Stroke 30 30 40 Bore size (mm) 50 63 80 Model 24 24 23 Nil Rc 1/8 Rc 1/4 Rc 1/4 TF G 1/8 G 1/4 G 1/4 RS1H50 RS1H63 RS1H80 Note 1) Dimensions with auto switch are identical to the above.

1 4 KAL06-U02 11.4 11.4 10 15 Uni thread 24.5 23 17 12 1 8 1 4 KAL08-U01 KAL08-U02 25.5 26 22.5 24.5 11 16 14 15.2 8 12 23 18.5 14.9 14.9 3 8 KAL08-U03 17 25.5 27 24 1 8 KAL10-U01 29.5 27 26.5 25 25 21 24 14.9 14.9 1 4 3 8 KAL10-U02 KAL10-U03 30 30.5 17 10 26.5 18.5 17 21 25.0 25.0 1 2 KAL10-U04 30 31.5 45 23 27 22 1 4 3 8 KAL12-U02 KAL12-U03 27 28 31.5 32.5 17 12 20.9 17 28.5 22 39.7 39.7

When equipped with system 2, there are four supply ports, A through D. 32 Air supply ring 24 24 21 Air supply unit body 12 Rc(PT)1/8 Air supply port (plug) 32 IN IN 64 52 (Min. 29) 42 (Min. 29) Supply block unit OUT 342 (Min. 316) + Stroke Air supply ring Air supply unit circuit diagram Rc(PT) 1/8 Air supply port 110 12 2-Rc(PT)1/8 Stroke end air supply port (64) 34.5 32 12 65.5 9

CG1N63-PS CG1N80-PS CG1N100-PS Content Flat nickel plated Carbon steel Rolled steel Steel wire Felt Rolled steel Carbon tool steel End bracket Flat washer Spring washer Felt Holder 19 20 21 22 23 24 Nickel plated Not required for 100 A set of the above nos. 36, 37, 38 Nickel plated Seal kits are sets of items 36 through 38, which can be ordered using the seal kit number for each bore size

R P R R P R L (10) 8 End plate side End plate side (24) (35) 5.5 Silencer with One-touch fitting This is a silencer which can be attached to the R (exhaust) port of a manifold using a One-touch fitting. Rail mounting hole pitch 12.5 C 9 8 7 6 5 4 3 2 1 0 No.

Cable: 3 core 24 x AWG White: B side solenoid ( ) (not used for single solenoid) For different lead wire lengths, order a lead wire assembly with connector shown in the table on the right. Note) There is no polarity. It can also be used as a negative common.

36.5 13.5 15 32 25 23 M5 24 59 46 57 60 54.5 48.5 101 57 68 1/2 22 45 89 41 11 17 36 22.5 23 M5 26 64.5 48 62.5 62 60 50.5 103 62.5 70 1/4, 3/8 VCW41 30 50 93.5 41 13.5 17 36 25 23 M5 26 66.5 48 64.5 62 62 50.5 103 64.5 70 1/2 35 60 101 41 17.5 17 36 30 28.2 M5 26 70 48 68 62 65.5 50.5 103 68 70 3/4 4 Direct Operated 2Port for Water Series VCW Dimensions (N.O.)

Air, inert gas Fluid 0.6 MPa Maximum operating pressure 0.3 MPa Minimum operating pressure 5 to 50C Ambient and fluid temperature Not required Lubrication Manual override Non-locking push type / Lock type (tool type) Push-lock type Non-locking push type / Lock type (tool type) Rated coil voltage DC12, 24 V DC12, 24 V, AC100, 110, 200, 220 V DC 1W 1W 0.5W 100 V AC 0.6VA (6mA) 0.5 VA (5 mA)

Supply 24 V DC 10% for interfaces from outside. Set the total current capacity to 300 mA. 300 mA is the value applicable when all I/O signals are used. The current capacity can be decreased by reducing the number of I/O points. The illustration of the 24 V DC power supply is divided between input signal and output signal for convenience. However, they can be configured by one. 11.

Recommended Parameter Values [LEF] LEFS25 LEFS32 LEFS40 Lead symbol H A B H A B H A B Series Lead 20 12 6 24 16 8 30 20 10 Parameter *1,*2 Para. Initial value Recommended value No.

