Pressure Range: 0 to 2 MPa, Piping: Rc 1/4, Orifice: None, Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 2 MPa, Piping: Rc 1/4, Orifice: None, Unit Specification: SI Unit Only, Lead Wire: -, Bracket: -, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 2 MPa, Piping: Rc 1/4, Orifice: None, Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -

Output erea mapping Output data offset offset MSB 7 LSB (Word) (Byte) 0 QBn+0 OUT7 OUT1 OUT0 QWn QBn+1 OUT15 OUT9 OUT8 Input mapping (Mirror data of the output data, EX12-SDN1/-X2) Input data offset offset MSB 7 LSB (Word) (Byte) 0 IBn+0 (OUT7) (OUT1) (OUT0) IWn IBn+1 (OUT15) (OUT9) (OUT8) -20No.EX-OME0015-F Output number assignment Combinations of the output data and the valve manifold

Brown SW1_OUT Power supply(+) Red Load 12 to 24 VDC White SW2_OUT Power supply(GND) Black Load MSB 10bit White Gray SW3_OUT Load 9bit Brown Black SW4_OUT Load 8bit Yellow Connected to power supply (GND) Main Circuit 7bit Green 6bit Light green Output power supply voltage to electro-pneumatic regulator Electro-pneumatic regulator Brown 5bit Sky Blue Output signal to electro-pneumatic regulator

White SW2_OUT power supply(GND) Black Load Gray SW3_OUT MSB 10bit White Load Black SW4_OUT Static Electricity Elimination Equipment Reduced-wiring Fieldbus System 9bit Brown Load + 8bit Yellow 12 to 24 VDC Blue SW-DC(GND) Note 1) 7bit Green Main Circuit 6bit Light green Brown Output power supply voltage to electro-pneumatic regulator Electro-pneumatic regulator 5bit Sky blue Black Output

VALUE 1 0 0 1 1 0 0 1 1 0 SIGNAL MSB 10bit 9bit 8bit 7bit 6bit 5bit 4bit 3bit 2bit LSB 1bit INPUT ON OFF OFF ON ON OFF OFF ON ON OFF By inputting 12-24VDC between common and each signal wire, input states becomes ON.

(The 4 MSB should always be 0). If the PLC allows a user to enter the position in units, for example, millimeters, it is the responsibility of the PLC program to convert the position in millimeters to the appropriate count value.

Content Diagnostic type Byte 0 Station status 1 Byte 1 Station status 2 Byte 2 Station status 3 Standard diagnostic data Byte 3 Master PROFIBUS DP address Byte 4 Manufacturer ID (MSB: 14h) Byte 5 Manufacturer ID (LSB: 11h) Byte 6 Header Byte 7 System diag.1 Byte 8 System diag.2 Byte 9 System diag.3 System diagnostic data Byte 10 System diag.4 Byte 11 Reserved : : Byte 18 Reserved Byte 19

GUI : Graphical User Interface I/O : Input/Output I/F : Interface MSB : Most Significant Bit ASCII : American Standard Code for Information Interchange BCD : Binary-coded decimal MFC : Microsoft Foundation Class API : Application Programming Interface PLC : Programmable Logic Controller PC : Personal computer COM : Computer on Module RS-485 : Recommended Standard 485 USB : Universal Serial

MSB LSB 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Data instruction 2 Data instruction 1 Bit 7 to 0Data instruction 1 0None 1TH1(circulating fluid return temp) Bit 15 to 8Data instruction 2 0None 1TH1(circulating fluid return temp) Example) Display the circulating fluid return temperature When 0001h is entered to the address 000F, the circulating fluid return temperature is displayed in 0009h.

Type: Pressure Switch, Fluid Type: Air, Maximum Pressure Rating: 1MPa, Minimum Pressure Rating: 0kPa, Sensor, Monitor Structure: [Integrated Type] Integrated shape, Output Method: Switch, Pipe Port Type: [Threads] Male thread, Plumbing Thread Type: [NPT] NPT, Plumbing Thread Nominal: [1/4] 1/4, Fluid Characteristics: Noncorrosive / Incombustible, Pressure Resistance(MPa): 1.5, Operating Humidity

Pressure Range: 0 to 1.6 MPa, Piping: NPT 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: -, Lead Wire: -, Bracket: -, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: -, Lead Wire: -, Bracket: -, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 5 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: -, Lead Wire: -, Bracket: -, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 10 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: -, Lead Wire: -, Bracket: -, Operation Manual/Calibration Certificate: -