SMC Corporation of America
Elite Part Number Search
Search Results "SS5Q13-04LD1-E"

CKQPUA50 The below figures indicate the CKQPUA50-RAL. w e w e r r !4 !4 !5 !5 @8 @9 @9 #0 @8 @7 Theres no seal kit for CLKQPUA50. Theres no seal kit for CLKQGUA50. The numbers are the same as the "Construction" of the Best Pneumatics No.3 Series CKQU/CLKQU. The numbers are the same as the "Construction" of the Best Pneumatics No.3 Series CKQU/CLKQU.

-B 40 W 50 L/min 1000 Hz 0.55 0.4 High speed response required for both ON and OFF -E 80 W 100 L/min 650 Hz 0.55 0.55 -F 40 W 100 L/min 550 Hz 0.7 0.55 -J 80 W 150 L/min 600 Hz 0.6 0.75 -K 40 W 150 L/min 500 Hz 0.8 0.75 * Current needs to be limited.

: 32C, w Circulating uid: Tap water, e Circulating uid ow rate: Rated ow, r Power supply: 200 VAC 4 q Ambient temperature: 32C, w Circulating uid: Tap water, e Circulating uid temperature: CH1 20C/CH2 25C, r Load: Same as the cooling capacity, t Circulating uid ow rate: Rated ow, y Power supply: 200 VAC, u Piping length: Shortest 5 With the pressure control mode by inverter.

JAS Series How to Order Port size M3 M3 x 0.5 M5 M5 x 0.8 U10 10-32UNF JAS L E A 04 M5 JAS L E A S 04 01 Seal method Type L Elbow Nil Without sealant S With sealant Control type1 Port size E Meter-out S Meter-in 01 1/8 1 Meter-out and meter-in types can be visually identified by the color of the knob.

: With lead wire (Length 300 mm) MN: Without lead wire WO: Without connector cable M: Common exhaust for the pilot and main valve + + + + D: Push-turn locking slotted type R port P, E port H: Lead wire length 600 mm Pilot valve exhaust is centralized to main valve.

Brown DC (+) OUT 1 OUT 2 OUT 3 OUT 4 OUT 5 GND VCC NC OUT 6 L side R side Load Black OUT Main circuit + 12 to 24V DC MAX.80mA PSE Blue DC () ZSE4 ISE4 ZSE5 ISE5 PNP Open Collector (Sourcing) ZSE6 ISE6 Brown DC (+) q w e r t y ZSE3 ISE3 Main circuit 12 to 24V DC MAX.80mA + Black OUT GS Load Blue DC () PS ISA Precautions ZSE1 ISE1 Be sure to read before handling.

Cable connector (4 wire) Right angle type Cable connector (4 wire) Straight type n50 4-7 Mounting hole 31 SMC PREGULATOR E SMC PREGULATOR E RESET 40 52 ITV2090 ITV2090 SET UNLOCK LOCK 84 100 12.5 M12 x 1 Cable connecting threads 1.6 12 (99) (11) SMC PREGULATOR E ITV2090 Rc 1/4 VAC port G OUT 2 ATM (Atmospheric pressure) OUT (Set pressure) VAC (vacuum pressure) 19 n36 Flat bracket P3020114

CM01-8DP4S DDK Ltd. 10 Series PF2A Dimensions PF2A703H, 706H, 712H D E Internal circuits and wiring examples to are terminal numbers.

IS400-1 (1S-1) IS400-2 (1S-2) Model Port size B C D E F G H I J A , 1 4 1 2 1 1 AL800-12 to 14-1 AL900-20-1 431 (481) 437 (487) 3-M5 x 0.8 x depth 6 3-M5 x 0.8 x depth 6 230 230 ( ): With float switch 117 117 60 60 100 100 2 59 63 166 162 73 73 14-13-5

ALD600 ALD900 12612AP Check valve assembly Pilot body assembly e r Maintenance 12609AP Warning Glass fiber-inserted epoxy resin t Bowl assembly 126139-1A 126059-1A 1. Before removing the oil filler plug, loosen it two and a half turns to completely release the pressure inside the case.

