KK Stroke Bore 51 to 100 101 to 150 102 113 151 to 200 115 126 201 to 300 140 151 301 to 400 165 176 401 to 500 190 201 32 40 90 101 12 14 35 46 30 35 10 12 M10 x 1.5 M12 x 1.75 20 24 Item I Wh Bore Stroke 1 to 50 12.5 12.5 51 to 100 25 25 101 to 150 37.5 37.5 151 to 200 50 50 201 to 300 75 75 301 to 400 100 100 401 to 500 125 125 1 to 50 57 64 51 to 100 70 77 101 to 150 82 89 151 to 200
100 100 100 Wall Y L5 50 50 50 50 0 0.2 0.4 0.6 0.8 1 0 0 0 0 0 0.2 0.4 0.6 0.8 1 0.0 0.4 0.8 1.2 1.6 2.0 Work load [kg] 0.0 0.4 0.8 1.2 1.6 2.0 Work load [kg] Work load [kg] Work load [kg] 200 200 200 200 160 160 160 160 L6 L6 [mm] L6 [mm] L6 [mm] L6 [mm] 120 120 120 120 Z 80 80 80 80 Me m 40 40 40 40 0 0.2 0.4 0.6 0.8 1 0 0 0.2 0.4 0.6 0.8 1 0 0.0 0.4 0.8 1.2 1.6 2.0 0 0.0 0.4 0.8 1.2
The load factor for each direction can be obtained as follows. x = 0/220 = 0 y = 50/210 = 0.24 z = 200/430 = 0.47 5. x + y + z = 0.71 1 LER LEH LEY -X5 1000 1000 1000 11LEFS 800 800 800 11LEJS L3 [mm] L2 [mm] L1 [mm] 600 600 600 25ALz 400 400 400 LEC Lx Ly 200 200 200 LEC S 0 0 0 0 10 20 30 40 50 0 10 20 30 40 50 0 10 20 30 40 50 LEC SS-T Work load [kg] Work load [kg] Work load [kg] LEC
101 200 0.1 0.1 10 25 26 100 101 200 Stroke (mm) Stroke (mm) MGPWL32 to 63, MGPWA32 to 63 (27) L = 50 mm, V = 400 mm/s or less (28) L = 100 mm, V = 400 mm/s or less 100 100 63 63 63 63 63 Load mass m (kg) Load mass m (kg) 63 50 50 50 50 50 10 10 50 40 40 40 40 40 40 32 32 32 32 32 32 1 1 10 50 51 100 101 200 10 50 51 100 101 200 Stroke (mm) Stroke (mm) 510 Compact Guide Cylinder/Wide Type
It is already built-in to the rectifier circuit. 50 60 100 VAC Hz 1 2 200 VAC Hz 50 60 50 60 110 VAC Hz [115 VAC Hz] 3 Electrical entry 50 60 50 60 50 60 DIN terminal D With connector 4 220 VAC Hz [230 VAC Hz] DO Without connector DC specifications of type "D" and "DO" is only available with 12 and 24 V DC. Power saving circuit is not available in the case of "D", "DO" type.
Model selected 10-2-8 8 Series REA Model Selection 2 Caution on Design 1 Selection Method RE A B 25 40 32 500 500 REC 200 300 400 300 200 300 200 Recommended driving force Fn (N) Recommended driving force Fn (N) CX Recommended driving force Fn (N) 100 100 100 CY 50 40 20 30 40 50 20 30 40 50 20 30 MQQ M Usable range
Model selected 10-2-8 8 Series REA Model Selection 2 Caution on Design 1 Selection Method RE A B 25 40 32 500 500 REC 200 300 400 300 200 300 200 Recommended driving force Fn (N) Recommended driving force Fn (N) CX Recommended driving force Fn (N) 100 100 100 CY 50 40 20 30 40 50 20 30 40 50 20 30 MQQ M Courtesy of
Standard Stroke Bore size (mm) Standard stroke (mm) Manufacturable Note) maximum stroke (mm) 6 300 50, 100, 150, 200 10 500 50, 100, 150, 200, 250, 300 50 100, 150, 200, 250, 300, 350, 400, 450 500, 600, 700, 800, 900, 1000 6000 63 Note) Please contact SMC if it is used by exceeding the maximum stroke length.
to Order (For details, refer to pages 2009 to 2152.) 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 40 Symbol Specifications Change of rod end shape 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 50, 63 -XA -XC6 Made of stainless steel 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700 80, 100 Tie-rod, cushion valve and
Bore size (mm) Standard stroke (mm) 2040 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 Data 50, 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 80, 100 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700 Intermediate strokes not listed above are also available.
