Symbol: 09R3 (N.C., Port 1 IN, Port 2 OUT), Function: Y1 (Power-saving Circuit), Voltage: 5 (24VDC), Wetted Part Material: B (Plate: PEEK; Diaphragm: FKM), Reverse Mounting Prevention Pin: P (Reverse Mounting Prevention Pin), Lead Wire Length: 3 (300mm), CE Compliant: Q (CE Compliant)

Symbol: 09R3 (N.C., Port 1 IN, Port 2 OUT), Function: Y1 (Power-saving Circuit), Voltage: 5 (24VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Reverse Mounting Prevention Pin: P (Reverse Mounting Prevention Pin), Lead Wire Length: 3 (300mm), CE Compliant: Q (CE Compliant)

Symbol: 09R3 (N.C., Port 1 IN, Port 2 OUT), Function: Y1 (Power-saving Circuit), Voltage: 6 (12VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Reverse Mounting Prevention Pin: P (Reverse Mounting Prevention Pin), Lead Wire Length: 3 (300mm), CE Compliant: Q (CE Compliant)

Symbol: 09R3 (N.C., Port 1 IN, Port 2 OUT), Function: Y1 (Power-saving Circuit), Voltage: 6 (12VDC), Wetted Part Material: B (Plate: PEEK; Diaphragm: FKM), Reverse Mounting Prevention Pin: P (Reverse Mounting Prevention Pin), Lead Wire Length: 3 (300mm), CE Compliant: Q (CE Compliant)

Symbol: 09R3 (N.C., Port 1 IN, Port 2 OUT), Function: Y1 (Power-saving Circuit), Voltage: 6 (12VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Reverse Mounting Prevention Pin: P (Reverse Mounting Prevention Pin), Lead Wire Length: 3 (300mm), CE Compliant: Q (CE Compliant)

Symbol: N.C., Port 1 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 12VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Reverse Mounting Prevention Pin: None, Lead Wire Length: 300mm, CE Compliant: CE Compliant

Symbol: N.C., Port 1 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 12VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Reverse Mounting Prevention Pin: None, Lead Wire Length: 300mm, CE Compliant: CE Compliant

Symbol: N.C., Port 1 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 12VDC, Wetted Part Material: Plate: PEEK; Diaphragm: Kalrez®, Reverse Mounting Prevention Pin: None, Lead Wire Length: 300mm, CE Compliant: CE Compliant

Symbol: N.C., Port 1 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 24VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Reverse Mounting Prevention Pin: Reverse Mounting Prevention Pin, Lead Wire Length: 300mm, CE Compliant: CE Compliant

Symbol: N.C., Port 1 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 24VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Reverse Mounting Prevention Pin: Reverse Mounting Prevention Pin, Lead Wire Length: 300mm, CE Compliant: CE Compliant

Symbol: N.C., Port 1 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 24VDC, Wetted Part Material: Plate: PEEK; Diaphragm: Kalrez®, Reverse Mounting Prevention Pin: Reverse Mounting Prevention Pin, Lead Wire Length: 300mm, CE Compliant: CE Compliant

Symbol: N.C., Port 1 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 12VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Reverse Mounting Prevention Pin: Reverse Mounting Prevention Pin, Lead Wire Length: 300mm, CE Compliant: CE Compliant

Symbol: N.C., Port 1 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 12VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Reverse Mounting Prevention Pin: Reverse Mounting Prevention Pin, Lead Wire Length: 300mm, CE Compliant: CE Compliant

Symbol: N.C., Port 1 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 12VDC, Wetted Part Material: Plate: PEEK; Diaphragm: Kalrez®, Reverse Mounting Prevention Pin: Reverse Mounting Prevention Pin, Lead Wire Length: 300mm, CE Compliant: CE Compliant

Please contact us for the latest version.sales@ocaire.com, VALVE, VALVE, LVM CHEMICAL VALVE, 2 PORT, 2A, LVM BODY PORT, NO SIZE RATING, .05924 lb, ModelValve constructionValve typeNumber of portsFluid Note 1)Operating pressure rangeOrifice diameterResponse timeLeakageProof pressure Note 2)Ambient temperatureFluid temperatureVolume of valve chamber Note 3)Mounting orientation Note

Series LVM is a compact, direct acting, 2/3 port solenoid valve for chemicals. The unique construction reduces residual liquid to a minimum. Superior resistance to chemicals requires less maintenance.

Symbol: Body Ported, 2 Port, N.C., M5 Thread, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size: w/o Sub-plate, Option: Bracket + Manual Override, Lead Wire Length: -

Symbol: Body Ported, 3 Port, Universal, Tubing Type, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Bracket + Manual Override, Lead Wire Length: -, CE Compliant: -

Compatible Fluid: Air / Water / Chemical, Operating Environment: Standard, Type: Electromagnetic Type, Switching Type: Normally Closed, Body Material: Resin, Connection Type: Others, Operating Temperature Range(°C): 0~50, Driving Type: Linear Motion Type, Orifice Diameter(Ø): 1.1, Insulation Class: B, Pipe opening type (details): Base Mounted Type, Voltage: 24 V DC, Power Consumption(W):

Compatible Fluid: Air / Water / Chemical, Operating Environment: Standard, Type: Electromagnetic Type, Switching Type: Universal, Body Material: Resin, Connection Type: Others, Operating Temperature Range(°C): 0~50, Driving Type: Linear Motion Type, Orifice Diameter(Ø): 1.1, Insulation Class: B, Pipe opening type (details): Base Mounted Type, Voltage: 24 V DC, Power Consumption(W): 2, Lead