Delivery Pressure: P [50 to 6000 psig (0.34 to 41.4 MPa)], Relieving: 1 (Self-relieving, Standard), Material: B (Brass), Ports: 4P (4 Ports), Connections: 4 (NPT 1/4 Inch), Gauge Port, Inlet: 60 [6000 psig (41 MPa)], Gauge Port, Outlet: 20 [2000 psig (14 MPa)], Pressure Gauge Unit: psig/bar (or None in Case of no Gauge), Main Valve Seat Material: Vespel®, Standard, O-ring Material: VitonÂ
Delivery Pressure: P [50 to 6000 psig (0.34 to 41.4 MPa)], Relieving: 1 (Self-relieving, Standard), Material: B (Brass), Ports: 4P (4 Ports), Connections: 4 (NPT 1/4 Inch), Gauge Port, Inlet: 60 [6000 psig (41 MPa)], Gauge Port, Outlet: 20 [2000 psig (14 MPa)], Pressure Gauge Unit: psig/bar (or None in Case of no Gauge), Main Valve Seat Material: Vespel®, Standard, O-ring Material: VitonÂ
Delivery Pressure: P [50 to 6000 psig (0.34 to 41.4 MPa)], Relieving: 1 (Self-relieving, Standard), Material: C (300 SS Series), Ports: 4P (4 Ports), Connections: 4 (NPT 1/4 Inch), Gauge Port, Inlet: 60 [6000 psig (41 MPa)], Gauge Port, Outlet: 20 [2000 psig (14 MPa)], Pressure Gauge Unit: psig/bar (or None in Case of no Gauge), Main Valve Seat Material: Vespel®, Standard, O-ring Material
Delivery Pressure: P [50 to 6000 psig (0.34 to 41.4 MPa)], Relieving: 1 (Self-relieving, Standard), Material: B (Brass), Ports: 4P (4 Ports), Connections: 4 (NPT 1/4 Inch), Gauge Port, Inlet: Q [10000 psig (70 MPa)], Gauge Port, Outlet: 60 [6000 psig (41 MPa)], Pressure Gauge Unit: psig/bar (or None in Case of no Gauge), Main Valve Seat Material: Vespel®, Standard, O-ring Material: VitonÂ
, 2" , NPN or PNP open collector, 1 output + analog , Flow rate (l/min): 150~3000, 300~6000, 600~12000, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IF/PFA FLOW SWITCH, JB, IF/PFA 1 1/2 INCH NPT VERSION, 3.99153 lb, ModelMeasured fluidDetection typeRated flow range Note 1)Minimum set unit Note 1)Note 2)Display unitsOperating pressure rangeProof pressurePressure lossAccumulated
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Weight (kg) 0.05 0.075 AC4000/5000/5500/6000 AR4000/5000/6000 AW4000 Applicable model C Part no.: 1305104-1A C1 Attachment: With cover ring assembly Part no.: 1305104-3A Note 1) Indicates the condition at the lower pressure limit.
PAT. 17-5-172 33 Flow Switch Series PF, IF For Air Digital Flow Switch/Series PFA Display integral type Output specification Port size (Rc, NPT, G) Flow rate range (l/min) Separate type Display Sensor Switch output Analog output Accumulated pulse output PFA710 750 711 721 751 703H 706H 712H PFA510 550 511 521 551 1 to 10 5 to 50 10 to 100 20 to 200 50 to 500 150 to 3000 300 to 6000 6000 to
Flow capacity (l/min (ANR)) Oil mist concentration at outlet side 300 750 1500 2200 3500 Filtration (m) Port size Rc Model AM150 AM250 AM350 AM450 AM550 1 8 1 4 3 8 1 4 3 8 1 2 3 8 1 2 3 4 Max. 1.0 mg/m3 (ANR) ( 0.8 ppm) , , , , , , , , , 1 1 0.3 1 2 3 4 3 4 1, 1 2 1 , 2 AM650 6000 AM850 12000 1 2 Can produce with auto drain type, drain piping type.
70C (Application of rated voltage) Temperature rise Power consumption DC Holding Inrush 5.6VA(50Hz), 5.0VA(60Hz) 12VA(50Hz), 10.5VA(60Hz) 3.4VA(50Hz), 2.3VA(60Hz) 7.5VA(50Hz), 6VA(60Hz) 1.8W 4.8W Apparent power AC Non-locking push style Others (Option) Manual override Non-locking push style 4.2-5 VNA Flow Characteristics Air How to Read The Graph In the sonic flow region: For a flow of 6000
, 2" , NPN or PNP open collector, 1 output + analog , Flow rate (l/min): 150~3000, 300~6000, 600~12000, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IF/PFA FLOW SWITCH, JB, IF/PFA 1 1/2 INCH NPT VERSION, 4.23287 lb, ModelMeasured fluidDetection typeRated flow range Note 1)Minimum set unit Note 1)Note 2)Display unitsOperating pressure rangeProof pressurePressure lossAccumulated
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Magnetically coupled cylinders save space and have a wide range of applications. The NCY series can be used in many diverse environments, because there is no external leakage. The use of a linear guide makes loading and moments, directly on the cylinder possible. T-Slots on the mounting surfaces provides mounting freedom, and a variety of guides can be used to achieve the necessary accuracy
Magnet: D (Built-in), Bore Size: 10 (3/8 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 0800 (8 Inch), Adjuster: BC (Cap Type Shock Absorber (2 pcs.)), Auto Switch: A73L--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, 3M
Magnet: D (Built-in), Bore Size: 10 (3/8 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 1000 (10 Inch), Adjuster: Adjuster Bolt, Auto Switch: A73L--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, 3M
Magnet: D (Built-in), Bore Size: 10 (3/8 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 0500 (5 Inch), Adjuster: B (Shock Absorber (2 pcs.)), Auto Switch: A73L--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, 3M
Magnet: D (Built-in), Bore Size: 10 (3/8 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 0400 (4 Inch), Adjuster: Adjuster Bolt, Auto Switch: A73L--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, 3M, Number: 3 pcs.
Magnet: D (Built-in), Bore Size: 10 (3/8 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 0300 (3 Inch), Adjuster: B (Shock Absorber (2 pcs.)), Auto Switch: A73L--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, 3M