Table Accuracy: Basic, Size: 50, Max. Rotation Torque: Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6, Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Standard Cable, Actuator Cable Length: 3, Controller: Step Data Input Type, PNP, I/O Cable Length: 3, Communication Plug Connector: None, Controller Option: DIN Rail Mounting
Series LECP6 controller has two available modes for the setting software and teaching box.? In the easy mode, the operation can be started by only setting the speed, position, etc.? Using the normal mode allows a further detailed setup.??A few of the?main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator
Series LECP6 controller has two available modes for the setting software and teaching box. In the easy mode, the operation can be started by only setting the speed, position, etc. Using the normal mode allows a further detailed setup. A few of the main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CONTROLLER, STEP PNP, ACTUATOR, ELECTRIC ACTUATOR, MC, 40MM LE ELECTRIC ACTUATOR, 0.55115 lb
Designed to be compact and function in areas where height and space is limited, SMCs new LEL low-profile electric actuator acheives a 50% reduction in height (when compared to the LEFB) by side mounting the motor.? Suitable for handling operations, this guide rod slider is available with sliding bearings or ball bushing bearings.? Both types offer positioning repeatability of ?0.1mm, and
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32 , Belt drive , Applicable stroke range: 300, 500, 600, 700, 800, 900, 1000, 1200, 1500, 1800, 2000 , 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or
Actuation typeGuide typeOperating temp. rangeOperating humidity range [%RH]Motor sizeMotor output [W]Motor typeEncoderRated voltage [V]Power consumption [W] Note 7)Standby power consumption when operating [W] Note 8)Momentary max. power consumption [W] Note 9)Controller weightType Note 10)Holding force lbf [N]Power consumption [W] Note 11)HorizontalVerticalLEY25A30, 50, 100, 150, 200250, 300
Size: 40, Motor Mounting Position: D (In-line Type), Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 200mm, Motor Option: B (w/Lock), Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: C (20m), Controller Type - LEC, JXC: CP1 (JXCP1, PROFINET), I/O Cable
Controller Series: Programless Controller, Parallel I/O Type: NPN, I/O Cable Length, m: 1.5, Actuator Series: Rod Type, Size: 40, Motor Mounting Position: In-Line Type, Lead: Size 16: 2.5mm, Size 25: 3mm, Size 32: 4mm, Stroke: 50mm
Controller Series: Programless Controller, Parallel I/O Type: PNP, I/O Cable Length, m: 1.5, Actuator Series: Rod Type, Size: 40, Motor Mounting Position: In-Line Type, Lead: Size 16: 2.5mm, Size 25: 3mm, Size 32: 4mm, Stroke: 50mm
Controller Series: Programless Controller, Parallel I/O Type: NPN, I/O Cable Length, m: 5, Actuator Series: Rod Type, Size: 40, Motor Mounting Position: In-Line Type, Lead: Size 16: 2.5mm, Size 25: 3mm, Size 32: 4mm, Stroke: 400mm
Controller Series: Programless Controller, Parallel I/O Type: PNP, I/O Cable Length, m: 1.5, Actuator Series: Rod Type, Size: 40, Motor Mounting Position: In-Line Type, Lead: Size 16: 2.5mm, Size 25: 3mm, Size 32: 4mm, Stroke: 100mm
Controller Series: Programless Controller, Parallel I/O Type: PNP, I/O Cable Length, m: 1.5, Actuator Series: Rod Type, Size: 40, Motor Mounting Position: In-Line Type, Lead: Size 16: 2.5mm, Size 25: 3mm, Size 32: 4mm, Stroke: 200mm
Controller Series: Programless Controller, Parallel I/O Type: NPN, I/O Cable Length, m: 1.5, Actuator Series: Rod Type, Size: 40, Motor Mounting Position: In-Line Type, Lead: Size 16: 2.5mm, Size 25: 3mm, Size 32: 4mm, Stroke: 100mm
Controller Series: Programless Controller, Parallel I/O Type: NPN, I/O Cable Length, m: 1.5, Actuator Series: Rod Type, Size: 40, Motor Mounting Position: In-Line Type, Lead: Size 16: 2.5mm, Size 25: 3mm, Size 32: 4mm, Stroke: 150mm
Series LECP6 controller has two available modes for the setting software and teaching box. In the easy mode, the operation can be started by only setting the speed, position, etc. Using the normal mode allows a further detailed setup. A few of the main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator
Series LECP6 controller has two available modes for the setting software and teaching box. In the easy mode, the operation can be started by only setting the speed, position, etc. Using the normal mode allows a further detailed setup. A few of the main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator
Series LECP6 controller has two available modes for the setting software and teaching box. In the easy mode, the operation can be started by only setting the speed, position, etc. Using the normal mode allows a further detailed setup. A few of the main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator
Series LECP6 controller has two available modes for the setting software and teaching box. In the easy mode, the operation can be started by only setting the speed, position, etc. Using the normal mode allows a further detailed setup. A few of the main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting