SMC Corporation of America
Elite Part Number Search
Search Results "RZQA32TN-50-45-M9N"

Mounting: A (Both Ends Tapped), Bore Size: 32mm, Thread: TN (NPT Thread), Full Stroke: 300mm, First Stroke: 50mm, Auto Switch: M9N--Solid State , Gen. Purpose, 3 Wire NPN, Horizontal

Mounting: A (Both Ends Tapped), Bore Size: 32mm, Thread: TN (NPT Thread), Full Stroke: 50mm, First Stroke: 30mm, Auto Switch: M9N--Solid State , Gen. Purpose, 3 Wire NPN, Horizontal

Mounting: Both Ends Tapped, Bore Size: 32mm, Thread: NPT Thread, Full Stroke: 300mm, First Stroke: 50mm, Auto Switch: M9N--Solid State , Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: -, Number: -

Mounting: Both Ends Tapped, Bore Size: 32mm, Thread: NPT Thread, Full Stroke: 50mm, First Stroke: 30mm, Auto Switch: M9N--Solid State , Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: -, Number: -

, 50 Replacement Parts: Seal Kits Theoretical Output Table OUT IN Unit: N Bore size (mm) Contents Kit No.

mm 190 30 MIS12-30D 30, 50 mm 300 10 MIS20-10D 20MIS 5 15 355 20 MIS20-20D Data 410 30 MIS20-30D 800 30 MIS25-30D 10 15 1000 50 MIS25-50D 1350 30 MIS32-30D 18 50 1650 50 MIS32-50D 10-11-9 9 Series MIW/MIS Construction: Double Finger Type (MIW) 8 12, 20 w i !

mm 190 30 MIS12-30D 30, 50 mm 300 10 MIS20-10D 20MIS 5 15 355 20 MIS20-20D Data 410 30 MIS20-30D 800 30 MIS25-30D 10 15 1000 50 MIS25-50D 1350 30 MIS32-30D 18 50 1650 50 MIS32-50D 10-11-9 9 Series MIW/MIS Construction: Double Finger Type (MIW) 8 12, 20 q y r !

IC circuit Reed switch Solid state switch A96 A96V 5 V Grommet Yes Relay, PLC A93 A93V 12 V 2-wire 24 V 100 V 3-wire (NPN) M9N M9NV 5 V, 12 V IC circuit 3-wire (PNP) M9P M9PV 2-wire M9B M9BV 12 V Relay, PLC 3-wire (NPN) F9NW F9NWV 5 V, 12 V 24 V IC circuit Grommet Yes Diagnostic indication (2-color) 3-wire (PNP) F9PW F9PWV F9BW F9BWV 12 V 2-wire Water resistant (2-color) F9BA Although it

Information Solid-state Auto Switches for Direct Mounting Series D-M9N(V)/D-M9P(V)/D-M9B(V) Auto Switch Specifications Grommet PLC: Programmable Logic Controller D-M9/D-M9V (with Indicator light) Reduced load currents for two-wire model (2.5 to 40 mA) Compliance with lead-free requirements Use of UL-approved lead wires (style 2844) Three-wire D-M9N In-line Perpendicular D-M9P In-line

Note 2) There are four YA and YB dimensions with a 50 mm stroke.

MGTM100 200 P = 0.5 MPa 100 P = 0.5 MPa Load weight m(kg) Larger than 75st Load weight m(kg) 40 50 100 Larger than 50st 50st 25st 30 25, 50st 20 50 40 10 30 5 4 3 2 20 1 10 20 30 40 50 100 200 300 1 2 3 4 5 10 20 304050 100 200 300400 Eccentric distance l (mm) 10 400 Eccentric distance l (mm) Allowable side load F(N) 1 N: Approx. 0. 102 kgf F Stroke (mm) Bore size (mm) Model 25 50 75 100

Cushion Lubrication Piston speed Thread tolerance Stroke length tolerance Mounting Grease None Non-lube 50 to 400 mm/s Suction flow rate of vacuum suction type (Reference values) JIS Class 2 +0.5 0 Through-hole Suction flow rate l/min (ANR) 2 3 Fluorine grease Bore size 6/8 10 Particle generation grade (Refer to front matter pages 13 to 22 for details.) 10-: Grade 2, 11-: Grade 1 50 10CUJ

Usable stroke by buckling strength Usablestroke by Mounting style buckling strength (cm) Pressure Symbol and sketch (MPa) Symbol of bracket Rod side Frang e F Head side flange 103 92 113 Foot: 79 70 86 L G 66 58 72 45 38 47 33 27 34 26 22 27 96 83 106 Center Clevis trunnion 71 61 76 CD T 59 50 62 135 119 147 101 89 111 84 74 91 Rod side Frang e F Head side flange 301

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.1 to 1.0, Specification: Built-in magnet, Support bracket: Through-hole

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

: General Purpose, Maximum Load(kg): 68, Operating Speed(mm/s): 100~1500, Allowable Static Moment MA(N⋅m): 45, Allowable Static Moment MB(N⋅m): 33, Allowable Static Moment MC(N⋅m): 28, Connection Diameter: Rc1/4, Piping Format: Centralized piping type (standard), Port Screw Type: Rc, Auto Switches: M9N, Lead Wire Length(m): 3, Lead Wire Connector: None, The number of the switches: 2 pcs.,

: General Purpose, Maximum Load(kg): 68, Operating Speed(mm/s): 100~1500, Allowable Static Moment MA(N⋅m): 45, Allowable Static Moment MB(N⋅m): 33, Allowable Static Moment MC(N⋅m): 28, Connection Diameter: Rc1/4, Piping Format: Centralized piping type (standard), Port Screw Type: Rc, Auto Switches: M9N, Lead Wire Length(m): 3, Lead Wire Connector: None, The number of the switches: 2 pcs.,