Model determination 3 Series REA Model Selection 2 Design Parameters 1 Selection Method 25 40 32 500 500 300 400 300 300 Recommended driving force Fn (N) 200 Recommended driving force Fn (N) Recommended driving force Fn (N) 200 200 100 100 100 50 40 20 30 40 50 20 30 40 50 20 30 Usable range Usable range Usable range
/60 Hz 200 VAC, 50/60 Hz 110 to 120 VAC, 50/60 Hz 4 220 VAC, 50/60 Hz 5 6 24 VDC 12 VDC 7 240 VAC, 50/60 Hz 9 Other Option Body Option Pilot type 0 1 Standard Direct manual override R Internal pilot External pilot Nil Option How to Order Pilot Valve Assembly Option SF4 F 1 22 Coil rated voltage 1 100 VAC, 50/60 Hz 2 200 VAC, 50/60 Hz 3110 to 120 VAC, 50/60 Hz 4 220 VAC, 50/60 Hz 5 24 VDC
l 1 to 50 51 to 100 101 to 150 151 to 200 201 to 300 301 to 400 401 to 500 501 to 600 601 to 700 701 to 800 801 to 900 901 to 1000 32 54 36 23 12.5 25 37.5 50 75 100 125 150 175 40 56 41 23 12.5 25 37.5 50 75 100 125 150 175 200 50 64 51 25 12.5 25 37.5 50 75 100 125 150 175 200 225 250 63 64 51 25 12.5 25 37.5 50 75 100 125 150 175 200 225 250 80 68 56 29 12.5 25 37.5 50 75 100 125 150
50mm 63 63mm Standard Stroke Table Bore size (mm) Standard stroke (mm) Maximum Note) available stroke (mm) 300 50, 100, 150, 200 6 500 50, 100, 150, 200, 250, 300 10 50, 100, 150, 200, 250, 300, 350 400, 450, 500 15 1000 20 2000 100, 150, 200, 250, 300, 350, 400, 450 500, 600, 700, 800 25 4000 32 5000 40 100, 150, 200, 250, 300, 350, 400, 450 500, 600, 700, 800, 900, 1000 50 6000 63 Note
400 V type as standard) HRS150 13.0/14.5 3-phase 200 VAC (50 Hz), 3-phase 200 to 230 VAC (60 Hz) With fluid fill port 3-phase 380 to 415 VAC (50 Hz/60 Hz) HRS100 Water-cooled refrigeration 10.0/11.0 HRS150 14.5/16.5 New variations 1 Thermo-chiller Standard Type Series HRS100/150 Circulating Fluid Temperature Controller Circulating uid can be heated without a heater.
Table 7-1 Quality criteria for clean water (tap water) Item Unit Criterion Circulating fluid Facility water pH (at 25 oC) 6.0 to 8.0 6.5 to 8.2 Electric conductance (at 25 oC) [S/cm] 100 to 300 100 to 800 Chloride ion [mg/L] 50 or less 200 or less Sulphate ion [mg/L] 50 or less 200 or less Standard item Acid consumption (at pH 4.8) [mg/L] 50 or less 100 or less Total hardness [mg/L] 70 or
50 60 60 70 70 0 0 40 80 120 160 200 100 200 300 Outlet air flow rate (l/min (ANR)) Outlet air flow rate (l/min (ANR)) IDG100L (Type B products group) Refer to pages 14-19-28 to 29.
The load factor for each direction can be obtained as follows. x = 50/420 = 0.12 y = 100/300 = 0.34 z = 200/1000 = 0.2 5. x + y + z = 0.66 1 LER LEH LEY -X5 1000 500 1000 Lz 11LEFS 800 400 800 11LEJS Ly 600 300 600 L1 [mm] L3 [mm] L2 [mm] Lx 25A400 200 400 LEC 200 200 100 LEC S 0 0 0 0 5 10 15 20 0 10 5 15 20 0 10 5 15 20 LEC SS-T Work load [kg] Work load [kg] Work load [kg] LEC Y Motorless
Bore size (mm) Max. stroke Standard stroke (mm) 32 2560 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 40 2540 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 50 2520 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 63 2510 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 80 2430 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 100 2470 25, 50, 80, 100, 125, 160
Bore size/Stroke (mm) Data 10 25, 50, 75, 100 16 25, 50, 75, 100, 125, 150, 175, 200 End lock 20 25, 50, 75, 100, 125, 150, 175, 200 25 25, 50, 75, 100, 125, 150, 175, 200 R End lock 32 (25), 50, 75, 100, 125, 150, 175, 200 Nil None Note 1) For (25) stroke, the shock absorber is mounted on a single side of the plate.