C P J M N H K O L mm A B C D E F G H J K L M N O P IDFA60 R1 307 745 605 161 405 681 94 71 46 12.5 330 704 355 126 IDFA70 R1-1/2 342 890 825 176 480 905 68 365 849 390 81 20 IDFA80 R2 438 957 863 169 480 958 219 78 100 11.0 463 916 485 170 IDFA90 13 IDFA80 IDFA90 mm IDFA60 745 957 () () 704 916 () () 355 330 485 463 IDFA70 890 () 849 () 390 365 IDFA60/70/80/90 Series 7-3 IDX-OM-W094 7.4
Blue DC() -26 Analog output type 1 to 5V (2.5% F .S.) Output impedance: 1k Bring the pressure back to atmospheric pressure and try using the zero out function. Residual pressure error Brown DC(+) Black OUT (Analog output) + 12 to 24VDC Load Blue DC() Supply pressure exceeds the maximum regulating pressure. -28 Analog output type 4 to 20mA (2.5% F .S.)
F (E) L H G F E B M L 28.5 34.5 47.5 52.5 64 78 11 16 21 24 32 41 9.5 12 18 20 28 36 4.8 6 9 10 14 18 10 17 22.5 24.5 27 30 3.5 4 5 6 7 8 14 20 25 29 37 49 1/8" 1/4" 3/8" 1/2" 3/4" 1" LQ3T1A LQ3T2A LQ3T3A LQ3T4A LQ3T5A LQ3T6A M 1/4 (E) (E) G H L L Panel Union : LQ3P J Panel Thickness (Max. t) (mm) Inch Size H W2 W1 Model Tubing O.D.
Flow Rate and Effective Area VR1211F Model 6 4 3.2 Metric size Applicable tubing O.D. 1/4" 5/32" 1/8" Inch size Flow rate l/min (ANR) 170 150 120 100 INOUT 2.6 2.3 1.8 1.5 Effective area mm Note 1) Flow rate values are at a pressure of 0.5MPa and temperature of 20C.
C P J M N O L K H mm A B C D E F G H J K L M N O P IDF60 R1 307 745 605 161 405 681 71 330 704 355 126 46 12. 94 5 IDF70 R1-1/2 342 890 825 176 480 905 68 365 849 390 81 20 IDF80 R2 438 957 863 169 480 958 219 78 100 11. 0 463 916 485 170 IDF90 13 IDF80 IDF90 mm IDF60 745 957 () () 704 916 () 355 () 330 485 463 IDF70 890 849 () 390 365 IDF60/70/80/90 Series 7-3 IDX-OM-W093 7.4 IDF60/70
C P J M N H K O L mm A B C D E F G H J K L M N O P IDFC60 R1 307 745 605 161 405 681 71 330 704 355 126 94 46 12.5 IDFC70 R1-1/2 342 890 825 176 480 905 68 365 849 390 81 20 IDFC80 R2 438 957 863 169 480 958 219 78 100 11.0 463 916 485 170 IDFC90 13 mm IDFC80 IDFC90 IDFC60 745 957 () () 704 916 () 355 () 330 485 463 IDFC70 890 () 849 () 390 365 IDFC60/70/80/90 Series 7-3 IDX-OM-W095 7.4
C P J Unit: mm M N O L K H Unit: mm Model Port Size A B C D E F G H J K L M [N] O P IDFA60 R1 307 745 605 161 405 681 71 330 704 355 126 94 46 12.5 IDFA70 R1-1/2 342 890 825 176 480 905 68 365 849 390 81 20 IDFA80 R2 438 957 863 169 480 958 219 78 100 11.0 463 916 485 170 IDFA90 Anchor bolt location Hole diameter:13 Unit: mm IDFA80 IDFA90 IDFA60 745 (957) (Air dryer outside) (Air dryer outside
The ZSE40A(F) is also CE, UL/CSA and RoHS compliant.High precision digital pressure switch w/2-color display , IP65 and RoHS compliant , Capable of copying up to 10 switches simultaneously , 3-step setting , Space saving design w/several piping and mounting variations, Digital Pressure Switch 5M Lead, VACUUM SWITCH, ZSE40, ZSE40A, M58, 100 lb
Magnet: D (Built-in), Mounting: F (Front Flange), Size: 50 (Pressure Receiving Area Equivalent to that of ø50 Type), Thread: TN [NPT Threads (ø32, ø40, ø50)], Stroke: 250mm, Rod End: M (Rod End Male Thread), Locking Direction: F (Forwarding Stroke Lock), Auto Switch: A73H--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Horizontal, 0.5M
Magnet: D (Built-in), Mounting: F (Front Flange), Size: 50 (Pressure Receiving Area Equivalent to that of ø50 Type), Thread: TN [NPT Threads (ø32, ø40, ø50)], Stroke: 250mm, Rod End: M (Rod End Male Thread), Locking Direction: F (Forwarding Stroke Lock), Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, 0.5M
Magnet: D (Built-in), Mounting: F (Front Flange), Bore Size: 50mm, Thread: M5x0.8 (20-25 Bore); Rc (32-100 Bore), Stroke: 35mm, Body Option: C (Rubber Bumper), Locking Direction: F (Forwarding Stroke Lock)
Magnet: D (Built-in), Mounting: F (Front Flange), Bore Size: 63mm, Thread: M5x0.8 (20-25 Bore); Rc (32-100 Bore), Stroke: 100mm, Body Option: Standard, Locking Direction: F (Forwarding Stroke Lock)
UL certified for use in North America; 60 Hz operation; Max. inlet air temperature: 122°F (50°C); Max. flow at rated conditions: 300 scfm 510m³/hr (ANR) @37°F (3°C) PDP; Connections: NPT threads are standard; R/Rc adapters are available
The MLGP* - B/F is a compact body, locking actuator integrated with internal guide shafts to isolate the load bearing from the movement of the actuator's rod and seals. The locking mechanism can be specified for either the extension side (F) or the retraction side (B) of the stroke.
Flow ranges (lpm): 0.2-10, 0.5-25, 1-50, 2-100; Port sizes: 1/8 or 1/4 (Rc, NPT, G); ø6 or ø8 one-touch fittings; Rated pressure range (MPa): -0.07 to 0.75; Output options: 1-5V or 4-20mA; Accuracy: ±3% F. S.; Repeatability: ±1% F. S.
LEY*F is a high performance version of the standard rod actuator, suitable for push, pull, lift and press applications. Cycle time is dramatically reduced by a combination of higher maximum speed and acceleration/deceleration. Speed gains are 20-60% faster, depending on motor size, ballscrew pitch, and stroke.
LEY*F is a high performance version of the standard rod actuator, suitable for push, pull, lift and press applications. Cycle time is dramatically reduced by a combination of higher maximum speed and acceleration/deceleration. Speed gains are 20-60% faster, depending on motor size, ballscrew pitch, and stroke.
LEY*F is a high performance version of the standard rod actuator, suitable for push, pull, lift and press applications. Cycle time is dramatically reduced by a combination of higher maximum speed and acceleration/deceleration. Speed gains are 20-60% faster, depending on motor size, ballscrew pitch, and stroke.
The MLGP-B/F is a compact body, locking actuator integrated with internal guide shafts to isolate the load bearing from the movement of the actuator's rod and seals. The locking mechanism can be specified for either the extension side (F) or the retraction side (B) of the stroke.
UL certified for use in North America; 60 Hz operation; Max. inlet air temperature: 122°F (50°C); Max. flow at rated conditions: 300 scfm 510m³/hr (ANR) @37°F (3°C) PDP; Connections: NPT threads are standard; R/Rc adapters are available