mm +1.8 0 +1.4 0 +1.8 0 Stroke tolerance Up to 1000 mm, Up to 1200 mm Up to 1500 mm CM2 JIS class 2 Thread tolerance Rubber bumper/Air cushion Cushion C85 Basic, Axial foot, Front flange, Rear flange, Front trunnion, Rear trunnion, Clevis (Used for changing the port location by 90 degrees.)
Display the error code on LCD. 3 1/2 digits (5 mm-size numerals) Overcurrent, Overpressure, Data error Pressure during 0 clear 0 to 60C (No dewing) 1000 Vp-p, Pulse width 1 s, Rise time 1 ns Between external terminals and housing 1000 VAC, 50/60 Hz for 1 min.
) PE07 100 1000 600 300 1200 800 400 1500 1000 500 Home position return position data (m) PE08 0 -2000 (<1000 stroke)/-200 (>1000 stroke) Stopper type home position return stopper time (msec) PE10 100 200 Stopper type home position return torque limit value (%) PE11 15 30 Regenerative option PA02 000 000 (Non)/002 (LEC-MR-RB-032) Rotation direction selection *4 PA14 0 1 (+Counter motors side
1500 100 200 300 400500 1000 1500 100 200 300 400500 1000 1500 Piston speed mm/s Piston speed mm/s Piston speed mm/s Load Weight/MY2C MY2C/m1 MY2C/m2 MY2C/m3 60 60 60 50 50 50 30 30 30 20 20 20 Load weight Nm Load weight Nm Load weight Nm MY2C40 MY2C40 MY2C40 10 10 10 MY2C25 MY2C25 MY2C25 5 5 5 4 4 4 MY2C16 MY2C16 3 3 3 MY2C16 2 2 2 1 1 1 100 200 300 400500 1000 1500 100 200 300 400500 1000
80 33 (330) 1500 40 40 to 1000 80 47 (470) 1500 50 50 to 1200 80 84 (840) 1500 63 63 to 1200 80 127 (1270) 1500 80 80 to 1400 80 Symbol 196 (1960) 1500 100 100 to 1500 80 Note 1) When the standard stroke is exceeded, it is outside the guaranteed range.
Minimum Bending Radius (mm) 1/8 9.4 5/32 12.7 3/16 19.1 1/4 25.4 5/16 31.8 3/8 38.1 1/2 50.8 5/8 63.5 3/4 76.2 Minimum Burst Pressure (psi) at 24C (75F) 1000 1200 1200 1200 1000 1000 950 900 800 Material Nylon 12 (Polyamide) *Note: Recommended operating fluid and temperature range provides best performance and longest life.
20 200, 300, 400, 500, 600, 800 25 1200 25 2 axes 200, 300, 400, 500, 600, 800, 1000 1500 32 Note 1) Strokes exceeding the standard strokes are available as a special order.
50 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 6000 63 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 Made to Order Specifications (For details, refer to page 10-21-1.)
50 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 6000 63 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 Made to Order Specifications (For details, refer to page 10-21-1.)
, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 2 2 1 100 200 300 400 500 1000 1 100 300 400 500 1000 200 Maximum speed: V (mm/s) Maximum speed: V (mm/s) Graph (6) Graph (3) 0.4 MPa P < 0.5 MPa 0.4 MPa P < 0.5 MPa 1000 1000 100 80 500 400 300 500 400 300 63 63 63 100 80 200 200 50 40 50 50 100 100 Load weight: m (kg) Load weight:
However under Japanese regulation, only MPa is available in Japan. 40 Specifications 1) Source pressure above 1000 psig (6.9 MPa) decreases maximum delivery pressure to less than 150 psig (1 MPa) due to supply pressure effect.
Up to 600 601 to 1000 Up to 750 751 to 1000 Up to 750 751 to 1000 Long stroke The minimum stroke of the one with rod boot is 20 mm or more.
