SMC Corporation of America
Elite Part Number Search
Search Results "HRSH090-W-20-MS"

mA Load impedance 50 to 600 Accumulated pulse output wiring examples NPN 2 output type LFElAlll NPN + Analog output type LFElClll/LFElDlll Max. 28 V, 80 mA Black OUT1 Load White OUT2 (LFE A only) Load 0 V or Blue DC () 50 ms 50 ms PNP 2 output type LFElBlll Brown DC (+) Black OUT1 Max. 80 mA Load White OUT2 0 V or Load 50 ms 50 ms * When accumulated pulse output is selected, the indicator

Connect the motor power supply input terminal (U, V, W) to the driver power terminal (U, V, W).

Output r8lponse Grommet Grommet Grommet Lead wire entry 1 mS or less 1 mS or less 1 mS or less " ~ ResponseUme ... ...

mA Fault current (FDE): 3.9 mA FOUNDATION fieldbus function block execution times ND9000F AO 20 ms AI 20 ms PID 20 ms DO 20 ms DI 15 ms IS 15 ms OS 15ms 7 ND90 71 en 7 Approvals Table 1 Approvals and electrical values, HART Certificate Approval Electrical values ATEX ND_X VTT 09 ATEX 033X VTT 09 ATEX 034X II 1G Ex ia IIC T6...T4 Ga II 1D Ex ta IIIC T90 C Da II 2 G Ex ib IIC T6...T4 Gb II

-15% Input Impedance > 800 kOhms Input Current 0.24mA / 240V AC~ Input Voltage 100 240V AC~, +10% -15%, 50 60 Hz Operation Indication Liquid Crystal Display Isolation Circuit None None Response Time (I09 I12) 20 40 ms 20 40 ms Response Time (I01 I08) 10 20 ms 10 20 ms Description AC Input Specication Description Sink (Common) Source (+ Common) 6 PneuAlpha Hardware Specification 2 Table 2.5

p 1o 12 stalons Lateral Plug.in Style Manifold series VQCI 000/20044000 r t Fast response times and long service life VQCl100: 10 ms 2 ms; 200 million cycles VQC2100: 20 ms 2 ms; 200 million cycles VQC4100: 17 ms 3 ms; 100 million cycles ( ( I T CE compliment " , t 4-position dual 3-pod valves for independent control of A & B ports Availabe conf igurations IN.C.A.C.], lN.O /N.O l, and [N.c

voltage 90 to 264 VAC 21.6 to 26.4 VDC 90 to 264 VAC 21.6 to 26.4 VDC 90 to 264 VAC 21.6 to 26.4 VDC 90 to 264 VAC 21.6 to 26.4 VDC Power consumption 20 VA or less 10 W or less 20 VA or less 10 W or less 20 VA or less 10 W or less 20 VA or less 10 W or less Between case and AC line: 1500 VAC for 1 min.

time 1 : 1 ms Output delay WCDT in : Input delay + 12 ms 1 + 12 ms WCDT out : Output delay One Fault delay time (OFDT) IN 1oo2 : WCDT in One Fault delay time (OFDT) IN 1oo1 : 122 ms One Fault delay time (OFDT) OUT M : WCDT out 1 (OFDT) OUT Z1..3 : 30 ms One Fault delay time Device acknowledge time (DAT) : 20 ms -SFRT/ 1 110 No.EX##-OMY0006CN 24.H IoT IoTIoT SMC 1.

Standard With power saving circuit 0.4 W 0.1 W 0 W 62 ms 372 Series 10-SYJ3000/5000/7000 Specific Product Precautions 4 Be sure to read this before handling. Refer to page 1382 for Safety Instructions and pages 677 to 683 for 3/4/5 Port Solenoid Valve Precautions.

Applied voltage 24 V 0 V Standard With power saving circuit 0.4 W 0.1 W 0 W 62 ms 1-5-76 77 Series SYJ3000/5000/7000 Specific Product Precautions 4 Be sure to read before handling. Surge Voltage Suppressor How to Use DIN Terminal (There is no S type because the generation of surge voltage is prevented by a rectifier.)

