Vacuum ejector series ZA is compact and lightweight, making it ideal for pick and place operations, and suitable to all industries. Due to the compact design of the ZA, it is possible to install on moving parts. The shortened tube length to pad improves response time. The ZA is available as a single unit or manifold type, with or without pressure sensors and suction filters. Compact
Vacuum ejector series ZA is compact and lightweight, making it ideal for pick and place operations, and suitable to all industries. Due to the compact design of the ZA, it is possible to install on moving parts. The shortened tube length to pad improves response time. The ZA is available as a single unit or manifold type, with or without pressure sensors and suction filters. Compact
Heater: Indicator: 5 Aluminum High Vacuum Angle Valve XLA/XLAV Series Dimensions XLA: Air operated (b) E C E C E Fn (KF flange) Fd (K flange) (a) D Heater (Option) Auto switch (Option) (c) [mm] Model A B C D E*1 Fn Fd G H XLA-16-2 40 108 38 20 30 17 44 XLA-25-2 50 121 48 27 12 40 26 44 XLA-40-2 65 171 66 39 11 55 41 67 XLA-50-2 70 185 79 46 11 75 52 72 XLA-63-2 88 212 100 55 11 87 95
62.5 10.3 10.9 10.3 10.9 12.3 13.4 12.3 13.4 36.5 44 55 62.5 Note 1) ;in the table indicates the pad material "N, S, U, F, GN, GS."
10 12 12 16 16 20 9.5 12 12 16 16 20 6.6 6.6 9 9 11 11 6.5 6.5 8.5 8.5 11 12 48 56 64 75 95 115 45 52 60 70 90 110 26 28 32 40 50 60 32 40 50 63 80 100 C85 C76 CG1 Rear Sngle Clevis DS MB MB1 Bore (mm) E B1 H B2 B3 L3 L1 TG1 T d1 FL d2 d3 CN XD 45 55 65 75 95 115 14 16 21 21 25 25 5 5 5 5 5 5 11.5 12 14 14 16 16 3 4 4 4 4 4 10 12 16 16 20 20 30 35 40 45 45 55 34 40 45 51 65 75 3.3 4.3 4.3
D-A7 D-A80 D-A73C D-A80C 90 55 50 15 10 105 60 60 15 10 105 65 65 15 10 35 10 5 45 10 5 40 15 10 45 5 5 30 5 5 55 15 10 40 15 10 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 CP95 Symbol Specifications D-C7 D-C80 NCM -XA Change of rod end shape D-A7H D-A80H Band mounting style (6, 10, 16) -XB6 Heat resistant cylinder (150C) Not available with switch & with air cushion NCA -XB7 Not available
20 18 8 40 4 25 40 62 15.5 13 26 5 8 28 5 6.8 102 3.2 M8 x 1.25 15 24 M20 x 1.5 1/8 131 25 45 25 8 8 13 55 20 22 10 47 4 28 40 62 19.5 17 32 6 8 33.5 5.5 6.8 102 3.2 M10 x 1.25 15 30 M26 x 1.5 135 1/8 -X 32 45 25 8 8 13 55 20 22 12 47 4 28 40 64 19.5 17 32 6 8 37.5 5.5 6.8 104 3.2 M10 x 1.25 15 34.5 M26 x 1.5 137 1/8 40 50 27 11 10 16 75 23 24 14 54 4 30 55 88 21 22 41 8 10 46.5 7 7 134
Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: K1 (Supply: NC, Release: NC), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: M (M Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Suction Filter: F (Suction Filter), Pressure Sensor Specs: P3 (Pressure Sensor, -100 to 100kPa, Accuracy ±2%
Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: K1 (Supply: NC, Release: NC), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Suction Filter: F (Suction Filter), Pressure Sensor Specs: P3 (Pressure Sensor, -100 to 100kPa, Accuracy ±2%
Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: K1 (Supply: NC, Release: NC), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Suction Filter: F (Suction Filter), Pressure Sensor Specs: P3 (Pressure Sensor, -100 to 100kPa, Accuracy ±2%
Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: Q1 (Supply: Latching Positive Common, Release: NC), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Suction Filter: F (Suction Filter), Pressure Sensor Specs: P3 (Pressure Sensor, -100 to
Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: Q1 (Supply: Latching Positive Common, Release: NC), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Suction Filter: F (Suction Filter), Pressure Sensor Specs: P3 (Pressure Sensor, -100 to
Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: N1 (Supply: Latching Negative Common, Release: NC), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Suction Filter: F (Suction Filter), Pressure Sensor Specs: P3 (Pressure Sensor, -100 to
Main Body Shape: Unit, Additional Function: Filter, Ultimate Vacuum(kPa): -74, Air Consumption Flow Rate(l/min): 12, Vacuum Port Connecting Port Shape: One-Touch Couplings, Vacuum Port One-Touch Fitting Size: Ø4, Air Supply Port Connecting Shape: -, Air Supply Port One-Touch Fitting Size: -, Application: Manifolds, Operating Pressure Range(MPa): 0.2~0.5, Operating Temperature Range(°C): 5
Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: Supply: NC, Release: NC, Pilot Valve: Standard (1W for DC), Power Supply Voltage: 24VDC, Electrical Entry: M Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Suction Filter: Suction Filter, Pressure Sensor Specs: Pressure Sensor, -100 to 100kPa, Accuracy ±2% F.S., Air Pressure Supply
Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: Supply: NC, Release: NC, Pilot Valve: Standard (1W for DC), Power Supply Voltage: 24VDC, Electrical Entry: L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Suction Filter: Suction Filter, Pressure Sensor Specs: Pressure Sensor, -100 to 100kPa, Accuracy ±2% F.S., Air Pressure Supply
Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: Supply: Latching Positive Common, Release: NC, Pilot Valve: Standard (1W for DC), Power Supply Voltage: 24VDC, Electrical Entry: L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Suction Filter: Suction Filter, Pressure Sensor Specs: Pressure Sensor, -100 to 100kPa, Accuracy ±2%
Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: Supply: Latching Positive Common, Release: NC, Pilot Valve: Standard (1W for DC), Power Supply Voltage: 24VDC, Electrical Entry: L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Suction Filter: Suction Filter, Pressure Sensor Specs: Pressure Sensor, -100 to 100kPa, Accuracy ±2%
Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: Supply: Latching Negative Common, Release: NC, Pilot Valve: Standard (1W for DC), Power Supply Voltage: 24VDC, Electrical Entry: L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Suction Filter: Suction Filter, Pressure Sensor Specs: Pressure Sensor, -100 to 100kPa, Accuracy ±2%
322 QW 30 36 42 51 59 Z 160 200 220 280 340 NW 37 45 53 64 75 P M5 x 0.8 M5 x 0.8 Rc 1/8 Rc 1/8 Rc 1/4 YW 32 40 46 55 67 T 7 8 10 10 14 Model MY1B16 MY1B20 MY1B25 MY1B32 MY1B40 MY1B16 SMY1B16, #1 (#1 + #7) "P" indicates cylinder supply ports.