Bracket mounting inserts found on the standard ISE20B are omitted as well.  25A-ISE20B is UL/CSA, CE and RoHS compliant, with an IP65 enclosure rating.

The ISE20B-S is a digital pressure sensor with all standard features of the ISE20B, while integrating an M12 connection. M12 permits a stable connection for sensor installations outside a cabinet. The sensor has an informative, easy to read 3 screen, 3 color display.

adapter + Front protective cover M5 female thread/Rear ported D Note 3) M5R Piping port R1/8/Side ported 01 DIN rail adapter Note 5) R1/8 Piping adapter R Note 4) NPT1/8/Side ported N01 Note 3) Not available for piping specifications of 01 and N01.

D E F G H I ZS-31-X188 20 9 R1/8 R1/8 14 1.5 ZS-31-X189 20 9 NPT1/8 NPT1/8 14 1.5 ZS-31-X175 29 13 R1/4 R1/4 17 1.6 ZS-31-X186 29 13 NPT1/4 NPT1/4 17 1.6 -14No.PS-OMG0006-D Revision history A: For B: Complete revision C: Contents revised in several places. D: Contents revised in several places.

-100 kPa 100 kPa For positive pressure -0 to 1 MPa 0 1 MPa -0.1 MPa -13No.PS-OMG0004-D Dimensions PSE54(A)M3 M5 PSE54(A)-M3 PSE54(A)-M5 A 10.8 11.5 B 3 3.5 PSE54(A)01 N01 PSE54(A)R04 R06 PSE54(A)-R04 PSE54(A)-R06 A 4 6 B 18 20 PSE54(A)-IM5 PSE54(A)-IM5H -14No.PS-OMG0004-D Revision history A: For B: Complete revision C: Limited warranty and Disclaimer and measurement laws are added.

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Connector Type: S (M12 Connector Type), Bracket: None, Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate)

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover)

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: w/o Lead Wire, Bracket: A1 [Bracket A, Vertical Mounting (ZS-46-A1)]

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A1 [Bracket A, Vertical Mounting (ZS-46-A1)]

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A2 [Bracket B, Horizontal Mounting (ZS-46-A2)]

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: B [Panel Mount Adapter, (ZS-46-B)]

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: None, Operation Manual: Y (w/o Operation Manual, w/o Calibration

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: w/o Lead Wire, Bracket: A2 [Bracket B, Horizontal Mounting (ZS-46-A2)]

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A1 [Bracket A, Vertical Mounting (ZS-46-A1)], Operation Manual

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: D [Panel Mount Adapter + Front Protection Cover, (ZS-46-D)],

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: w/o Lead Wire, Bracket: None, Operation Manual: K (Operation Manual, Calibration Certificate)