Inlet pressure (MPa) Weather resistant NBR Diaphragm assembly e 1315510A Flow Characteristics Inlet pressure: 0.7 MPa Valve assembly Valve spring Valve mini Y packing O-ring O-ring Handle Set nut Brass, HNBR Stainless steel NBR NBR NBR Polyacetal Zinc die-casted r t y u i o !

0 e New PFA q Body New PFA w Sensor Super PFA e Tube PPS r Housing A PPS t Housing B PPS y Housing C POM u Bushing PPS i Cap FKM o Gasket FKM !0 O-ring Stainless steel 304 !1 Thread PVC !2 Lead wire !1 q t i PF2D540 o !0 u !0 !2ywr e !

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VX3 VXA VN LVC Component Parts LVA LVH q w e r t y LVD LVQ 66 LQ Solenoid Assembly Part No. LVN TI/ TIL VXF 2150 1 G 00 PA Electrical option Model Port size Nil S L Z 3 4 3 3 ' 4 PAX 2150 2160 2280 5', ! ! !'

If the leakage volume is 30 /min (ANR), the vacuum pressure of the S type is 20 kPa q w e, and for the L type it is 33 kPa q' w' e'. If the leakage volume is 5 /min (ANR), the vacuum pressure of the S type is 80 kPa r t y, and for the L type it is 47 kPa r' t' y'.

Range Back Pressure SMC 22 8.0 -750mmHg~58psi 0~100C 0~30psi (60psi) 136 150 75 Height Width Operator Dia. 1 LVQ60 LQ Seal Locations N u t S e a l L o c k T ubing Support T aper Surface T u b i n g T r ap e zoidal T h re a d s I n s e rt Bushing Nut Lock U.S. Patent #5,996,636 Quadruple Seal Maximum leak protection. Up to 215psi @ 200C.

Models Symbol (A) 2 Effective area mm (Cv factor) Operating pressure range MPa {kgf/cm} Port size Valve model Weight g (grommet type) VKF33 3.6 (0.2) 2 3 0 to 0.7 {0 to 7.1} VKF33 Y (for low power consumption, DC2W) 2.7 (0.15) 2 3 3 (R) 1 (P) Note 1) M5 x 0.8 Rc(PT) 1/8 Body ported VKF33 E (for long loading time) 2.7 (0.15) 80 2 3 VKF33 V (for vacuum) 3.6 (0.2) 2 3 101.2kPa to 0.1 {1Torr

Description q w e r t y Note Body Valve cover Adapter plate Cover Tension bolt Flow adjustment screw AMJ Misc. ZMA-HCB Electroless nickel plated Replacement Parts No. Description u i o !0 !1 !2 Part no.

. @ 690 kPa llOO p6i): 45ON tlOolbl with x-ht-2:1 optbn: gooN (2mtb) -5o: somm 11.97"1 Sr6ke 150: 150mm {5.905"1 Weiqhl -50: 4.6k9 ilo 2b) Weight 150: 5.2k9 111.3bl Max Presure: 1,7OOkP8 (25O psD 1 6 N E M d t h v e s E A D p | . d F i a .150N ( l00lbs xRAY-450-50 XRAY-450-50-POB i50N (l(l0lbst xRAY-450150 450N ( lOOlbs xRAY-450150-POB XRAY-450-50 Weld Spatter Covers x-cov-450-50 xRAY-450

Series: SS5Y3 (SY3000 Manifold), Model: 10S6 (Side-Ported, Serial Interface, EX600), SI Unit: 0 (w/o SI Unit), SI Unit Common, End Plate: w/o SI Unit, I/O Unit Stations: None, Valve Stations: 5 Stations, P,E Port, SUP/EXH Assembly: E (Port Location D Side, Internal Pilot, Built-in Silencer), A,B Port Size: N1 (ΓΈ1/8" One-touch Fitting), Mounting: D (DIN Rail Mounting w/o Name Plate), DIN Rail