0.2 A + Stroke M Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com E 25, 28 H thread effective depth C 2-Rc 1/8 F Q Y 2 x 4-OB Counterbore depth RB 2 x 4-OA effective depth RA J I 4-N through 0.2 D W E M K L B + Stroke 0.2 A + Stroke M E Bore size (mm) Stroke range
B + Stroke L M 0.2 A + Stroke E 25, 28 H thread effective depth C 2-Rc 1/8 2 x 4-OB Counterbore depth RB 2 x 4-OA effective depth RA Y Q F E J I 4-N through M 0.2 D W K B + Stroke L A + Stroke M 0.2 E Bore size (mm) Stroke range (mm) F A H B C D E OA I J K L M N OB Q RA W Y RB 10 10 to 40 69.5 M3 x 0.5 61.5 6 6 29 9 M4 x 0.7 38 5 8 20 3.5 6.5 39.5 7 5 4 16 10 to 60 80.5 M4 x 0.7 70.5 8
A + Stroke M 0.2 E 25, 28 H effective thread depth C 2-Rc 1/8 F Q Y 2 x 4-OA effective depth RA 2 x 4-OB Depth of counter bore RB J I 4-N through M 0.2 D W E K L B + Stroke M 0.2 A + Stroke E (mm) Bore size (mm) Stroke range (mm) OA A B C D E F H RB I J K L M N OB Q RA W Y M4 x 0.7 4 14.5 7 5 M3 x 0.5 10 to 40 39.5 31.5 6 6 29 5.5 10 38 5 8 20 3.5 6.5 M6 x 1.0 7 18 10 5 M4 x 0.7 10 to
S + Stroke ZZ + Stroke With rod boot l h + l ZZ + l + Stroke Bore size (mm) Stroke range A B1 BC BN BZ C D E GA GB GC GD GK GL GQ GR I J K KA MM NA AL 20 25 32 40 26 31 38 47 4 7 7 8 4 7 7 8 5.5 9 9 11 3.5 4 4 4 54 62 62 67 19 20 21 23 12 12 11 12 85 95 95 103 12 14 18 25 14 16.5 20 26 57.5 69 69 76 91 101 102 111 38 45 45 52 13 17 17 19 24 29 36 44 18 22 22 30 M8 x 1.25 M10 x 1.25 M10 x
The SY5100-X30 is a 5-port single solenoid valve with spool position detection and a spring return spool. The return spring assures the return of the valve to the safe state when de-energized without requiring pilot pressure. The built-in switch provides an ON signal when the valve is de-energized in its safe state and an OFF signal when the valve is energized.
The SY5100-X31 is a single solenoid valve for controlling the pilot air supply to the dwonstream valves within its zone. De-energizing the SY-X31 renders the downstream valves inoperable in response to a safe fault or for maintenance purposes. The return spring assures the return of the valve to the safe state when de-energized without requiring pilot pressure.
The SY5100-X310 is a single solenoid valve for controlling the pilot air supply to the downstream valves within its zone. De-energizing the SY-X310 renders the downstream valves inoperable in response to a safe fault or for maintenance purposes. The return spring assures the return of the valve to the safe state when de-energized without requiring pilot pressure.
The SY5100-X30 is a 5-port single solenoid valve with spool position detection and a spring return spool. The return spring assures the return of the valve to the safe state when de-energized without requiring pilot pressure. The built-in switch provides an ON signal when the valve is de-energized in its safe state and an OFF signal when the valve is energized.
The SY5100-X31 is a single solenoid valve for controlling the pilot air supply to the dwonstream valves within its zone. De-energizing the SY-X31 renders the downstream valves inoperable in response to a safe fault or for maintenance purposes. The return spring assures the return of the valve to the safe state when de-energized without requiring pilot pressure.
