Q Approx. 300 F D Approx. 280 D Q F C G (PF) 1/2 C R R E E B A H 2-P Port size 2-P A B H 2-M Port size 2-M Thread depth N L L K K Conduit terminal: T F (Q) 34 25 U R C G (PF) 1/2 E B A H D 2-P Port size (S) 2-M L K N.C.
Safety Instructions Be sure to read the Handling Precautions for SMC Products (M-E03-3) and Operation Manual before use.
Symbol Specifications -X12 Lubricant: Vaseline -X21 Grease-free (Seal: Fluorine-coated) + Restrictor (Without check valve) -X214 Restrictor (Without check valve) 10Clean Series 565 A AS Series Needle Valve/Flow Rate Characteristics AS2201F-G02-m, AS2211F-G02-m AS2301F-G02-m, AS2311F-G02-m AS2201F-02-mPA, AS2211F-02-mPA AS2201F-G01-m, AS2211F-G01-m AS2301F-G01-m, AS2311F-G01-m AS2201F-01-mPA
Conductor size (mm2) Overall diameter (mm) Colour of cover SMC product No. (1 pc.) 0.8 to 1.0 Red ZS-28-C 26-24 0.14-0.2 1.0 to 1.2 Yellow ZS-28-C-1 (28) (0.08) 1.2 to 1.6 Orange ZS-28-C-2 1.0 to 1.2 Green ZS-28-C-3 22-20 0.3-0.5 1.2 to 1.6 Blue ZS-28-C-4 1.6 to 2.0 Gray ZS-28-C-5 Do not cut the insulator.
900 m 400 m 160 m 100 m Maximum extended cable length Lower level bus Number of branches for input/ output 4 branches for input 4 branches for output Put Claw 1 of the body under DIN rail and push it upward.
P a ] [ M P a ] PF3W540 PF3W511() [ M P a ] [ M P a ] PF3W521() [ M P a ] -33No.PF-OMN0009CN-F PF3W511(PVC ) PF3W521(PVC ) [ M P a ] [ M P a ] -34No.PF-OMN0009CN-F PF3W504/520/540 PF3W504S/520S/540S [MPa] [MPa] [ M P a ] [ M P a ] a] [MP a] [MP PF3W511() PF3W521() PF3W511/521(PVC ) [MPa] [ M P a ] [ M P a ] a] [MP [MPa] a] [MP -35No.PF-OMN0009CN-F IN 3F.S.8 cm (100 L/min 11
Note 7) The sensor unit conforms to the CE mark. 1.0 Operating pressure [MPa] PF2D 504/520 0.5 PF2D 540 20 40 60 80 100 0 90 45 Fluid temperature [C] Digital Flow Switch Series PF2D For Deionized Water and Chemicals How to Order Remote Type Display Unit PF2D3 A 0 M 0 Unit specification Nil M With unit switching function Fixed SI unit Output specification 0 1 NPN open collector 2 outputs
5.0 kg *1 Depth 160 mm Rc2 Face to Face 170 mm Improved Nominal Filtration Rating AFF 1 m (Current model: 3 m) AM 0.1 m (Current model: 0.3 m) *1 For AFF/AM/AMD90 CAT.ES30-17B AFF/AM/AMD Series Compressed Air Preparation Filter AFF/AM/AMD Series Variations A model with 11.0 m3/min flow capacity (Size 80D) has been newly added.
Cannot be used with M: Round pressure gauge (with color zone). Available by request for special.
(between FE and all accessible terminals) Insulation resistance 10 M ohm or more (500 VDC is given between FE and all accessible terminals) Ambient temperature Operation: -10 C to 50 C Storage: -20 C to 60 C Ambient humidity 35% to 85% RH (non-condensing) 10 Hz to 57 Hz (constant amplitude) 0.75 mm 57 Hz to 150 Hz (constant acceleration) 49 m/s2 2 hours for each direction X, Y and Z (complies
2-A 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 2-B 2-B 1-A 1-B 1-C 2-A 2-B 1-C 2-A 2-B 2-B 2-B 2-B 2-B 1-A 1-B 1-C 2-A 2-B 2-B 2-B 2-B 2-B 2-B CE2 6 1/8, 1/4 1.5 500 0 1,000 2,000 3,000 ML2B Max. speed Vmax (mm/s) 6 1/4, 3/8 3 1000 Graph 3:25 ML1C 10 1/4, 3/8 20 (1/4) 4.5 1500 20 10 1/4, 3/8 REA Composed effective area So (mm2) Composed effective area So (
C Q + Stroke Shock absorber Shock absorber RB0805 Side plate Section IF (CY1L6) (mm) A B D d C EA FA EB Model G HP J JK FB GP H HB HG HI HO HS HT HA CY1L6 CY1L10 7.6 8 3 6.5 7 M4 x 0.7 6 26 6.5 36 27 10 11 9 25 14 16 5 12 10 4 8 8.5 M5 x 0.8 6 3 12 7.5 33 9.5 5 50 34 17.5 14.5 13.5 33 21.5 18 6 PA (N) (NA) (NB) RW Q Z W tb ta T PB MM NN M L QW LD Model CY1L6 CY1L10 TT PW 12 54 68 56 10
Item Display Content [Std] Standard condition [rEF] Selection of reference condition [nor] Reference condition Standard condition: In dry air with a temperature of 20 C and absolute pressure of 101.3 kPa Reference condition: In dry air with a temperature of 0 C and absolute pressure of 101.3 kPa Press the SET button to set.
