500, 600, 700, 800 Oversized rod cylinder XB5 125 1500 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Heat resistant cylinder (150C) XB6 Intermediate strokes are available.
and replacement of emitters 5 q Removal of nozzle w Removal of emitter q Turn counterclockwise. w Pull forward to remove. q Turn counterclockwise. w Pull forward to remove. 6 Bypass nozzle (Option) OSHA1910.242b compliant Even if the nozzle is obstructed, the main orifice pressure cannot exceed 30 psi (210 kPa). * Supply pressure: 0.5 MPa or less 180 Gun Type Ionizer IZG10 Series Application
MC NFB Servomotor HC-PQ Power supply Single phase 200VAC (Type A) or Single phase 100VAC (Type A1) C P U L1 U V V W Servo amp SM L2 W MR-CA E or MR-CA1 The length of the cable between the controller and servo amp is 2m or less.
with lock [kg] LEKFS40V8 Series Stroke [mm] 150 200 250 300 350 400 450 500 600 700 800 900 1000 1100 1200 Motor type 6.0 6.3 6.6 6.9 7.2 7.5 7.8 8.1 8.7 9.3 9.9 10.5 11.1 11.7 12.3 0.7 Additional weight with lock [kg] -8- 2.2 How to Order AC servo motor LECS* series L E K F S 32 R S3 B 200 N S 2 A2 Motor type Size Motor mounting Symbol Type Output(W) Size Compatible driver Nil In-line 25
MTS Air pressure supplied from A operates on both surfaces q and w. (Extension) MY q w A B Piping is concentrated in the head cover. CY MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CX Air pressure supplied from B operates on surfaces e.
Bowl material Drain discharge mechanism Drain port Other Model 20 30 40 50 60 AFF/AM/AMD AMK Modular Connection Example With drain cock C2SF-D AM54P-120AS AM64P-120AS With bowl guard C2SF-C-D C3SF-D C4SF-D Drain cock with barb fitting With bowl guard C3SF-W-D C4SF-W-D AM54P-120AS-W AM64P-120AS-W Manual With drain guide (without valve function) C2SFm-J-D AM54P-m120AS-J AM64P-m120AS-J
AC (1) Yes (W/o indicator light) Yes (W/o indicator light) (3) Nil Standard (1) (1) High pressure (Metal seal only) Note 1) Applicable to VQZ2000 and 3000.
Without lead wire Nil 6 10 15 20 25 30 300 600 1000 1500 2000 2500 3000 Blue (2) Red (2) Gray (2) 1 2 3 For 100 VAC For 200 VAC Another VAC Molded coil With indicator light (AC) Concave groove Pin Cover 4 Red: +, Black: For DC Varistor Neon bulb Lever DC indicator Note) When ordering a valve with a lead wire of 600 mm or longer, be sure to indicate the model number of the valve without connector
Power saving circuit is not : SY100-30-A Without lead wire available in the case of W type.
CA1 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 CS1 80 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 100 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Accessories Order Made Made to Order Double clevis Single clevis Rear flange Front flange Basic Center trunnion Foot Mounting Refer to p.5.4
Refer to gauge guide (P.94,95). t t r Sample Order Number Port w w w q q q t AK1002S e q 4 4 4 4 4 w 4 4 4 4 4 r 2P 3P 4P 4PL 5PC 2P 3P 4P Pressure gauge unit 2) MPA MPA MPA MPA V3 V3 V3 V3 t r t 1 Unit psig/bar MPa Code 0 0 No code MPA 1 w w q q 2) Pressure gauge unit MPa or psig/bar selectable.
Allowable load mass on guides/Allowable moment w 3 Table 4.
Item XL -25 XL -40 XL -50 XL -63 XL -80 Rated heater voltage 90 to 125VAC 200/10 200/20 400/40 400/60 600/100 Heater power W (nominal value) In-rush/Normal (Option symbol) H1 80C (176F) 200/40 200/60 400/100 600/150 H2 100C (212F) 200/30 400/70 400/80 600/130 800/180 H3 120C (248F) Note) In-rush current will flow to the heater for approximately 30 seconds and will then subside.
or less 20 VA or less 10 W or less 20 VA or less 10 W or less 20 VA or less 10 W or less Power consumption Between case and AC line: 1500 VAC for 1 min.
or less 20 VA or less 10 W or less 20 VA or less 10 W or less 20 VA or less 10 W or less Power consumption Between case and AC line: 1500 VAC for 1 min.
fluid temperature[] 60Hz 50Hz Fig. 9-5 Heating capacity(HRS050-A-20-(BJM)) 9.5.2 HRS050-W-20-(BJM) 2000 2000 Ambient Ambient temperature temperature 5 20 25 32 40 1500 1500 5 20 25 32 40 Heating capacity [W] Heating capacity [W] 1000 1000 500 500 0 0 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 Circulating fluid temperature[] Circulating fluid temperature[] 50Hz 60Hz Fig. 9-6 Heating capacity
Power consumption (W): For AC, W = VAcos. For DC, W = VA. Note) cos shows power factor. cos 0.9 3. Symbol When the valve is closed, flow is blocked from port 1 to port 2. However, if the pressure in port 2 is higher than port 1, the valve will not be able to block the fluid and it will flow from port 2 to port 1. 2.
, 125, 160, 200, 250, 320, 400, 500, 600 63 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 80 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 100 Intermediate strokes are available.
, 125, 160, 200, 250, 320, 400, 500, 600 63 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 80 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 100 Intermediate strokes are available.
d80 . %100 0 . 3 ~ "32 0. 1 8 "SO 0.58 50 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, SOD, 600 Allowable rotating torque "40 0.33 " 100 0.69 . ft Ibs max . . : 63 25,50,75,1 00,125,1 50 ,175,200, %50,.063 0.47 250, 300.350,400,450,500, 600 sr 25, so, 75. 100, 125. 150, 175 ,200,250, 300,350, 400, 450, 500, 600, 700 Nole 1) AbsOfbabte kinshc energy by cushIOn mechanIsm IS