(Variation: 10%) Note 2) The value at ambient temperature of 20C and when the rated voltage is applied. The value depends on the ambient environment. This is for reference. Note 1) The value at ambient temperature of 20C and when the rated voltage is applied.

1048576 p/rev) 25APower consumption [W] Note 6) Horizontal 45 65 210 Vertical 145 175 230 LEC Standby power consumption when operating [W] Note 7) Horizontal 2 2 2 Vertical 8 8 18 LEC S Max. instantaneous power consumption [W] Note 8) 445 725 1275 Type Note 9) Non-magnetizing lock Lock unit specifications LEC SS-T Holding force [N] 78 131 255 131 197 385 220 330 660 Power consumption at 20C

drain Float type (Normally closed) Float type (Normally open) Refrigerant R407C (HFC) IDF D Port size Rc3/8 Rc1/2 Rc3/4 Rc1 Weight [kg] 16 17 18 22 23 27 28 46 Coating color Body panel: White 1 Base: Gray 2 Applicable air compressor output [kW] (Reference) For screw type 0.75 1.5 2.2 3.7 5.5 7.5 11 15 Refrigerant R134a (HFC) IDU E *1 Air flow capacity under the standard condition (ANR) [20C

Electrical characteristics Specified Layout Item Property Connector Manufacturers Example Conductor resistance h/km, 20C 65 or less Fujitsu Limited Japan Aviation Electronics Industry, Limited J.S.T. Mfg. Co., Ltd. HIROSE ELECTRIC CO., LTD. A mixture of single and double wiring can be specified on the manifold specification sheet.

[Example of setting] Circulating fluid SP: 20C (1) High Temp. CH1 circulating fluid temperature rise (AL10): 22C (2) Low Temp.

0.7 MPa Pressure 0.7 MPa 50 Pressure 0.7 MPa Pressure 0.7 MPa Pressure 400 0.6 MPa 0.6 MPa Gripping force (N) Gripping force (N) 0.6 MPa 0.6 MPa 0.6 MPa 0.5 MPa 0.5 MPa 40 300 0.5 MPa 0.5 MPa 0.5 MPa 0.4 MPa 0.4 MPa 30 0.4 MPa 0.4 MPa 0.3 MPa 0.3 MPa 200 20 0.3 MPa 0.3 MPa 0.25 MPa 0.25 MPa 100 10 0 10 20 30 40 50 60 0 20 40 60 80 100 120 Gripping point L (mm) Gripping point L (mm) MHZ2-20C

0.7 MPa Pressure 0.7 MPa 50 Pressure 0.7 MPa Pressure 0.7 MPa Pressure 400 0.6 MPa 0.6 MPa Gripping force (N) Gripping force (N) 0.6 MPa 0.6 MPa 0.6 MPa 0.5 MPa 0.5 MPa 40 300 0.5 MPa 0.5 MPa 0.5 MPa 0.4 MPa 0.4 MPa 30 0.4 MPa 0.4 MPa 0.3 MPa 0.3 MPa 200 20 0.3 MPa 0.3 MPa 0.25 MPa 0.25 MPa 100 10 0 10 20 30 40 50 60 0 20 40 60 80 100 120 Gripping point L (mm) Gripping point L (mm) MHZ2-20C

Note) l/min (ANR) is for reference conditions of 20C, 1 ATM and 65% relative humidity. Features 3 Model Selection Data A Correction factor for temperature/Series IDU Inlet air temp.

Specifications Grade 1 Note 1) Particulate generation grade Air, Nitrogen gas, Water (pure water) Note 2) Fluid 1MPa Note 3) Maximum operating pressure (20C) 100kPa Operating vacuum pressure Caution 3MPa Proof pressure (20C) 20C to 80C Ambient and fluid temperature Series KP is a line of special One-touch fittings for use in clean room blowing and washing lines.

Item Property Conductor resistance /km, 20C 65 or less Voltage limit V, 1 minute, AC 1000 Circular connector cable assembly Insulation resistance M/km, 20C Note) When using the negative COM specification, use valves for negative COM. 5 or more Assembly part no.

Lead wire length 0 1 2 0.6 m 1.5 m 3.0 m Electrical characteristics Item Characteristic Sheath Colour: Urban white Conductor resistance /km, 20C 65 or less Withstand pressure V, 1 minute, AC 1000 Polarity Terminal no. Lead wire colour Dot marking Insulation resistance M/km, 20C 5 or more 1 () (+) Black None SOL. A 14 () (+) Yellow Black Station 1 SOL.

Insulation resistance M/km, 20C 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 5 or more Note) The minimum bending radius of the D-sub connector cables is 20 mm.

Flow at 20C, atmospheric pressure, and 65% of the relative humidity The maximum flow capacity varies depending on the inlet pressure.

Note 2) Safety allowance x3 at 20C Note 3) To calculate flow factor for longer lengths of tube divide factor for 1 metre by actual length in meters.

Flow rate conversion NO OFF n-2 n-1 High flow rate Basic state: 0C, 101.3kPa Standard state: 20C, 101.3kPa, 65%RH (ANR) Switchable between these states.

Note 2) Flow rate display can be switched between the basic condition of 0C, 101.3 kPa and the standard condition (ANR) of 20C, 101.3 kPa, and 65% RH. Note 3) Without lead wire. Note 4) Accumulated flow rate is reset when the power supply turns OFF. Note 5) Switch output and accumulated pulse output can be selected during initial setting.

Standard Specifications/Single Unit (Standard Dew Point 20C) Membrane Air Dryer Series IDG Model Standard dew point: 20C IDG5 IDG10 IDG20 IDG30 IDG50 Fluid Compressed air Macromolecular membrane dryers that act like filters. -20C low dew point just by installing in air pressure line.

The value of the minimum bending radius is measured at the temperature of 20C as shown below. KP LQ MQR Bend the tube into U-form at a temperature of 20C. Fix one end and close loop gradually. Measure 2R when the tube breaks or is crushed. T T Fixed end IDK 3.

Note 2) The maximum operating pressure is the value at 20C. Refer to the burst pressure characteristics curve for other temperatures. Furthermore, an abnormal temperature rise due to adiabatic compression can cause tubing to burst. Note 3) The minimum bending radius indicates the value at a temperature of 20C with an outside diameter change rate of 10% or less.

(mm) 7.3 5.8 4.4 2.8 8.8 Black (B) White (W) Bend the tube into U-form at a temperature of 20C. Fix one end and close loop gradually. Measure 2R when the tube breaks or is crushed. Blue (BU) Fixed end Translucent (N) Fluid Air 20C 0.8 Max.