Counterbore depth 12.5 7 8 49.5 + Stroke 38 71.5 95.5 + Stroke Retraction locking LOCK 28 Pc PL Port thread type Rc NPT G 1/8 1/4 M5 x 0.8 Dust cover (Manual unlocking unit) PL unlocking port Unlocks when pressurized Rod end male threads M18 x 1.5 11 26 Rod end nut 28.5 33.5 9 Compact Cylinder with Air Cushion and Lock Series RLQ Dimensions/50 (Emergency Stop) Foot type/RLQL50 18 38 49.5
Grease pack part number: GR-S010 (10 g), GR-S-020 (20 g) 59 Series C96 Dimensions Bore size Stroke Basic: C96S(D)B SW PL 2 x EE PL KK WA B D B R E WB Cushion valve 8 x RT VD L9 BG L2 L12 A WH G H G L8 + Stroke VA ZZ + Stroke R E With rod boot e d f l h h + L8 + VA + Stroke Stroke range (mm) A B d11 D EE PL RT L12 KK SW G BG L8 VD VA WA WB WH ZZ E R Bore size (mm) Without rod boot With rod
Counterbore depth 12.5 7 8 49.5 + Stroke 38 71.5 95.5 + Stroke Retraction locking LOCK 28 PL Pc Thread type Rc NPT G 1/8 1/4 M5 x 0.8 Dust cover (Manual unlocking unit) PL unlocking port Unlocks when pressurized Rod end male thread M18 x 1.5 11 26 Rod end nut 28.5 33.5 9-12-14 15 Series RLQ Compact Cylinder with Air Cushion and Lock Dimensions: 50 (Emergency stop) Foot style: RLQL50 18 38
Dimension changes for Options Oversized rod (XB5 Option) Rotated Ports (XC3 Option) Port standard location Head end KK MM B Rod end Cushion location standard WF ZJ + Stroke A How to Order: -XC3 Port Cushion Standard Part Number Location.
0 0.033 0 0.039 1/8 1/8 1/8 1/8 8 20 20 8 80 18 55 13 26 5 57.5 73.5 15.5 3.5 38 6 13 8 28 8 4 41 4 Up to 300 10 25 26 8 90 19.5 22 64.5 17 32 6 69 83.5 4 45 9 13 8 33.5 9 7 45 7 Up to 300 12 32 26 19.5 8 90 22 64.5 17 32 6 69 83.5 4 45 9 13 8 37.5 9 7 45 7 Up to 300 14 40 21 32 11 100.5 24 70 22 41 8 76 90.5 4 52 11 16 10 46.5 8 8 50 7 Up to 300 NN Boss-cut ZZ K Bore size (mm) N NA PH PL
0 0.033 0 0.039 1/8 1/8 1/8 1/8 8 20 20 8 80 18 55 13 26 5 57.5 73.5 15.5 3.5 38 6 13 8 28 8 4 41 4 Up to 300 10 25 26 8 90 19.5 22 64.5 17 32 6 69 83.5 4 45 9 13 8 33.5 9 7 45 7 Up to 300 12 32 26 19.5 8 90 22 64.5 17 32 6 69 83.5 4 45 9 13 8 37.5 9 7 45 7 Up to 300 14 40 21 32 11 100.5 24 70 22 41 8 76 90.5 4 52 11 16 10 46.5 8 8 50 7 Up to 300 NN Boss-cut ZZ K Bore size (mm) N NA PH PL
Category EN ISO 13849-1 Cat. 2, Cat. 4 PL Performance level EN ISO 13849-1 PL d, PL e Table 1-2 General Abbreviations Abbreviation Meaning PELV Protective extra-low voltage according to EN 61140 SELV Separated extra-low voltage according to EN 61140 Explanations of terms and abbreviations used in the context of PROFIsafe: see Appendix A: Glossary for PROFIsafe. 16 No.EX##-OMY0011-A 2.
Use the switch that complies with the requirement of ISO/EN ISO 13849-1 category 3 PL d as an emergency stop switch. This connection example complies with the requirement of ISO/EN ISO 13849-1 category 3 PL d.
