SMC Corporation of America
Elite Part Number Search
Search Results "HRS018-W-20-MT"

Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: T (High-lift Pump)

Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: BT (B + T)

Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: BM (B + M)

Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: B (Earth Leakage Breaker)

Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: M [Applicable to DI Water (Deionized Water) Piping]

Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: BM (B + M)

Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: JT (J + T)

Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: BM (B + M)

Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: J (Automatic Water Supply Function)

Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: BJ (B + J)

Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: BT (B + T)

Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: M [Applicable to DI Water (Deionized Water) Piping]

Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance.  An angled supply port facilitates the supply of circulating fluid, even when units are stacked.  A large digital display provides a clear view of the current and set values.  The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter

ML2B32 15N Va 0.25m/s 0.5MPa L1 0.05m L2 0.05m W W 1 L L1 W W W M We M3 V M1 V <> W max=60N( Va P 19) a1= W = 15 =0.25 W max 60 M 2 max=2Nm( Va P 19) a2= M = 0.75 =0.375 M max 2 <> We=1.410VaW=1.4100.2515=52.2N M max=3.5Nm( V=1.4Va) M 3 WeL 1 =52.50.05 1 =0.88Nm 3 3 a3= M 3 = 0.88 =0.25 M 3max 3.5 M max=12Nm( V=1.4Va) M 1 WeL 1 1 =52.50.05 1 =0.88Nm 3 3 a4= M 1 =

.5-18 5.8.4 Command:LOC Key-lock setting (R) .5-19 5.8.5 Command:LOC Key-lock setting (W).5-20 5.8.6 Command:STR Saves data (W) .5-21 5.9 Negative response.5-22 Chapter 6 Communication alarm function . 6-1 6.1 Communication alarm occurs .6-1 6.2 Communication alarm reset.6-2 6.3 Setting and checking.6-2 6.3.1 Setting and checking items.6-2 6.3.2 Setting and checking.6-3 HRSH Series HRX-OM-R028

. 5-18 5.8.4 Command:LOC Key-lock setting (R) . 5-19 5.8.5 Command:LOC Key-lock setting (W) . 5-20 5.8.6 Command:STR Saves data (W) . 5-21 5.9 Negative response . 5-22 Chapter 6 Communication alarm function . 6-1 6.1 Communication alarm occurs . 6-1 6.2 Communication alarm reset . 6-2 6.3 Setting and checking . 6-2 6.3.1 Setting and checking items . 6-2 HRS090 Series HRX-OM-T004 Contents

Handling Technical Material Be sure to read before handling brake positioning system (CE2 + CEU2). 682 CE2 Series Prior to Use Example of Recommended Pneumatic Circuit Horizontal mounting Vertical flat mounting Vertical overhead mounting W W CEP1 CE1 CE2 CE2 ML2B W Note) In the case of light load, regulate head side supply pressure.

Cooling Capacity: Cooling Capacity: 1500/1700W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: Rc, Option: -

Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: Rc

Solenoid specifications Apparent power VA Inrush Energized Power consumption W (energized) Temperature increase C (rated voltage) 8 6.5 8 11 9.5 11.5 Symbol Frequency Hz 50 66 (60) 20 60 57 (51) 15 50 93 25 60 79 20 Model Power supply 55 45 50 60 50 55 OUT AC VXZ22 DC AC IN VXZ23 DC Note 1) Reset voltage is 20% or more of rated voltage for AC, and 5% or more of rated voltage for DC.