Flow Characteristics/Weight Flow characteristics 1 2 (P A) 2 3 (A R) 3 2 (R A) 2 1 (A P) Port size Weight Valve model Grommet C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv VT307 VT307V (Vacuum spec. type) VT307E (Continuous duty type) VT307Y (Energy-saving type) VT307W (Energy-saving, Vacuum spec. type) VT307 VT307V (Vacuum spec. type) VT307E
Indicator light Operating Range [mm] Auto switch model Bore size 16 20 25 32 40 50 63 D-M9NJ D-M9PJ 4.5 4.5 4.5 5 4.5 5 5 22 64.5 4 Since the operating range is provided as a guideline at room temperature, it cannot be guaranteed. It may change substantially depending on the ambient environment.
, 50A H (Valve open) Indicator (Option) Pilot port 12(P1), 10(P2) Port size: refer to table below P1 P2 F G E A 32 B D J Main port 1(A) (Back side 2(B)) C A B Port size: refer to table below Main port 1(A), 2(B) Pilot port 12(P1), 10(P2) A B C D E F G H J Model VND50D-32A VND60D-40A VND70D-50A 1 8 1 4 1 4 1 4 1 2 1 1 2 105 120 140 77 96 113 53 60 74 26.5 30 37 121.5 138 161 20 24 24 130.5
Temperature Data A or B = Series IDUS: Data A Series IDFS: Data B Air pressure Data C = 2 Calculate corrected air flow by using A or B and C. Corrected air flow = (Air flow) (Data A x Data C) Corrected air flow = (Air flow) (Data B x Data C) 3 Select a model having an air flow capacity that is higher than the corrected air flow.
A A A B A B P1 B B Section A-A (ejector) Section B-B (solenoid valve) Replacement parts list Parts list No. 1 2 3 4 5 6 7 8 Description Material No. Description Part No.
0.10.83MPa 2 -560 () 3) Rc 1/8 (kg) 0.46 mm2) A 21 18.5 11 P1=0.7MPa,P2=0.5MPaS PB 18.5 22 12 mm2) AEA 40 P2=0.5MPaS BEB 36 10 VFR3000-OMJ0001-A VFR3000 VFR3000 VFR3000 VFR3000 Series Series Series Series 4 4 4 4 01F D 01C COM A B 1)8 2) +COM -COM 3) D U D 1 COM A B 1)8 2) +COM -COM 3)D U D 1 11 VFR3000-OMJ0001-A () X () [3(EB) 4(EA)] ( (PE) 12 VFR3000-OMJ0001-A No. 1(ISO VG 32
M E N S I O N S AD S E R I E S A U I T O D R A I N S S Y M B O L S H O W T O O R D E R A U T O D R A I N S E R I E S AD AD402-02 (1/4) PT AD402-03 (3/8) PT AD402-04 (1/2) PT AD600-06 (3/4) PT AD600-10 (1) PT H O W T O O R D E R A U T O D R A I N S E R I E S NAD NAD402-N02 (1/4) NPT NAD402-N03 (3/8) NPT NAD402-N04 (1/2) NPT NAD600-N06 (3/4) NPT NAD600-N10 (1) NPT FOR FURTHER TECHNICAL DETAILS
P 2-TC TD D I E 0 -0.05 0 -0.05 E AL TE 2-TC K F TA DL2 TF TG A S + Stroke H NA F ZZ + Stroke Section TA With non-locking type manual override (suffix N) With locking type manual override (suffix L) HN HR MO RF WL WL KA 0.1 C 8-J NA (mm) Stroke range Bore size (mm) A AL B1 C D DL2 E F GA GB H H1 HR HN (max.)
Danger: DANGER indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. SET button Press this button to change the mode and to set a value.
Cylinder bore size Auto switch type Nil B30 B30J B31 B31J B35 B35J Without auto switch D-B30 D-B30J D-B31 D-B31J D-B35 D-B35J Mounting Cylinder model CDA1 MDB Series CDA1 (Bore size 40 to 100) Series MDB (Bore size 40 to 100) Consult P/A in case the switch is to be mounted on models other than applicable cylinders. 3
d C C B H B H Material: Carbon steel Material: Carbon steel Part no.
PF3A702H AC40#-D Y400-D Y400T-D E400-#04-D : For more information about the options, refer to our website (URL https://www.smcworld.com). 4 Snap shot function The current flow rate value can be stored to the switch output ON/OFF set point.
Odour Removal Filter : Series AMF Standard features MODEL FLOW PORT B C D WEIGHT ELEMENT A NPT in in in lb (cfm) Die-cast Aluminum with chromate treatment No screw threads or tie rods are required therefore removal and replacement of element is made quick and easy (AMF) Two sight glasses are fitted to the housing to give a visual indication of the filter operation and condition (AMF) in
Dimensions IN574-95 (Sensor head + Display part) 20 40 230 D-F8N (2 pcs.) 110 Red tape 500 20 M12 Connector Tube (3 places) Green tape Sensor head Wiring Terminal no. Description Note 1 +15 V 1 2 1 2 5 2 Output signal 1 D-F8N 3 4 3 4 Display part 3 GND Socket connector A-coded (Normal key) Plug connector A-coded (Normal key) 4 Output signal 2 D-F8N DD1677
Fine lock cylinder Series C(D)L RB Standard SCLAl 3.1-33 20-CLA J Cylinder with lock Series C(D)NA D SCNAl Standard 20-C(D)NA 3.3-1 -X End lock cylinder Series C(D)B 20Standard 20-CBM2 SCBM2l 3.4-4 Standard 20-CBA1 SCBA1l 3.4-12 Plate cylinder Series M(D)U Technical Data Standard 2.4-2 20-MU SMUl 2.4-6 Double rod 20-MUW Precision cylinder Series MTS 4.11-6 Standard MTS SMTSl 4.11-6 With
10VA 5W AC1500V1 AC500V 1 DC500V50 0+50 3585RH 1500V600V Hz 2 10G XYZ 3 250g 6 6 6 6 6 6 6 6-1 1 1 1 (DC12V60mA) B A G N D A B COM RS COM COM 12V G N D A B COM OUT1 AC100V OUT2 COM COM OUT3 COM DC24V GND AC100V (C E U 1) (C E U 1-D ) CEU1 +12V + 12V 1 A 680 CO M +12V + 12V 1 B 680 COM +12V D C 1 2 V60 m A GND RS COM FG AC100V 6 6 6 6-3 3 3 3 1C E U 1 CE1-R**
For a facility having a large installation area (that can vent the air naturally): Make an air outlet on a wall at a high level and air inlet on a wall at a low level, to allow for adequate airflow. 2. For a facility having a small installation area (that can not vent the air naturally): Make a forced air exhaust vent on a wall at a high level and an air inlet on a wall at a low level.