(Coil temperature: 20C, at rated voltage, without surge voltage suppressor) Note 4) For VFR600-FZ-06, ( ): VFR610-DZ-06 3-5-93 94 Series VFR6000 How to Order Option Electrical entry Nil Z None With light/surge voltage suppressor F: Plug-in type, conduit type Not applicable to grommet terminal.
The conversion conditions can be switched to 20C and 101.3kPa for the high flow rate types.
(mm) 2 x 1.2 Fluid Air, Water Max. operating pressure (at 20C) 0.8MPa Burst prssure Refer to pressure characteristics curve.
(mm) 2 x 1.2 Fluid Air, Water Max. operating pressure (at 20C) 0.8MPa Burst prssure Refer to pressure characteristics curve.
/32" 3/16" 5/16" 3/8" 1/2" 5/32" 5/16" 3/8" 3/16", 1/4" Flow rate (L/min (ANR)) 180 230 100 260 390 660 790 460 920 1580 1710 Controlled flow Free flow Sonic conductance dm3/(sbar) 0.54 0.7 0.3 0.8 1.2 1.4 2 2.4 2.8 4.8 5.2 Critical pressure ratio Controlled flow 0.25 0.3 0.25 0.25 0.2 Free flow 0.2 0.3 0.2 0.3 0.4 Note) Flow rate values are at a pressure of 0.5 MPa and a temperature of 20C
3/8" 1/4" Inch size 5/32" 3/16" 5/16" 3/8" 1/2" 5/32" 5/16" 3/8" 3/16", 1/4" Controlled flow Free flow Flow rate (L/min (ANR)) 180 230 100 260 390 660 790 1580 1710 460 920 Sonic Conductance dm3/(sbar) 0.54 0.7 0.3 0.8 1.2 1.4 2 2.4 2.8 4.8 5.2 Critical pressure ratio Controlled flow 0.2 0.25 0.3 0.25 0.25 Free flow 0.4 0.2 0.3 0.2 0.3 Note) Flow rate values are measured at 0.5 MPa and 20C
TMH ASD AS Maximum return speed (mm/s) 100 200 300 Speed Controller Cylinder Solenoid valve Tubing Silencer AS-FE 6 ASD230FG CJ2 SYJ500 TU0604 1 m AN11001 KE 10 16 Cylinder size AS-FG AS-FG 20 ASD330FG CM2 SYJ700 TU0604 1 m AN11001 Cylinder size 25 AS-FP 32 Values at 0.5 MPa and 20C.
REC 1/8", 5/32", 3/16" 1/4" 3/16", 1/4" 5/16" 1/4", 5/16" 3/8" 1/8", 5/32" 5/32" 3/16" Inch size 7 12 Air flow (l/min (ANR)) 38 Controlled flow CX 0.1 0.2 Effective area (mm2) 0.6 CY 100 180 230 260 390 460 Flow rate (l/min (ANR)) Free flow 1.5 2.7 3.5 4 6 7 Effective area (mm2) MQQ M Note) Supply pressure: 0.5 MPa, Temperature: 20C In-line Type RHC Air Flow/Effective Area MK(2) AS2001FM
Elbow Type (Metal body) Air Flow/Effective Area AS220M-02 AS120M AS220M-01 Model R 1/4 Cylinder side M5 x 0.8 10-32 UNF NPT 1/8 NPT 1/4 R 1/8 Port size Rc 1/4 Tube side Rc 1/8 Air flow (L/min (ANR)) 38 7 12 REA Controlled flow Effective area (mm2) 0.6 0.1 0.2 Flow rate (L/min (ANR)) 420 105 280 REB Free flow Effective area (mm2) 6.5 1.6 4.3 Note) Supply pressure: 0.5 MPa, Temperature: 20C
REC 1/8", 5/32", 3/16" 1/4" 3/16", 1/4" 5/16" 1/4", 5/16" 3/8" 1/8", 5/32" 5/32" 3/16" Inch size 12 7 Air flow (l/min (ANR)) 38 Controlled flow CX 0.2 0.1 Effective area (mm2) 0.6 CY 100 180 230 260 390 460 Flow rate (l/min (ANR)) Free flow 1.5 2.7 3.5 4 6 7 Effective area (mm2) MQQ M Note) Supply pressure: 0.5 MPa, Temperature: 20C Courtesy of Steven Engineering, Inc.-230 Ryan Way, South
Cool from 30C (303 K) to 20C (293 K). Circulating fluid : Tap water Density : 1 x 103 kg/m3 Specific heat C : 4.2 x 103 J/(kgK) Refer to the information shown below for the typical physical property values by circulating fluid. Water bath Q = T x V x x C h x 60 x 1000 10 x 2 x 1 x 103 x 4.2 x 103 20C V = 15 x 60 x 1000 After 15 min, = 93.3 W cool 30C down to 20C.
