Pressure Range: ISE70 (0 to 1 MPa), Piping: F02 (G 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: B (Bracket B)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: B (Bracket B)
Pressure Range: ISE71 (0 to 1.6 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)
Pressure Range: ISE70 (0 to 1 MPa), Piping: F02 (G 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m)
For vacuum/ compound pressure ZSE30A 01 N M ISA2 Option 3 Note) Calibration certificate Nil Y K T Note) Operation manual ISE35 Symbol Rated pressure range ZSE30A ZSE30AF 0 to 101 kPa 100 to 100 kPa PSE Piping specifications IS 01 Note) All texts in both English and Japanese.
Single foot: Cl85Nl lL (With mounting bracket) (W) LT NH LT (XS) 2 x AB Double foot: Cl85Nl lM (With mounting bracket) (W) LT 4 x AB UR NH LT (XL + Stroke) LS + Stroke AV TR US AO [mm] Bore size AB AO AV LS LT NH TRJS14 UR US (W) (XL) (XS) 8 4.5 5 11 68 3.2 16 25 26 35 12.8 73 23.8 10 4.5 5 11 68 (75) 3.2 16 25 26 35 12.8 73 (80) 23.8 12 5.5 6 14 78 (82) 4 20 32 33 42 18 86 (90) 32 16 5.5
Bracket A Bracket B [F 0] Display units, switch output specifications and diagnostic information selection function ISE70(G): 0.500 MPa/ISE71: 0.800 MPa/ ISE75G: 1.000 MPa/ISE76G: 2.50 MPa/ ISE77G: 5.00 MPa/ISE78G: 8.00 MPa Pressure setting Cross recessed round head screw: Nominal size M4 x 6L Cross recessed round head screw: Nominal size M4 x 6L Item Default setting ISE70(G): 0.050 MPa/ISE71
1 y r i e Component Parts Description Material Material Note Note Description No. q w e r t y u No. i o !0 !1 !2 !
Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket B, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: None
Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket B, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: Bracket B, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -