SMC Corporation of America
Elite Part Number Search
Search Results "LEY25DB-50-R11N-X5"

Compatible Motor: Step Motor, Servo/24 VDC, Parallel I/O Type: PNP, I/O Cable Length: 3m, DIN Rail: Screw Mounting, Type: Rod Type, Body Size: 25, Bearing Type: None, Motor Mounting: In-line, Motor Type: Step Motor (Servo/24 VDC), Lead: 16: 5mm; 25: 6mm; 32: 8mm, Stroke: 50mm

Compatible Motor: Step Motor, Servo/24 VDC, Parallel I/O Type: PNP, I/O Cable Length: 3m, DIN Rail: DIN Rail Mounting, Type: Rod Type, Body Size: 25, Bearing Type: None, Motor Mounting: In-line, Motor Type: Step Motor (Servo/24 VDC), Lead: 16: 5mm; 25: 6mm; 32: 8mm, Stroke: 50mm

Protocol: 9 (EtherNet/IPâ„¢), Mounting: 7 (Screw Mounting), Cable Connector: w/o Plug Connector, Actuator: LEY, Type: Rod Type, Body Size: 25, Bearing Type: None, Motor Mounting: D (In-line), Lead: B (16: 5mm; 25: 6mm; 32, 40: 8mm), Stroke: 50mm

Protocol: P (PROFINET), Mounting: 7 (Screw Mounting), Cable Connector: w/o Plug Connector, Actuator: LEY, Type: Rod Type, Body Size: 25, Bearing Type: None, Motor Mounting: D (In-line), Lead: B (16: 5mm; 25: 6mm; 32, 40: 8mm), Stroke: 50mm

Controller Series: LECP1 (Programless Controller), Parallel I/O Type: P (PNP), I/O Cable Length, m: 5, Actuator Series: LEY (Rod Type), Size: 25, Motor Mounting Position: D (In-Line Type), Lead: B (Size 16: 5mm, Size 25: 6mm, Size 32: 8mm), Stroke: 50mm

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Enclosure: IP65

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Enclosure: IP65

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Enclosure: IP65

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Enclosure: IP65

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Enclosure: IP65

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Enclosure: IP65

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Enclosure: IP65,

Fitting Type: H (Connector), Metric Size, Side A: No (Select Inch Size, Side A), Inch Size, Side A: 5F (Tube O.D. 3/4", Tubing Size 1/4"x5/32"), Metric Size, Side B: No (For Types H and L, and Types B or R w/Same Tubing Size), Inch Size, Side B: No (For Types H and L, and Types B or R w/Same Tubing Size), Piping: M (Male)

Fitting Type: H (Connector), Metric Size, Side A: No (Select Inch Size, Side A), Inch Size, Side A: 4E (Tube O.D. 1/2", Tubing Size 1/4"x5/32"), Metric Size, Side B: No (For Types H and L, and Types B or R w/Same Tubing Size), Inch Size, Side B: No (For Types H and L, and Types B or R w/Same Tubing Size), Piping: M (Male)

Part Number Description: KV2 3/8    Product Line: C   Product Line Description: CONNECTORS    Family Code: 747   Family Description: KV2 FITTING    Class Code: KX    Click here to report information errorImage shown may not match exact part number, CONN UNION TEE 3/8 X3/8 X5/32, CONNECTORS, KV2 FITTING

Fitting Type: L (Elbow), Metric Size, Side A: No (Select Inch Size, Side A), Inch Size, Side A: 2A (Tube O.D. 1/8", Tubing Size 1/4"x5/32"), Metric Size, Side B: No (For Types H and L, and Types B or R w/Same Tubing Size), Inch Size, Side B: No (For Types H and L, and Types B or R w/Same Tubing Size), Piping: M (Male)

Fitting Type: R (Run Tee), Metric Size, Side A: No (Select Inch Size, Side A), Inch Size, Side A: 5C (Tube O.D. 3/4", Tubing Size 3/4"x5/8"), Metric Size, Side B: No (For Types H and L, and Types B or R w/Same Tubing Size), Inch Size, Side B: No (For Types H and L, and Types B or R w/Same Tubing Size), Piping: M (Male)

The X5 option, available for the LEY series in sizes 25 and 32, is a dust and drip proof specification equivalent to IP65. The AC servo motors do not require enclosures, but the scraper and lube-retainer configurations are included. Additionally, the body extrusion includes a vent hole and fitting to balance internal pressure so that dust and water are not drawn in. 

The X5 option, available for the LEY series in sizes 25 and 32, is a dust and drip proof specification equivalent to IP65. For DC motor models, the spec is achieved by enclosing the motor in a sealed aluminum cover with a special cable connector, and pairing the rod with a scraper and lub-retainer.

Position and speed can be monitored by the PLC, and except in the case of the single numerical data instruction mode, step data can be edited from the PLC.Applicable to series LEY, LEY-X5;  CC-Link Ver. 1.10 compliant ; 3 types of operation mode available ; Position and speed can be monitored by the PLC ; Step data can be edited from the PLC