Furthermore, abnormal temperature rises caused by adiabatic compression may result in the burst of the tube. 3.The value of the minimum bending radius is measured at the temperature of 20C as shown in the figure on the right. Bend the tube into U-form at a temperature of 20C. Fix one end and close loop gradually. Measure 2R when the tube breaks or is crushed. Fixed end 1232
. *5 Inlet pressure: 0.7 MPa Flow at 20C, atmospheric pressure, and 65% of the relative humidity 7 Compressed Air Preparation Filter AFF/AM/AMD Series Line Filter AFF Series Flow Rate Characteristics (Representative values) AFF/AM/AMD AMK Modular Connection Example Compressed air over the max. flow capacity line in the table below may not meet the specifications of the product.
Approx.1200W(water), 800W(Fluorinert FC-77) Cooling capacity Conditions: set temp. 25C, ambient temp. 25C, radiating water temp. 20C, radiating water flow rate 10 L/min Approx.2200W(water), 1500W(Fluorinert FC-77) Heating capacity Conditions: set temp. 25C, ambient temp. 25C, radiating water temp. 20C, radiating water flow rate 10 L/min Recirculating fluid : Water, Fluorine solvent(GALDEN
MHK2-12S 120 12 9 4 9 13 76 Normally open Normally closed MHK2-16S 16 23 6 14.6 20.6 114 DL1 MHK2-20S 20 34 10 16 26 237 L2 MHK2-25S 25 58 14 19 33 443 20MHK2-12C 12 12 4 9 13 76 MHK2-16C 16 25 6 14.6 20.6 115 MHK2-20C 20 44 10 16 26 237 MHK2-25C 25 73 14 19 33 443 Series MHKL2/Long Stroke Type Note) Width at opening (mm) L2 Width at closing (mm) L1 Effective gripping force per finger (N)
Material Case Note 1 Stainless steel 316 Electrolytic polishing (Interior/Exterior) V-clamp 2 Stainless steel 304 Holder 1 3 Polyester Holder 2 4 Filter medium 5 Element PTFE Seal 6 FKM V-seal 7 300 SFA100/200/300 Series Clean Gas Filter: Cartridge Type/Disc Type Flow Rate Characteristics Fluid: Compressed air Inlet temperature: 20C Dimensions SFA100/101, SFA200/201, SFA300/301 SFA10 Inlet
) Max. operating pressure (at 20C) 0.8MPa 1.5MPa Refer to series TU burst pressure characteristics curve.
size 3.2, 4, 6 3.2, 4 6, 8, 10 8, 10 4 6 6 8 10 12 10, 12 Tubing O.D. 1/8", 5/32" 1/8" 3/16", 1/4" 1/4", 5/16" 3/8" 1/4" Inch size 5/32" 3/16" 5/16" 3/8" 1/2" 5/32" 5/16" 3/8" 3/16", 1/4" Controlled flow (Free flow) Flow rate (l/min (ANR)) 100 180 230 260 390 660 790 1580 1710 460 920 Effective area (mm 2) 1.5 2.7 3.5 4 6 7 10 12 14 24 26 Note) Flow rate values are measured at 0.5 MPa and 20C
AK ASS ASR ASF Flow Rate and Effective Area JIS Symbol ASD230FM ASD330FM ASD430FM Model 6, 8 8, 10 6 Metric size 4, 6 Tubing O.D. 1/8", 5/32" 3/16", 1/4" 1/4", 5/16" 3/8" 3/16", 1/4" Inch size Flow rate (l/min(ANR)) Controlled flow (Free flow) 7 12 38 0.1 0.6 0.2 Effective area (mm 2) Note) Flow rate values are measured at 0.5 MPa and 20C.
8, 10 3.2, 4 4 6 6 8 10, 12 10 12 Tubing O.D. 1/8", 5/32" 3/16", 1/4" 3/16", 1/4" 5/16" 1/4", 5/16" 3/8" 1/8" 5/32" 1/4" Inch size 5/32" 3/16" 5/16" 3/8" 3/8" 1/2" Flow rate (l/min (ANR)) 100 230 180 260 390 460 660 790 920 1580 1710 Controlled flow (Free flow) 1.5 3.5 2.7 4 6 7 10 12 14 24 26 Effective area (mm2) Note) Flow rate values are at a pressure of 0.5 MPa and a temperature of 20C