BBA4: For D-C7/C8/H7 The stainless steel bolts described above are used when the D-H7BAL type switch is shipped mounted on a cylinder.
BBA3: D-B5/B6/G5 types BBA4: D-C7/C8/H7 types "D-G5BAL" and "D-H7BAL"switches are set on the cylinder with the screws above when shipped. When a switch only is shipped, BBA3 or "BBA4" screws are attached.
D-X Technical Data 357 CG1 Series Auto Switch Proper Mounting Position (Detection at Stroke End) With End Lock (CBG1) (mm) Auto switch model D-G5lW D-K59W D-G59F D-G5 D-K5 D-G5NT D-G5BA D-M9l D-M9lV D-M9lW D-M9lWV D-M9lA D-M9lAV D-H7l D-H7C D-H7lW D-H7BA D-H7NF D-C7 D-C8 D-C73C D-C80C D-A9l D-A9lV D-B5 D-B6 D-B59W Lock position A B A B A B A B A B A B A B Bore size Head end 33 36 29 32 28.5
CE-compliant Valve mounting direction Stations R port Nil Pilot valve is opposite the A port side. 02 2 stations A A M5 x 0.8 Nil R port P R Q CE-compliant : : A A M5 x 0.8 A port M3 x 0.5 P port M5 x 0.8 Pilot valve is on the A port side. 20 S 20 stations P port M5 x 0.8 A port M3 x 0.5 Note) For more than 10 stations, supply air to both sides of P port and exhaust air from both sides of
CE-certified Symbol EX124D-SMJ1-X182 CC-Link (Negative common) V A, B port size (Metric) A, B port size (Inch) P, E port Applicable series P, E port Applicable series A, B port Symbol C4 C6 C8 C8 C10 C12 M A, B port Symbol N3 N7 N9 N9 N11 M One-touch fitting for 4 One-touch fitting for 6 One-touch fitting for 8 One-touch fitting for 8 One-touch fitting for 10 One-touch fitting for 12 A, B
Detaching To detach a socket from a connector, pull out the lead wire while pressing the sockets hook with a stick having a thin tip (approx. 1 mm). If the socket will be used again, first spread the hook outward. 80 A DXT170 Lead wire color Lead wire length Lead wire with socket Lead wire length L mm Symbol Note Symbol Socket only (2 pcs.)
The rotation angle can be adjusted between 90 to 190. n o ti r a a n t o g Rotation starting point 10 10 e End of rotation 160 L L e R B B L g o n B t at a r 160 io 160 n 10 10 n io r at a n t o g Rotation starting point End of rotation A A R e A Lmax Lmax Size 20 30 40 Lmax 24 27 31.5 Size 10 15 20 30 40 Size 20 30 40 Rotation starting point 15 18 24 27 31.5 24 27 31.5 10 End of rotation
P/A as a contact protection box may be necessary.
Setting Position (mm) D-C7 D-C8 D-C73C D-C80C D-G39 D-K39 D-A33, A34 D-A44 D-B5 D-B6 D-H7l D-H7C D-G5NTL D-H7lW D-H7lF D-H7BAL D-B59W Bore size (mm) A B A B A B A B A B A B A B 20 56.0 31.5 50.0 25.5 55.0 30.5 51.5 27.0 53.5 29.0 53.0 28.5 49.5 25.0 25 56.0 31.5 50.0 25.5 55.0 30.5 51.5 27.0 53.5 29.0 53.0 28.5 49.5 25.0 32 59.5 36.5 53.5 30.5 58.0 35.5 55.0 32.5 57.0 34.0 56.5 33.5 53.0
Detaching To detach a socket from a connector, pull out the lead wire while pressing the sockets hook with a stick having a thin tip (approx. 1 mm). If the socket will be used again, first spread the hook outward. Connector assembly with protective cover Connector assembly with protective cover enhances dust protection.