NJ NJ NI Width across flats KA MM Width across flats B1 EY EY NY C H1 AL 4-ND through 4-ET B A NB NA K 2 x 4-NC counterbore Prepared hole diameter NE H S + Stroke ZZ + Stroke BY BB BS + Stroke BA 2-BT (mm) Stroke range Model A BY D GW GY H H1 B1 C B AL BA BB BP BS BT ET GA GA1 GB GC GC1 EY 22 26 30 35 19.5 23.5 27 32 24 28 32 39 8 6.5 9 12 9 6.5 8 10 17 19 22 27 MLUB25 MLUB32 MLUB40 MLUB50
H2 P ZZ1 + Stroke GB GA Unlocks when pressurized BP unlocking port Front cylinder port GC D GW GY NH (manual unlocking unit) Dust cover P Rear cylinder port NS + Stroke NG NF NJ NJ NI Width across flats KA MM Width across flats B1 EY EY NY C H1 AL 4-ND through 4-ET B A NB NA K 2 x 4-NC counter bore Prepared hole diameter NE S + Stroke H ZZ + Stroke BY BB BS + Stroke BA 2-BT (mm) Stroke range
Dimensions/20 to 40 Basic/CM2YB Width across flats B2 2-P (Port size) (Rc, NPT, G) 2-NN H1 H2 G G Width across flats B1 I 2-Eh8 D MM AL A F F NA 1.5 1.5 N N K H S + Stroke ZZ + Stroke Boss-cut ZZ + Stroke (mm) A AL B1 B2 D E F G H H1 H2 I K MM N NA NN P S ZZ Bore size (mm) 20 25 32 40 0 0.033 0 0.033 0 0.033 0 0.039 18 15.5 13 26 8 13 8 41 5 8 28 5 M8 x 1.25 15 24 M20 x 1.5 1/8 62 116 20
B Port Size: Base Mounted Valve, Thread: Rc (or No Selection in the Case of One-touch Fittings), Mounting Option: K [Round head combination screw (Falling-out prevention type)], Pressure Sensor: None, NA: NA
Actuation: 2 Position Single, Mounting/Porting: Base Mounted, Seal: Rubber, Pilot Specification: Internal Pilot, Back Pressure Check Valve: None, Pilot Valve: Standard (0.7MPa), Coil Specification: Standard, Voltage: 24VDC, Light/Surge Suppressor/Common Specification: w/Light Surge Voltage Suppressor, Negative Common, Manual Override: Non-locking Push Type, A,B Port Size: Base Mounted Valve
Actuation: 1 (2-position Single), Mounting/Porting: 0 (Base Mounted), Seal: 0, Back Pressure Check Valve: None, Pilot Valve: Standard (0.7 MPa), Coil Specification: Standard, Voltage: 5 (24 VDC), Light/Surge Suppressor/Common Specification: NZ (w/Light/Surge Voltage Suppressor, Negative Common), Manual Override: Non-locking Push Type
Actuation: 2-position Single, Mounting/Porting: Base Mounted, Seal: -, Back Pressure Check Valve: None, Pilot Valve: Standard (0.7 MPa), Coil Specification: Standard, Voltage: 24 VDC, Light/Surge Suppressor/Common Specification: w/Light/Surge Voltage Suppressor, Negative Common, Manual Override: Non-locking Push Type, A, B Port Size: -
C1 Model (Stock item) Pressure range Note) Model Unit Connecting Note (kPa) GZ46-K-01 to 02 100 to 0 1 8 1 8 1 4 kPa R , kPa With covering assembly GZ46-K-01 to 02-C, C1 100 to 0 R ,1 4 1 8 1 4 kPa GZ46-K-01 to 02M 100 to 0 GZ46-K2K-01 to 02 100 to 200 R , M5 (Female thread) kPa GZ46E-K-01 to 02M 100 to 0 1 8 1 4 R , M5 (Female thread) R , 1 8 1 4 kPa Note) Do not apply pressure that exceeds
The xponent K (kappa) for air is 1.4.
The xponent K (kappa) for air is 1.4.