STO 13.3.4 3.2.2 MC-YOBPC-YOB STOISO/EN ISO 13849-13 PL d ISO/EN ISO 13849-1 3 PL d(X) (Y) 24 V S1 iQ EMG (Q173DSXY) CPU MC I/O B20 (MC) KM1 Q17_DSCPU MC-X00 EM2 A1 0 V CN8 B09 (MC) MC-Y0B S T O1 B1 DC 24 (MC) B19 T OFCOM V MC-X01 T OFB1 PLC I/O (PC) B19 PC-X01 T OFB2 iQ CPU (PC) B1 DC 24 V S T OCOM B09 PC-Y0B S T O2 B20 (PC) PC-X00 CN3 A1 KM1 EM2 0 V 0 V M S1STO (STO ) KM1 EMG 13
'I. 78 2S 52 14 / 113 21 30 72 23 17 M1 2X l .75 _boot With boot PW S W H 12 ... 1 h f zz j IBore olze k U M MM MM (mm) XIUS N P PG PH PL 40 6 71 11 M1 4Xl .5 7/' 6 20 27 'I, 42 11 20 45 153 8 51 215 43 11 .2 59 223 168 0 I50 58 237 52 11.2 66 245 50 7 80 11 M18Xl .5 30 0/, 46 10 21 V.
The transient from subsonic to sonic flow is reached, whn the pressurc ratio of the absolute input and outsut pressures is lss or equal to 1.896: Sonic tlow: pl + 1,013 <1.896 . (pA +1.013) Subsonlc flow: pl + 1.013 > 1.896 . (pa +1.013) The Volume flow Olor subsonic flow eouals: Q = x2.2 .5.{(pa + 1.013) ' (pl -pa) (vmin) and for sonic flow: O= 11,1 .S.
Pl ease use i t put t i ng i t on t he connect or f or t he com m uni cat i on. Pi n assi gn of I TV si de connect or I t em Pi n assi g W i re co l o r (N o te 1) +24[ V] Brow n 4 3 F. G . W hi t e Pow er suppl y connect or G N D Bl ue 2 N . C. Com m uni cat i on connect or Pl ease i nst al l t he bus adapt orEX9ACY00M J of t he at t achm ent .
The transient from subsonic to sonic flow is reached, whn the pressurc ratio of the absolute input and outsut pressures is lss or equal to 1.896: Sonic tlow: pl + 1,013 <1.896 . (pA +1.013) Subsonlc flow: pl + 1.013 > 1.896 . (pa +1.013) The Volume flow Olor subsonic flow eouals: Q = x2.2 .5.{(pa + 1.013) ' (pl -pa) (vmin) and for sonic flow: O= 11,1 .S.
ul .75 L98 2.257.50 [/A 1.503.75NlA r{/A Pl 2t 50tt t, -2, .3 t7.9i18.62 2.48{ln 2Y2'12 UN .75 2.38 2.38 9.50 N/A t.50 4.15 N/A N/A All dimensions in nches. Sh*ck Absorbens Non-Adjustable Hydraulic Series qigfE. I PM Series Metric Pl\415251\4 "+ PM2150M PM120M -.+ PM225M *Note: A1 and E1 apply to urethane striker cap accessory.
Grease pack part number: GR-S-010 (10 g), GR-S-020 (20 g) 27 Piston B Aluminum alloy 1 32 to 63 Aluminum die-cast 1 80, 100 28 Cushion ring Aluminum alloy 1 Anodized 29 Cushion ring B Aluminum alloy 1 Anodized 30 Cushion valve Resin 2 31 Cushion seal holder Aluminum alloy 1 Anodized 12 CP96N Series Dimensions (Single Rod) GC GA GB GD2 PL EE Rod side cylinder port EE Head side cylinder port
Oversized rod -XB5 Special port positions -XC3 1 3 The strength of the cylinder is increased by increasing the diameter of the piston rod. This cylinder is used when the stroke is long, and there is a danger of the piston rod bending or buckling, etc. (Please contact SMC in case a lateral load will be applied.)
Heavy duty rod cylinder XB5 4 The strength of the cylinder is increased by increasing the diameter of the piston rod. This cylinder is used when the stroke is long, and there is a danger of the piston rod bending or buckling, etc.
Oversized Rod Cylinder -XB5 Special Port Position -XC3 1 4 A cylinder that has been made stronger through the use of a piston rod with a larger diameter. It is used for long stroke applications that pose the risk of bending or buckling of the piston rod. (Consult with SMC if a lateral load must be applied to it.)
Refer to page 66 for part numbers. 43 47 Non-standard Motor Series LTF8 Motor Output Ground Ball Screw 200W 15mm/20mm lead Horizontal Mount How to Order Motor/switch entry direction Stroke F LTF8 PL 1 G X10 Left entry Power supply voltage Motor specification Switch specifications Right entry Matsushita Electric Industrial Co., Ltd.
Pl ease never w i re f or nei t her pi n 2 nor pi n 4 w hen you use ot her 4w i re cabl es. An i nt ernal subst rat e m i ght be dam aged. The com m uni cat i ons cabl e recom m ends t he use of our com pany PCA1557633. Sel ect a D C pow er suppl y w i t h adequat e capaci t y w i t h l ow ri ppl e. Ex. : Cl ass 2 vol t age source. U L1310 com pl i ant .