Applied voltage 24 V Please be careful not to reverse the polarity, since a diode to prevent the reversed current is not provided for DC voltages other than 24 and 12 VDC. 0 V Standard With power saving circuit 0.4 W The WA-type valve cannot be grounded. 0.1 W 0 W 62 ms 643 Series 10-SYJ300/500/700 Specific Product Precautions 4 Be sure to read this before handling.

(For details, refer to page 4-4-25.) 4-4-20 21 3 Port Pilot Operated Solenoid Valve Rubber Seal Series SYJ500 Construction q e r t w y q e r t w y N.C. N.O.

or less (Response time selections with anti-chattering function: 20 ms, 160 ms, 640 ms, 1280 ms) Residual voltage Response time ZL With short circuit protection Short circuit protection ZY For details, refer to Best Pneumatics Vol. 16.

0, Metal joint q, w, Terminal block i, O-ring e, r, t, y, u, Receptacle assembly Plug-in type 04 06 VFR5000-20-1AManifold block assembly !0 04 06 Manifold block !0, Metal joint q, w, O-ring e, r, t, y, u Non plug-in type End plate (U) !1, Metal joint q, w End plate (U) !1, Metal joint q, w End plate (D) !2, Metal joint q, w, O-ring e, r, t, y, u End plate (D) !

Set the connection range of PF2D5. 0: 4 L 1: 20 L 2: 40 L rAnG (PF2D5, Selection of connection range) Y U8 0x00 3 R/W (0) 0: PFA (PF2A5) 1: PFW (PF2W5) 2: PFd (PF2D5) 3: USEr (User setting) 4 R/W Setting of connection product Y U8 0x01 (1) Setting of connection sensor (For PF3W5) Y U8 0x00 0: FloW 1: tEMP 5 R/W (0) Unit (Selection of display unit, for PF2A5) Y U8 0x00 0: L 1: Ft 6 R/W (0)

W-AREA1 (-) (+) WAREA ON (mm) W 1W 2 WAREA ON *W 1W 2 PARA W 1=W 2=0 WAREA OFF) W-AREA2 W-AREA2 (-) (+) ORG Correct Link Offset () Sensor type Sensor type () Option 1 Option 1 () Undefine No. 11 Undefine No. 11 () Undefine No. 12 Undefine No. 12 () *1 -45- 10.3 () ORIG direction ORIG direction 12 1CW [CW] 2CCW [CCW] ORIG mode Return to origin mode 12 1[] 2[SW]

H O W T O O R D E R MXF S L I D E TA B L E MXF N O O F S W I T C H E S ...2 Pieces S ...1 Piece n ...n Pieces T Y P E O F A U T O S W I T C H E S See Accessories Section B O R E S I Z E S T R O K E ( M M) 8 10, 20, 30 12 20, 30, 50 16 30, 50, 75 20 30, 50, 75, 100 D I M E N S I O N S S E E N E X T P A G E Courtesy of Steven Engineering, Inc. !

Max.120'F(50'C) 2position : 20 ms or less 3position : 50 ms or less (70 PSI) Operating pressute range Ambient and fluid temPerature Flesponse time Max.

Horizontal 20 Lateral load 100% 10 Lateral load 50% W 5 Horizontal empty weight deflection 2 Lateral empty weight deflection 1 Load point distance 0.5 Figure 2.

Applicable Cylinders Weight (g) Cylinder series Bore size (mm) D-G5NB Auto switch model CDM2-Z, CDM2, CDBM2, CDVM3, CDVM5, CDLM2, CDLG1, MLGC CDG1-Z, CDG1 CDA2-Z, CDA2, CDBA2, CDV3, CDVS1, CDL1 MGC, MGG 20, 25, 32, 40 3 m (L) 79 Lead wire length 20, 25, 32, 40, 50, 63, 80, 100 5 m (Z) 125 40, 50, 63, 80, 100 20, 25, 32, 40, 50 Operating Range Bore size (mm) 20 Cylinder series 35 25 40 32