Step Request data Response data Operation details 1 01 06 0412 000A 01 06 0412 000A Sets Step Data No. 1 Positioning time to 0.1 sec. 01 10 0410 0002 2 01 10 0410 0002 Sets Step Data No. 1 Target position to 10 mm. 04 0 2710 (4) Return to Origin Change the Card Motor controller (controller ID1) operation mode to serial operation, and send a Return to Origin instruction.

These vortexes are stable under certain conditions, and their frequency is proportional to the flow velocity, resulting the following formula. f = k x v f: Frequency of vortex v: Flow velocity k: Proportional constant (determined by the vortex generator's dimensions and shape). Therefore, the flow rate can be measured by detecting this frequency.

CJ1 CJP CJ2 CM2 C85 C76 CG1 MB MB1 CP95 C95 C92 CA1 CS1 1.11-1 Series C95 Model Selection Options Piston Rod Model Execution Adjustable Stroke End Cushioning Standard Hard Chrome W R K C95 SB C95 SDB C95 ST C95 SDT C95 KB C95 KDB C95 KT C95 KDT C95 NB C95 NDB C95 NT C95NDT C95PB C95 PDB C95 QB C95 QDB C95 QT C95 QDT Standard Type With Mounting Centre Trunnion Non-Rotating Piston Rod Non Rotating

Compact 35mm Light weight 120g 50mm 66mm 270g 700g Pressure gauge can be mounted from the front or rear Rear pressure gauge mounting Standard Back Pressure gauge VAC SET SMC P (Vacuum pump side) (Pad side) K U C S O H L VAC SET L H O S C Pressure gauge Panel mounting capability is standard U K P SMC (Vacuum pump side) (Pad side) Front Applications Lifting of work pieces Leak tester Pressure

ASD Model Meter-out type Rod and applicable tubing O.D. 4 6 8 10 Meter-in type AS1000P-04-04 AS2000P-04-04 AS2000P-06-06 AS2500P-06-06 AS3000P-08-08 AS3000P-10-10 AS1010P-04-04 AS2010P-04-04 AS2010P-06-06 AS2510P-06-06 AS3010P-08-08 AS3010P-10-10 AS AS-FE KE The lock nut provides identification.

67 k 1 0 to 10V Note 2) Not conforming to ISO1179-1. 24 V 2 4 to 20 mA 120 3 0 to 20 mA 5 1 to 5 V 67 k 10 k 6 0 to 10 V 12 V 7 4 to 20 mA 120 8 0 to 20 mA Symbol Symbol B (Bracket) F (Foot) G (Pressure gauge) N (Silencer) Body size Port size Rc Option Applicable pilot valve (4) Mounting Port 1(P), 2(A) Port 3(R) 00 M5 00 M5 01 00 01 02 00 02 03 04 M5 01 02 02 03 04 04 06 10 10 12 14 20

P . 15-11-3 15-9-2 2 Speed Controller with One-touch Fitting Elbow Type/Universal Type Series AS How to Order 2 2 0 01 06 S AS 1F Nil Option Body size 1 2 3 4 M3, M5 standard 1/8, 1/4 standard 3/8 standard 1/2 standard None With seal Hexagonal lock nut Electroless nickel plated S K N If more than one option is required, write option part numbers in the order of S, K, N.

E Vacuum break flow adjusting needle Lock nut J Round lock nut u Vacuum (V) port K Screwdriver operation type Symbol Vacuum (V) port 06 6 08 8 Vacuum break flow adjusting needle ZK2 Combination Manifold Individual supply port L Manifold individual supply specification5 Fittings, Replacement Parts, Tools P With manifold common release pressure supply (PD) port Cannot be selected when e is

Note 3) K (High pressure) and Y (Low wattage) are not available. Electrical ently: L/ M plug connector only.

Applicable model 84 84 03 FGD-CV002-04 06 03 FGD-CV003-04 06 03 FGD-CV004-04 06 03 FGD-CV001-04 06 32 32 FGDT/F FGDT/F FGDC/E FGDC/E Note 1) Same as standard product except for cover assembly Note 2) 03, 04, and 06 indicate the relevant port sizes (Rc3/8, 1/2, 3/4).

L-type block (75) (50) W R P Q Port size Weight (kg) d K W Y AE (mm) (75) (50) W J W (mm) 1/2B (04) 3/4B (06) 1B (08) 1 1/4B (10) 1 1/2B (12) 2B (16) 2 1/2B (20) 3B (24) 22.2 27.7 34.5 43.9 49.1 61.1 77.1 90.0 47 47 47 50 50 50 50 50 70 70 70 85 85 85 105 105 9 9 9 9 9 9 9 9 62 62 62 65 65 65 65 65 3.5 3.5 3.5 6.2 6.2 6.1 11.9 11.9 Port size Weight (kg) E J P Q Port size Weight (kg) E 69

84 25 21 98 30 24 111 46 36 132 50 41 200 74 60 230 74 60 271 86 70 JIS Symbol 1 4 1 2 2 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Construction/Parts/Dimensions ANA1-01 to 06 Sound absorbing Case material (PFV ) End plate Hexagonal flats ANA1-06: PP How to

In-line type How to Order JIS Symbol 1F 12 K 400 AS Option Body size Nil K N None Hexagonal lock nut Electroless nickel plated If more than one option is required, write option part numbers in the order of K, N. M5 standard 1/8 standard 1/4 standard 3/8 standard 1/2 standard 100 200 205 300 400 Applicable tubing O.D.

(inch) 4 6 8 10 12 Accessory Model TM-04 TM-06 TM-08 2 x 6 T TM-04 TM-06 TM-08 TM-10 TM-12 2.6 x 8 4 TM-10 VMG 3 x 8 TM-12 Dimensions: Multi-tube Holder (Pitch) N-holding part Cutting groove for separation N (No. of holding parts) Applicable tubing O.D.

AM550-06, 10 P. 14-20-16 Mist separator 35 dB or more of noise reduction AMC310-03 AMC510-06 AMC610-10 Exhaust cleaner VBA2200-03 Air operated type VBAT05 (5 l, Directly connected to booster regulator) VBAT20 (20 l, Directly connected to booster regulator) VBAT38 (38 l, Directly connected to booster regulator) JIS Symbol Air tank VBAT10 (10 l, Directly connected to booster regulator) Handle

SY SYJ VK Blank plug KQP-23-X19 KQP-04-X19 KQP-06-X19 KQP-08-X19 KQP-10-X19 VZ L Dimensions VT A One-touch fitting d Part No. A L D VT KQP-23-X19 KQP-04-X19 KQP-06-X19 KQP-08-X19 KQP-10-X19 3.2 4 6 8 10 16 16 18 20.5 22 31.5 32 35 39 43 3.2 6 8 10 12 D VP Color: White VG VP L DIN rail AXT100-DR-l 12.5 (Pitch) 5.25 7.5 VQ Enter suffix number into l from the table below.

SY SYJ VK Blank plug KQP-23-X19 KQP-04-X19 KQP-06-X19 KQP-08-X19 KQP-10-X19 VZ L Dimensions VT (mm) A One-touch fitting d Part No.

Universal type (throttle valve) 10-AS2301F-01-06-X214 10-AS1301F-M5-06-X214 10-AS2301F-01-06-X214 1.