HS Auto switch 36 12 24.5 SMC SMC A 33 B Auto switch 49.5 A B G 1/2 (applicable cable O.D. 6.8 to 11.5) Proper auto switch mounting positions (mm) D-H7 D-H7C D-H7W D-H7BAL D-C7 D-C8 D-C73C D-C80C D-G39 D-K39 D-A33, D-A34 D-A44 D-B5 D-B6 D-G5NTL D-H7F D-B59W Bore size (mm) A A B A A A A B A B B B B B 20 14 10 8.5 12 10.5 14 9 15 13 12 6.5 8.5 12 7 25 14.5 12.5 9.5 9 11 14.5 9.5 12.5 15.5 11.5
HS 8.5 8.5 SMC SMC 16 16 A 36.7 Auto switch A 38.2 B Auto switch Proper auto switch mounting position Auto switch mounting height (mm) (mm) D-B5 D-B6 D-H7 D-H7C D-G5NTL D-H7 W D-H7 F D-H7BAL D-C7 D-C8 D-C73C D-C80C D-B5/B6 D-B59W D-G5NTL Bore size (mm) D-C73C D-C80C D-B59W D-C7,D-C8 D-H7 D-H7C D-H7 W D-H7 F D-H7BAL Bore size (mm) A B A B A B A B A B A HS HS HS B 27 27.5 24.5 20 20 15 17.5
D-H7 D-H7W D-H7NF D-H7BAL D-C7/C8 D-C73C D-C80C D-C73C D-C80C D-B5/B6 D-G59F D-B59W Applicable bore size (mm) A A B A B B A B A B 16 (24) A B Hs Hs Hs 21.5 (29.5) 20.5 (28.5) 15 (22.5) 17.5 (25.5) 19.5 (27.5) 20 4.5 8 6 10 9 3 24.5 27 27.5 21.5 (29.5) 20.5 (28.5) 15 (22.5) 17.5 (25.5) 19.5 (27.5) 16 (24) 25 4.5 8 6 10 9 3 27 29.5 30 22.5 (30.5) 21.5 (29.5) 15.5 (23.5) 18.5 (26.5) 20.5 (28.5
D-H7 D-H7W D-H7NF D-H7BAL D-C7/C8 D-C73C D-C80C D-C73C D-C80C D-B5/B6 D-G59F D-B59W Applicable bore size (mm) A A B A B B A B A B 16 (24) A B Hs Hs Hs 21.5 (29.5) 20.5 (28.5) 15 (22.5) 17.5 (25.5) 19.5 (27.5) 20 4.5 8 6 10 9 3 24.5 27 27.5 21.5 (29.5) 20.5 (28.5) 15 (22.5) 17.5 (25.5) 19.5 (27.5) 16 (24) 25 4.5 8 6 10 9 3 27 29.5 30 22.5 (30.5) 21.5 (29.5) 15.5 (23.5) 18.5 (26.5) 20.5 (28.5
D-A7/A8, D-A7lH/A80H, D-A73C, A80C, D-C7/C8, D-C73C/C80C, D-E7lA, E80A, D-Z7/Z8, D-9/9lA, D-A9/A9lV, and D-A79W type Use an auto switch with a contact protection box in any case listed below. Unless using a contact protection box, the contact life may be shortened. (Due to permanent energizing conditions.)
AD17-A AD27-A AD37-A AD47-A Spacer Y100-A Y200-A Y300-A Y400-A Y500-A Y600-A Spacer with bracket Y100T-A Y200T-A Y300T-A Y400T-A Y500T-A Y600T-A Check valve Note 5) Note 6) AKM2000-01-A (02)-A AKM3000-(01)-A 02-A AKM4000-(02)-A 03-A Pressure switch Note 6) IS10M-20-A IS10M-30-A IS10M-40-A IS10M-50-A IS10M-60-A T-spacer Note 5) Note 6) Y110-M5-A Y210-01-A (02)-A Y310-(01)-A 02-A Y410-(02
For the angle adjusting type, angle adjusting screws are mounted to the left cover. of e g k n e ra y w n a io y Angle adjusting screw Angle adjusting screw at 1 ot 8 0 n R io ct e r di g in st u dj n A o a n ti g c e e l e gl ir d a n d g A j u n s ti ti s n u g j d a d ir e e R R l g c 0 0 n ti ot ot o A 8 8 n 1 1 at at y y io io a a n n w w r r y y a a e e n n k k g g of of e e Angle
SOL. location A B A B A B A B () A B () () 0 1 2 3 4 5 6 Double Double Single SI unit A side B side 3 position A B A B B A B A B A VQC Double Double Single SI unit A side B side 3 position Stations 1 2 3 4 5 SQ The places of asterisk are not used. 3 position uses two stations for wiring.