SMC Corporation of America
Elite Part Number Search
Search Results "ZA1051-K15L-P1-52"

Flow Characteristics Air pressure 0.7 MPa (Example) To get pressure drop at 0.3 MPa of air pressure, 2000 l/min (ANR) of air flow, and model HAA22, use P = 0.0007 MPa from the table and convert P1 to 0.3 MPa.

Thermometer Air outlet Air inlet Outside tube Pressure drop (MPa) Cooling water outlet Cover Cooling water inlet Drain separator (Housing) Water chamber cover Stop valve Flower fin tube assembly Drain Air flow rate (m3/min (ANR)) (Example) To get pressure drop at 0.3 MPa of air pressure, 5 m3 /min (ANR) of air flow and model HAW75-20, use 0.0065 MPa at 0.7 MPa from the table and convert P1

The inlet pressure obtained in the flow characteristic graph of silencer indicates the pressure (P1) prior to silencer. (Refer to the diagram below.)

(the condition of P1 and Q1) 3. If the suction port is opened completely, the suction flow rate increases to the maximum (Qmax), while the vacuum pressure then drops almost to "0" (atmospheric pressure).

Vs: Power supply 24VDC 12 to 15VDC One of the preset pressures P1 through P4 is selected by the ON/OFF combination of S1 and S2. S1 S2 Preset pressure OFF OFF P1 ON OFF P2 OFF ON P3 ON ON P4 For safety reasons, it is recommended that one of the preset pressures be set to 0MPa.

(the condition of P1 and Q1) 3. If the suction port is opened completely, the suction flow rate increases to the maximum (Qmax), while the vacuum pressure then drops almost to 0 (atmospheric pressure). When adsorbing work pieces which are permeable or subject to leakage, etc., caution is required as the vacuum pressure will not be very high.

Pressure gauge port size Port size Model AR425/435 AR625/635 AR825/835 AR925/935 1/4, 3/8, 1/2 3/4, 1 1 , 1 2 80 98 126 160 145.5 155 216 241 3 7 5 10 1/4 1/4 1/4 1/4 39.5 43 75 90 50.0 85 48 52 80 90 B24P B25P 67 78 110 140 73 78.5 94.5 4 1 2 1 109.5 680

A B D +0.058 0 +0.2 +0.1 +0.2 +0.1 +0.3 +0.1 +0.3 +0.1 AD-EI-20 AD-EI-25 AD-EI-32 AD-CHN-40 -0.016 -0.034 -0.016 -0.034 -0.016 -0.034 -0.016 -0.034 Y-02 Y-03 Y-04C YHN-04 20 25 32 40 45.5 45.5 52 60 35.5 35.5 42 50 3.2 3.2 4 4 10 10 12 16 9 9 16 16 36 38 55 55 16 18 22 22 9 9 12 15 20 25 32 40 12 12 13 13 20 20 24 24 14 14 25 25 18 18 38 38 M8 x 1.25 M10 x 1.25 M14 x 1.5 M16 x 1.5 3.2 x 16l

Dimensions Padlock mounting position (Port size) (Port size) Standard specifications Model P1 P2 A B C D E F G H VHS20 1/8, 1/4 1/8 71.5 23 40 37 28 42 17.5 40 VHS30 1/4, 3/8 1/4 87 32 53 49 38 53 20 53 VHS40 1/4, 3/8, 1/2 3/8 111 42.3 70 63 52 71 29 70 1 0 - Revision history Rev. A Safety Instructions (Piping) corrected.

Pressure gauge port size Port size Model AR425/435 AR625/635 AR825/835 AR925/935 1/4, 3/8, 1/2 3/4, 1 1 1/4, 1 1/2 2 145.5 155 216 241 39.5 43 75 90 73 78.5 94.5 109.5 3 7 5 10 1/4 1/4 1/4 1/4 67 78 110 140 46.5 85 48 52 80 90 B24P B25P 80 98 126 160 14-4-17

Effective area (Cv) Max. operating frequency 0.8MPa 0.15MPa 5 to 50C 2.7mm2 (0.15) 180 c.p.m To CYL port SUP side pressure (P1) (1) Note 1) As per JISB8375-1981 (Supply pressure: 0.5MPa) Dimensions 21.5 (5) Valve Manifold 18 29 10.5 2n-C4, C6 C4: One-touch fitting ass'y for 4 2n-C4, C6 C4: One-touch fitting ass'y for 4 C6: One-touch fitting ass'y for 6 L1 L2 L3 C6: One-touch fitting ass'y

This is a legacy product, and replaced byZQ1103M-K15L-EAG-0

This is a legacy product, and replaced byZL112A-K15L-DBPL, Vacuum Ejector, VACUUM EJECTOR, 625 lb

This is a legacy product, and replaced byZQ101UA-K15L-EAG-00, VACUUM EJECTOR, VACUUM SERIES, ZQ VACUUM EJECTOR, BH, ZQ NOZZLE SIZE 0.7, .47741 lb, ModelNozzle nominal diameter (mm)Maximum suction flow (l/min (ANR))Air consumption (l/min (ANR))Maximum vacuum pressureSupply pressure rangeSupply pressure Note)Operating temperature rangeFluidZQ1101.02246?

This is a legacy product, and replaced byZQ101UA-K15L-EBG-00, VACUUM EJECTOR, VACUUM SERIES, ZQ VACUUM EJECTOR, BH, ZQ NOZZLE SIZE 0.7, .44092 lb, ModelNozzle nominal diameter (mm)Maximum suction flow (l/min (ANR))Air consumption (l/min (ANR))Maximum vacuum pressureSupply pressure rangeSupply pressure Note)Operating temperature rangeFluidZQ1101.02246?

This is a legacy product, and replaced byZQ1101U-K15L-EAG-00, VACUUM EJECTOR, VACUUM SERIES, ZQ VACUUM EJECTOR, CA, ZQ NOZZLE SIZE 1.0, 0.40831 lb

This is a legacy product, and replaced byZQ103MA-K15L-EBG-0 ZQ VACUUM EJECTOR. VACUUM EJECTOR. VACUUM SERIES. ZQ NOZZLE SIZE 1.0. .24030 lb. CA.

Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: K1 (Supply: NC, Release: NC), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Suction Filter: F (Suction Filter), Pressure Sensor Specs: P1 (Pressure Sensor, 0 to -101kPa, Accuracy ±2% F.S

Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: K1 (Supply: NC, Release: NC), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Suction Filter: F (Suction Filter), Pressure Sensor Specs: P1 (Pressure Sensor, 0 to -101kPa, Accuracy ±2% F.S

Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: K1 (Supply: NC, Release: NC), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Suction Filter: None, Pressure Sensor Specs: B (w/o Pressure Sensor), Air Pressure Supply, P Port: 2 (ø4, Straight