Up to 600 601 to 1000 Up to 750 751 to 1000 Up to 750 751 to 1000 30 35 35 40 40 27 32 32 37 37 60 70 85 102 116 22 27 27 32 41 44 52 64 78 92 16 20 20 25 30 32 40 40 52 52 10 10 10 14 14 6 7 7 11 11 9 9 11.5 13.5 13.5 40 45 50 65 75 86 83 83 84 85 138 144 166 204 212 3.2 3.2 3.2 4.5 6 42 50 59 76 92 70 80 93 116 133 M8 x 1.25 M8 x 1.25 M10 x 1.25 M12 x 1.75 M12 x 1.75 8 11 11 13 16 Bore
Mitsubishi Electric Corporation Yaskawa Electric Corporation LJ1H202NA 100W to 500 LJ1H303SE 200W to 500 to 500 to 500 LJ1H202PC 100W to 1000 to 740 to 930 to 600 to 500 LJ1H202NC 100W to 740 to 930 to 600 to 500 to 1000 LJ1H303PD 200W to 1000 to 1000 to 1000 to 700 to 500 LJ1H303ND 200W to 1000 to 1000 to 700 to 500 to 1000 LJ1H102PH-K 100W to 400 LJ1H102NH-K 100W to 400 LJ1H202PF-K 100W
Mitsubishi Electric Corporation Yaskawa Electric Corporation LJ1H202NA 100W to 500 LJ1H303SE 200W to 500 to 500 to 500 LJ1H202PC 100W to 1000 to 740 to 930 to 600 to 500 LJ1H202NC 100W to 740 to 930 to 600 to 500 to 1000 LJ1H303PD 200W to 1000 to 1000 to 1000 to 700 to 500 LJ1H303ND 200W to 1000 to 1000 to 700 to 500 to 1000 LJ1H102PH-K 100W to 400 LJ1H102NH-K 100W to 400 LJ1H202PF-K 100W
LJ1H202NC 14 56 to 740 to 930 to 600 to 500 to 1000 LJ1H303PD to 1000 to 1000 to 700 to 500 18 60 to 1000 126 114 108 LJ1H303ND 20 62 to 1000 to 1000 to 700 to 500 to 1000 LJ1H102PH-K 24 66 to 400 104 110 LJ1H102NH-K 28 70 to 400 LJ1H202PA-K 34 76 to 500 106 112 LJ1H202NA-K 38 80 to 500 LJ1H102PB-K 26 68 to 600 145 104 110 LJ1H102NB-K 30 72 to 600 LJ1H202PF-K 32 74 to 250 106 112 LJ1H202NF-K
VAC for 1 min. between external terminal and case Withstand voltage Resistance 50 M (500 VDC) between external terminal and case Insulation resistance 10 to 500 Hz at whichever is smaller: 1.5 mm amplitude or 98 m/s2 acceleration Vibration resistance 490 m/s2 in X, Y, Z directions 3 times each Impact resistance 1000 Vp-p, Pulse width 1 s, Rise time 1 ns Noise resistance 200 g 240 g Weight
0 200 400 600 800 1000 1200 1400 0 0.2 0.1 0.3 0.4 0.6 0.5 0.8 0.7 0.9 1.0 1000 0 200 400 600 800 Flow rate (L/min (ANR)) Supply pressure P1 (MPa) Relief flow rate (L/min (ANR)) 817 IR1000/2000/3000 Series IR3000 Series The operating conditions or external disturbance may affect each of the characteristics.
0.2 0.2 0.1 0.1 0.196 0 200 400 600 800 1000 1200 1400 0 0.2 0.1 0.3 0.4 0.6 0.5 0.8 0.7 0.9 1.0 0 200 400 600 800 1000 Flow rate l/min (ANR) Relief flow rate l/min (ANR) Supply pressure P1 MPa 6 Series IR1000/2000/3000 Series IR3000 Flow rate characteristics Relief characteristics Pressure characteristics Testing methods conform to JIS B8372.
400 600 800 1000 1200 1400 0 0.2 0.1 0.3 0.4 0.6 0.5 0.8 0.7 0.9 1.0 1000 0 200 400 600 800 Flow rate ( /min (ANR)) Relief flow rate ( /min (ANR)) Supply pressure P1 (MPa) 14-5-11 11 Series IR1000/2000/3000 Series IR3000 Flow Characteristics Relief Characteristics Pressure Characteristics Testing methods conform to JIS B 8372.