MHK2-20S MHK2-20C 80 60 70 50 Holding force (N) Holding force (N) 60 Allowable moment Pressure 0.6MPa 50 40 Model Allowable moment Pressure 0.6MPa Nm 40 0.5MPa 30 0.5MPa 0.05 MHK2-12S, C 30 0.4MPa 0.4MPa 0.12 MHK2-16S, C 20 20 0.3MPa 0.25 MHK2-20S, C 0.3MPa 10 10 0.49 MHK2-25S, C 0 0 20 40 60 80 20 40 60 80 M: Allowable moment (M = WL) Holding point L(mm) Holding point L(mm) W MHK2-25S MHK2
(betwen lead wire and case) 10-60'c IEC Slandad, wabniqht(JlS C@m)and oil rsistins slrucure x "L js added to lhe end when tne lead wire is 3m lonsAuto Switch Internal Circuit Auto Switch W Table D-273 49 52 49 7.5 8-5 9.5 xReter to back cols for details ol the speciication of t l 13 contact protction bo)C Compact Guide Cylinder:Series MGQ Auto Switch 2 wire system 24VDC relay, Sequence contoller
(betwen lead wire and case) 10-60'c IEC Slandad, wabniqht(JlS C@m)and oil rsistins slrucure x "L js added to lhe end when tne lead wire is 3m lonsAuto Switch Internal Circuit Auto Switch W Table D-273 49 52 49 7.5 8-5 9.5 xReter to back cols for details ol the speciication of t l 13 contact protction bo)C Compact Guide Cylinder:Series MGQ Auto Switch 2 wire system 24VDC relay, Sequence contoller
Non-rotating rod type C76 Pin cylinder Series C(D)JP 20-CJP Double acting C85 20-CJP Single acting C95 Large bore size cylinder Series C(D)S1 CP95 20-CS1N Standard type NCM Cylinder with lock Series C(D)NA NCA 20-CNA Standard type DCylinder with end lock Series C(D)B 20-CBM2 Standard type -X 20-CBA1 Standard type 20Plate cylinder Series M(D)U 20-MU Standard type Data 20-MUW Double rod type
Approx. 300 V D Approx. 280 D F Approx. 300 F Q Q Class H coil Broken line section C C G 1/2 R R E E A H A H B B 2-P Port size 2-P Port size 2-M, thread depth N 2-M, thread depth N L L K K DIN terminal: D Conduit terminal: T Cable 6.8 to 10 F S Q 27.5 (Q) D F 25 C R C (44) R R E G 1/2 E G 1/2 A H D (S) B B A H 2-P Port size 2-P Port size 2-M, thread depth N 2-M L L K K N.C. dimensions (mm
Basic setting mode Main menu Alarm display menu Maintenance notif Power supply ON Circulating fluid outlet temperature Circulating fluid set temperature 200 ALm mANT 200 XXALM MENU MENU MENU / / / M no (N M circulating fluid return temp AL01 mT01 212 Alarm number (Alarm number minimum RET TEMP / / / M n mT02 AL02 014 Alarm number Circulating fluid outlet pressure PRESS / 79 Circulating fluid
If using straight entry piping type, the material of piping and tubing need to be taken into consideration when deciding panel cut-out spacing. -83No.PF-OMO0005-F Bracket (ZS-33-M) Bracket (ZS-33-MS) Lead wire with connector (ZS-33-D) -84No.PF-OMO0005-F Revision history A: Modified errors in text. B: Revision. C: Contents revised in several place. D: Contents revised in several places.