Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: M9BA, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: M9BA, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: M9BA, Lead Wire Length
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: M5 × 0.8, Auto Switches: M9BA, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: M9BA, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: M9BA, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 180, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: M9BA, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 180, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: M9BA, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: M9BA, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 280, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: M9BA, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 320, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: M9BA, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: M9BA, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: M9BA, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: M9BA, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: Ø32 mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 100mm, Body Option: CM (Rubber Bumper, Rod End Male Thread), Lock Position: H (Rear Locking), Release of Manual: N (Non-locking Type), Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: SBPC (0.5 m Cord
Bearing Type: M (Slide Bearing), Bore Size: 25mm, Thread Type: Rc; Bore Size 12, 16: M5 x 0.8, Stroke: 75mm, Stroke Adjustment: A (0 to 10), Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: SBPC (0.5m Cord Length, M8-4 Pin Connector), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: XC8 (Adjustable Stroke, Extension Type
Magnet: D (Built-in), Mounting: E (Double End), Bore Size: 200 (2"), Stroke: 2800 (28"), Cushion: C (Urethane), Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: SBPC (0.5m Cord Length, M8-4 Pin Connector), Number: 2 pcs. (Or None in the Case of No Switch), Temperature Option: Standard, Stainless Steel Option: X6009A (All Stainless Steel,