2 AS221FS-02-06 (S) 6 10.4 23.4 32.7
screw-in connection Model A 58.5 41.5 29.5 6 12.8 3.2 12 58.5 41.5 29.5 6 12.8 3.2 12 61 41.5 29.5 6 12.8 3.2 12 61 41.5 29.5 6 12.8 3.2 12 66 44.5 30.5 6 12.8 4.2 12 70 44.5 30.5 6 12.8 4.2 12 74.5 54 39 8 13.7 4.2 17 79.5 54 39 8 13.7 4.2 17 B C D E F G H ZQ ZH05DS-06-01-06 ZH05DL-06-01-06 ZH07DS-06-01-06 ZH07DL-06-01-06 ZH10DS-06-01-08 ZH10DL-06-01-08 ZH13DS-08-02-10 ZH13DL-08-02-10 14.2
M plug connector 2 position double: VZS2250-M(Z)-01 3 position closed center: VZS2350-M(Z)-01 3 position exhaust center: VZS2450-M(Z)-01 3 position pressure center: VZS2550-M(Z)-01 DIN terminal 2 position double: VZS2250-D(Z)-01 3 position closed center: VZS2350-D(Z)-01 3 position exhaust center: VZS2450-D(Z)-01 3 position pressure center: VZS2550-D(Z)-01 Applicable cable O.D.: 3.5 to 7 MAX
(mm) Applicable fitting size 4 6 8 10 12 Applicable tubing O.D. (mm) Connection threads Model Model 4 6 8 10 12 KGL04-99 KGE04-01 R 1/8 4 KGL06-99 -02 R 1/4 KGL08-99 KGE06-01 R 1/8 KGL10-99 6 -02 R 1/4 KGL12-99 -03 R 3/8 KGE08-01 R 1/8 Plug-in Reducer KGR -02 8 R 1/4 -03 R 3/8 Applicable tubing O.D.
AD17-A AD27-A AD37-A AD47-A Spacer Y100-A Y200-A Y300-A Y400-A Y500-A Y600-A Spacer with bracket Y100T-A Y200T-A Y300T-A Y400T-A Y500T-A Y600T-A Check valve 5 6 AKM2000-01-A (02)-A AKM3000-(01)-A 02-A AKM4000-(02)-A 03-A Pressure switch 6 IS10M-20-A IS10M-30-A IS10M-40-A IS10M-50-A IS10M-60-A T-spacer 5 6 Y110-M5-A Y210-01-A (02)-A Y310-(01)-A 02-A Y410-(02)-A 03-A Y510-(02)-A 03-A Y610
L (10) 8 Dimensions (24) (35) Applicable fittings size d 4 Model A L D 10-KQ2P-04 16 32 6 6 10-KQ2P-06 18 35 8 8 10-KQ2P-08 20.5 39 10 10 10-KQ2P-10 22 43 12 12 10-KQ2P-12 24 44.5 14 10-KQ2P-01 16 31.5 5 10-KQ2P-03 16 32 6 10-KQ2P-07 18 35 8.5 10-KQ2P-09 20.5 39 10 10-KQ2P-11 22 43 11.5 5.5 Rail mounting pitch 12.5 0 1 2 3 4 5 6 7 8 9 No.
X Port size) Sysytem Figure Silencer System Solenoid valve Speed controller 4 X M5 6 X M5 6 X 1/8 6 X M5 AS1301F-M5-04 A SYJ3000 M5 X 0.8 (S = 1.8mm2) AS1301F-M5-06 B q AN120-M5 (S=5mm2) AS2301F-01-06 C 6 X M5 AS2001F-06 D w 1.2-9 Series SYJ3000 How to Order Bracket Light and surge voltage suppressor Configuration S Z R U Without light and surge suppressor With surge suppressor With light
VZA4221-01 VZA4321-01 VZA4421-01 VZA4141-1-01 VZA4141-1-02 VZA4141-2-01 VZA4141-2-02 VZA4241-1-01 VZA4241-1-02 VZA4241-2-01 VZA4241-2-02 VZA4341-1-01 VZA4341-1-02 VZA4341-2-01 VZA4341-2-01 VZA4441-1-01 VZA4441-1-02 VZA4441-2-01 VZA4441-2-02 Single Double Closed center Exhaust center 0.44 0.44 0.44 0.44 0.25 0.25 0.25 0.25 1.7 1.7 1.7 1.7 0.49 0.49 0.47 0.47 0.14 0.14 0.15 0.15 2.0 2.0 1.9