Number of bytes in Byte count of response data = 8 bytes response data 7 8 8 0 Alarm 1 9 0 Alarm history 1 (Temperature error: 10 0 0003) 11 3 12 Alarm 2 0 (Return to Origin 13 0 Alarm history 2 position non14 0 execution error: Data 15 B 000B) 16 0 Alarm 3 17 0 Alarm history 3 (Origin parameter 18 0 error: 0006) 19 6 20 0 21 0 Alarm 4 Alarm history 4 (No alarm: 0) 22 0 23 0 Calculated 24

IO-Link 1.0 IO-Link -85No.PS-OMV0008CN-E ISE70G ISE75G ISE76G ISE77G ISE78G 01.000 MPa 02.000 MPa 05.00 MPa 010.00 MPa 016.00 MPa / -0.1051.050 MPa -0.1052.100 -0.255.25 -0.5010.50 MPa -0.8016.80 MPa MPa MPa / 0.001 MPa 0.01 MPa 3.0MPa 5.0 MPa 12.5 MPa 30 MPa 48 MPa DC12~24 V1010% IO-Link DC1830 V (p-p)10 35 mA 2% F.S.1 digit(253 ) 0.5F.S. (25 ) 3F.S. 5F.S.


This controller is designed with a separate control power supply (C 24 V) and motor power supply (M 24 V) to enable the aforementioned emergency stop circuitry to be configured.
If you do not plan to configure the emergency stop circuitry as described above, you can use the same power supply for the control power supply (C 24 V) and the motor power supply (M 24 V).

Main circuit N.C. +12 to 24 VDC + CH1_OUT2 (White) DC (+) CH2_OUT1 (Gray) Sensor input: +1 to 5 VDC DC () CH3_OUT1 (Orange) N.C. Bring the pressure back to atmospheric pressure and use the reset function (zero point adjustment) again. CH4_OUT1 (Pink) DC (+) Sensor input: +1 to 5 VDC DC () DC () (Blue) N.C.

Piping port) 24 21 2 x 1.3 (Breathing port) 32 3 position closed center/exhaust center/pressure center SYJA5 20-M5 3 position closed center/exhaust center/pressure center SYJA5 40-01 3 4 5 3 4 5 2 x 4.3 (For mounting) 37.5 4 2 x M5 x 0.8 (Pilot port) 22.6 37.4 M5 x 0.8 (Pilot port) 1 A B 11 B A 5 1 24 1 A B 10 M5 x 0.8 (A, B port) 2 x 2.6 (For manifold mounting) 1 P R 19 42.6 17.4 70 47.6

L* N x 4 N x 8 N x 12 N x 6 N x 12 N x 18 N x 8 N x 16 N x 10 N x 20 N x 12 N x 24 D 18 28 28 24 37 37 31 42 52 52 67 67 TCU0425-1N-X6 TCU0425-2N-X6 TCU0425-3-N-X6 TCU0604-1-N-X6 TCU0604-2-N-X6 TCU0604-3-N-X6 TCU0805-1-N-X6 TCU0805-2-N-X6 TCU1065-1-N-X6 TCU1065-2-N-X6 TCU1208 -1-N-X6 TCU1208 -2-N-X6 LX5.9 + 200 LX4.4 + 200 LX2.9 + 200 LX5.3 + 200 LX3.8 + 200 LX2.5 + 200 LX5.2 + 200 LX3 +

When twenty-four (24) 3 port valves are used, specify 24. Specify twelve (12) stations for manifold. To fill in the blanks in the manifold number, please refer to symbols in catalog. Select the valve referring to the specification table. Manifold C C 1 V V V C C 1 0 0 Valve Pilot port piping size Upper table is for 2 port valve. Lower is for 3 port valve.

102 4.4 4.4 1P 3EB 3EB 1P 5EA 5EA 4.4 1/4, 3/8 [1(P), 5 (EA), 3 (EB) port] 1/4, 3/8 [1 (P), 5 (EA), 3 (EB) port] 52 52 3 position closed center/exhaust center/pressure center VFA5 20(-P) 02 03 3 4 5 138 59.5 (78.5) 66 47 (28.2) (Distance between ports) 4A 24 32 3 2B 1/8 (Pilot port: Upward) 28 2 x 4.3 (For mounting) 1/4, 3/8 [4 (A), 2 (B) port] 44 1/8 [Pilot port: Lateral (-P)] 36 4.5 45

Fixed end Translucent (N) Air Fluid Max operating pressure (at 20C) Burst Pressure Characteristics Curve and Operating Pressure 1.0 MPa 5 Min. bending radius (mm) 10 18 24 30 36 4 Burst pressure (MPa) Refer to the burst pressure characteristics curve.

D-S791/S792 2.11-24 D-T791/T792 Direct mounting 2.11-24 D-S7P1/S7P2 MHC2 Connector 2.11-24 D-T791C/T792C MHT2 D-F9N/F9P/F9B D-F9NV/F9PV/F9BV D-Y59A/Y59B/Y7P D-Y69A/Y69B/Y7PV 2.11-25 Grommet MHY2 2.11-26 Grommet Rail 2.11-27 D-F79W/F7PW/J79W MHW2 D-Y7NW/7PW/7BW D-Y7NWV/7PWV/7BWV Water resistant 2 color indication With diagnosis output 2 color indication 2.11-28 Direct mounting MRHQ Grommet